SALUS WQ610RF THERMOSTAT
Introduction
Product Compliance
This product complies with the essential requirements and other relevant provisions of Directives 2014/53/EU and 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com.
Safety Information
- Before starting installation work and before using the product, read the entire manual.
- The information contained in the instructions is essential for proper functioning.
- To avoid accidents resulting in personal injury and material damage, please follow all safety precautions, specified in this manual.
- The device should not be used by people with limited mental, sensory or mental abilities, without experience, of insufficient knowledge as well as children.
- Do not use an unassembled device (eg without a cover).
- The device may only be opened by a qualified person.
- Keep electrical devices out of the reach of children and ensure that they do not play with it. Children should not be left unattended. If necessary, disconnect the control system for the entire room.
- Do not leave the packaging, cabinet, or any loose parts of the device unattended, as they pose a risk to children.
WARNING
- Installation must be carried out by a qualified person with appropriate electrical qualifications in accordance with standards and regulations in force in the given country and in the EU.
- Never try to connect the device other than as described in the manual.
- Before assembly, repair or maintenance as well as during any connection works it is absolutely necessary to disconnect the mains supply and make sure that the terminals and electric wires are not live.
- The device may not be exposed to extreme temperatures, strong vibrations or subjected to mechanical shock.
- The device should not be used in unfavorable environmental conditions or in rooms where there is a concentration of flammable gases, fumes or dust.
WARNING!
- There may be additional protection requirements for the entire installation that the installer is responsible for maintaining. Care for the natural environment is of paramount importance to us. The awareness that we manufacture electronic devices obliges us to dispose of used electronic components and devices safely. Therefore the company has received a registration number issued by the Chief Inspector for Environmental Protection. The crossed-out symbol of the trash can on the product means that the product must not be disposed of with ordinary waste containers. Sorting waste for recycling helps to protect the environment. It is the user’s responsibility to surrender used equipment to a designated collection point for recycling waste from electrical and electronic equipment.
Product Overview
The RT510RF wireless room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting and switching it off once this set temperature has been reached. Turning a room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of the boiler and radiators. Neither does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy. The heating system will not work if a time switch or programmer has switched it off.
The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature – say 18⁰C – and then turn it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money. If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs. Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, and wall or table lamps may prevent the thermostat from working properly.
PLEASE NOTE!
Make sure your gas combi boiler is compatible with OT + 4.0 communication protocol.
The list of compatible boilers is on the next page.
Product advantages
- the set is factory paired and prepared for operation
- limiting the maximum boiler temperature by OT+ 4.0 protocol
- option to select hysteresis or built-in ITLC algorithm
- works according to time schedules
- has a PIN-protected service mode
- maximum/minimum temperature limit
- can temporarily change the temperature (overwriting until the next program change)
Example of boilers compatible with the OpenTherm OT+ 4.0 protocol
COMPANY | MODEL |
Alpha Heating |
E-Tec S
E-tec Plus E-tec Evoke Intec GS |
Atag |
iC
iC Economiser iS |
Baxi |
100 Combi
200 Combi 400 Combi 600 Combi |
Daikin |
D2CND 24Kw D2CND 28kw D2CND 35kw |
Ferroli | i25 Condensing Combination Boiler i29 Condensing Combination Boiler |
Ideal |
Independent + Combi Independent Combi Independent System Logic Combi+ Combi C
Logic Combi C24, C30, C35 (via a separate bundle set) Logic Code Combi (via a separate bundle set) I-mini C24, c30 (via a separate bundle set) Vogue Combi C26,C32, C40 Logic + System Logic + Heat |
Intergas |
Intergas Rapid Intergas Rapid Plus
Combi Compact, Compact Range ECO RF Xtreme Xclusive |
Main | Eco Compact Combi 25-30 |
Navien | Navien NCB |
Ravenheat |
Avanta, Quinta Ace Quinta Pro
Gas 110 Eco |
Vokera |
Evolve C Evolve S
Linea One (przez OpenTherm Kit Part_1221179) Vision Combi (requires a control interface 294501430 Compact A (requires a control interface 29450143) Verve (only heating mode) Mynute I (only heating mode) Vision System (only heating mode) Unica I Vibe Vision C |
COMPANY | MODEL |
Vokera |
Linea HE Mynute A Mynute HE Unica HE |
Viessmann |
Vitodens 100W Typ WB1A (Connection: X3.3 and X3.4) Vitodens 100W Typ WB1B (Connection: X21.1 and X21.2)
Vitodens 100WTyp WB1C (Connection: X21.1 and X21.2) Vitodens 200-W WB2B 26+ 35 kW (via Expansion Mo- dule OT and OT-A8 + _Terminal -10 and +10 are on the extension of the A8 boiler) Vitodens 200-W WB2C, B2HA,B2JA, B2LA (via icm Expander OpenTherm) |
