The SALUS Quantum WQ610 and WQ610RF thermostats are Boiler Plus compatible thermostats, designed specifically to control central heating boilers and in the case of the RF versions, electrical panel heaters also. They have our new load compensation (ITLC) software with Volt free switch and also Opentherm 4.0 connections, so you can choose the method of control to suit your boiler / installation. Please note that the Boilers need to have an OpenTherm Association license to be fully compatible with WQ610 range (should you wish to connect to the OpenTherm terminals A and B). Please verify if this requirement is met with your Boiler Manufacturer.
This product complies with the essential requirements and other relevant provisions of the following EU Directives: RED:2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is available on: www.saluslegal.com WQ610RF: 2.405-2480MHz; <14dBm
Use in accordance with national and EU regulations. Use the device as intended, keeping it in a dry condition. Product is for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.
WARNING! Always ensure the AC mains power is switched off before installing or working on any components.
WQ610 Thermostat | WQ610RF Thermostat | |
Thermostat supply | 230V AC | Lithium Battery (Rechargable) |
Thermostat rating max | 3 (1) A | – |
OpenTherm terminals | A / B | – |
Outputs | Voltage free NO / COM terminals | – |
Temperature range | 5°C – 35°C | 5°C – 35°C |
Thermostat display accuracy | 0.5°/0.1°C | 0.5°/0.1°C |
Thermostat display resolution | 0.5°C | 0.5°C |
ErP control class | Class V | Class V |
Radio Frequency | — | 2.4 GHz |
Dimension [mm] | 86 x 86 x 27 [mm] | 86 x 86 x 11[mm] |
WQ610 Receiver | ||
Receiver supply | 230 V AC | |
Receiver rating max | 16 (5) A | |
OpenTherm terminals | A / B | |
Outputs | Voltage free NO / COM terminals | |
Radio frequency | 2.4 GHz | |
Dimension [mm] | 98 x 98 x 32[mm] |
The pairing between the thermostat and the receiver is already done at the factory. However, should you need to re-pair the units then this can be done using the User Menu. The link may also be tested from the User Menu to show pairing link has been successful. Before pairing, the receiver should be unplugged, then plugged back in. During the pairing process, the distance between the Thermostat and the receiver should be at least 1m.
In this mode, the user can set the schedules for the thermostat (temperature setpoints for specific periods of time). Programmed schedules should use all time periods.
TIME: | TEMPERATURE: |
06.00 | 21 °C |
10.00 | 14 °C |
12.00 | 21 °C |
14.00 | 14 °C |
18.00 | 21 °C |
21.00 | 14 °C |
This is an example for your weekly schedule. High temperature should be used for the ON times and low temperature for the OFF times.
For overriding the schedule to bring the HEAT on, use the UP button to increase the temperature and press TICK to confirm.
Note: This setting will be valid until the next scheduled program.
FACTORY RESET will require PIN code if locked.
Head Office:
SALUS Controls Units 8-10
Northfield Business Park Forge Way Parkgate Rotherham
S60 1SD
Email: sales@salus-tech.com
www.salus-controls.com
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change the specification, design and materials of products listed in this brochure without prior notice.
Issue Date: June 2021
Download Manual
SALUS WQ610RF THERMOSTAT Quick Guide
Other manuals
SALUS WQ610RF THERMOSTAT User Manual
SALUS WQ610RF THERMOSTAT Installation Guide
SALUS WQ610RF Wireless Slim Programmable Thermostat technical Specification Guide
SALUS WQ610RF 230V Wireless Slim Programmable Thermostat technical Specification Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…