Vaillant (via Vaillant VR33 module) | Ecotec Pro Ecotec Plus Ecotec Exclusive Ecofit Pure |
Worcester Bosch (via Nefit EMS-OT OpenTherm converter) |
EMS capable boilers Greenstar i
Greenstar i Junior (Made in July 2013) Greenstar Si Compact Greenstar CDi Compact Greenstar CDi Classic (Made after 16.01.2007 with CF12.10 software version and newer) Greenstar Highflow CDi Greenstar 12i System – 24i System (On condition that an optional integrated diverter valve manufactured after February 2011 is installed) Greenstar 27i System – 30i System (Provided the optio- nal Integrated Changeover Valve is installed Greenstar CDi Classic System (provided the optional Integrated Changeover Valve manufactured after 02/16/2007 with software version CF12.10 and above is installed)) |
Package content
- WQ610RF
- WQ610RX receiver
- Short instruction
- Mounting screws
Proper thermostat location
Please note
The ideal position to thermostat mounting is about 1,5m under floor level far from heating or cooling sources. The thermostat can’t be exposed to sunlight or any extreme conditions like for example draft. Because of fire and explosion risk there is not allowed to use the thermostat in an atmosphere of explosive gases and flammable liquids (eg coal dust). In case if any of the listed dangers occur you have to use additional protection measures – anti-dust and explosive gases (tight cover) or prevent their formation. Furthermore, thermostats can’t be used in condensation of water vapor conditions and be exposed to water action.
WQ610RX receiver
The thermostat communicates wirelessly with the WQ610RX receiver. The receiver should be supplied with 230VAC, the maximum load of the receiver is 16A. Avoid installing the device in places directly exposed to water, moisture and air condensation. The WQ610RX receiver can operate in two different modes – AUTO (automatic) and MANUAL (manual). To select a specific mode, use the switches on the front of the receiver.
Receiver’s switches description
Receiver’s switches description
TOP SWITCH | |
1. |
ON – Manual mode – receiver ON |
2. |
OFF – Manual mode – receiver OFF |
BOTTOM SWITCH | |
3. |
AUTO – Receiver works in AUTO mode (according to the thermostat’s command) |
4. |
MANUAL – Receiver works in manual mode (according to the top switch) |
REMEMBER!
For the receiver to work with the thermostat, set the switches to the ON / AUTO position.
LED indications in the receiver
The status of the RXRT510 receiver is indicated by two LEDs. These are LEDs with the following colors:
- red (upper one),
- green (lower one).
A detailed explanation of the meaning of the LEDs can be found in the table below:
DESCRIPTION | |
The red LED lights up |
The receiver is connected to the 230V power supply and is paired with the thermostat.
The receiver can be thermostat-enabled if it is in automatic mode when the lower switch is in the AUTO position. The receiver can be started manually when the lower switch is in the MANUAL position. |
The red LED flashes |
The receiver is in the pairing mode and is looking for a signal from the thermostat (then you must activate the “PAIRING” option in the thermostat)
(or)
The receiver was paired but lost communication with the thermostat due to out of range or low battery in the thermostat. The receiver starts flashing after one hour of time when it does not receive a signal from the thermostat. |
The red diode is off | The receiver is disconnected from the 230V power supply or the upper switch is in the OFF position. |
The green diode lights up |
In automatic mode, the receiver received a heating signal from the thermostat.
The receiver was started in manual mode (upper ON switch, lower MANUAL switch) |
The green diode is off | The receiver does not send a heating signal. |
Wall mounting of the receiver
Wall mounting the receiver: drill two ø6 mm holes in the wall. Insert the plugs and, by putting the plate to the wall (included in the set), put the two screws through the holes and then screw them in. Connect the necessary cables to the receiver. Next, hang the receiver on the board using the handles designed in the receiver, marked in the picture below.
- Loosen the screws with a screwdriver just enough to tilt the back housing.
- Tilt the receiver cover upwards (according to the position of the „hinge”).
- Attach the back housing to the wall (keeping the correct positioning of the plastic „hinges”) using the marked holes (see the picture above).
- Then, correctly connect the wires with the receiver (see „connection diagrams” on page 9).
- Put the receiver from above on the back housing attached to the wall, according to the position of the plastic „hinges”.
- Tighten the screws from the bottom of the back housing to the receiver so that it is snug.
Connection description
Before you start (first power up)
LCD icon description
- Menu/Settings description
- Clock 24hr/AM/PM
- Temperature unit
- Heating indicator (icon is animating when there is heating demand)
- RF Connection indicator
- Advanced settings lock indication
- Current /Setpoint Temperature
- Holiday mode indicator
- Temporary override mode
- Settings icon
- Battery indicator
- Schedule program number
- Schedule mode icon
- Day indicator/ SET information
- MENU – enter the menu options, press and hold for 3 seconds to return to main screen without saving changes.
- DOWN – decrease the temperature and move through the menus.
- UP – increase the temperature and move through the menus.
- TICK – confirm changes and enter menus.
Press and hold for 3 seconds to exit User Menu and save changes. Press and hold to cancel the BOOST feature or temporary override (while in main screen).
Li-on battery charging
New WQ610RF thermostat is partially charged, however, we recommend you to fully charge the battery before use.
Connect charger to micro-USB port which is at the bottom of WQ610RF to charge the device.
First power-up sequence and configuration
Operating
Setpoint temperature change (manual mode)
In manual mode, the thermostat maintains a constant temperature set by the user. A hand icon is displayed when manual mode is active.
Schedule mode – programming schedule
In this mode, user can set the schedules for thermostat (temperature setpoints for specific periods of time). Programmed schedules should use all time periods.
PLEASE NOTE! The thermostat should be set in AUTO mode to work according to the programmed schedule. Please refer to chapter 5.9.
Repeat the process for all time periods.
Temporary override mode
When thermostat is running schedule mode we can temporarily override it by setting new setpoint temperature.
OFF mode
In this mode, thermostat is turned off and maintain frost protection temperature (please refer to 4.6.10 chapter).
Language
To choose language follow steps below:
Advanced settings
In advanced settings user can set eg. temperature calibration, DST or PIN code etc. Remember that these are installer settings!
- DST (Daylight Saving Time) setting
When DST function is ON then thermostat will automatically change time in summer time period. - Display temperature accuracy
Adjust the measured thermostat temperature display scale for about 0,5 °C or 0,1 °C. Please follow steps below: - PIN Code
Set PIN code to lock possibility to control the thermostat until you enter the code. - Service alert
Set a service reminder on the thermostat that will warn the tenant when the boiler is due its annual service. - Optimum Start
The optimization function is an energy-saving algorithm used for efficient control of the heating device, ensuring better thermal comfort at certain times of the day. When the OPTIMUM START function is active, the thermostat sends a heating signal to the heat source beforehand so that the preset temperature in the room is reached at the time specified in the schedule. - Optimum Stop
When the OPTIMUM STOP function is active, the thermostat, taking into account the inertia of the system, switches off the heat source earlier, keeping the temperature set in the schedule. - Thermostat temperature calibration
Thermostat calibration is a function which allows user to recalibrate internal thermostat’s temperature sensor by a given number of degrees (in the range from -3,5 °C to 3,5 °C). To calibrate thermostat’s temperature sensor please follow steps below: - Minimum setpoint temperature
This parameter allows to limit temperature setpoint range by setting minimum setpoint for heating mode. Default temperature setting range: 5⁰C – 35⁰C - Maximum setpoint temperature
This parameter allows to limit temperature setpoint range by setting maximum setpoint for heating mode. Default temperature setting range: 5,5⁰C – 35,0⁰C - Control algorithm
Set control algorithm: ITLC for radiators, SPAN (hysteresis) 0,5°C or SPAN (hysteresis) 0,25°C.
ITLC is a self-learning, time-proportional control algorithm. The regulation of the ITLC type ensures economical operation system due to more precise temperature maintenance during the controlling process In addition to an accurate and stable room temperature, the advantage of this system is the minimization of energy consumption and significant savings.
Hysteresis is the temperature difference between which the thermostat works, keeping the set temperature. For example, if you set the temperature to 20°C and if the hysteresis is ± 0.5°C, the heating will be turned on when the room temperature drops to 19.5°C and turned off when the temperature reaches 20.5°C.
Holiday mode
Holiday mode is a special program temperature setpoint that thermostat will maintain for specified days. During the holiday mode thermostat is maintaining frost protection setpoint temperature. How to set HOLIDAY MODE:
Time/Date
To set a time/date follow the steps below:
BOOST hours – hourly temperature override
The function is available only in AUTO and OFF modes. Used to change the temperature to the desired value for a specified number of hours (up to 9 hours).
After the elapsed time, the thermostat returns to the previous operating mode.
How to stop BOOST mode
Operating mode
Select operating mode for thermostat: Manual mode, AUTO mode or OFF.
WQ610RF thermostat pairing with the receiver
The pairing process takes up to 10 minutes.
WARNING!
IN THE SET WQ610RF THE THERMOSTAT IS FACTORY PAIRED WITH THE RECEIVER!
In order to pair the devices correctly, you must first prepare the receiver for synchronization!
Test the pairing process
It is important to place the receiver and transmitter in places where nothing interferes with the radio signal. The range of communication between the transmitter and the receiver in an open area is up to 60m. The radio transmission is influenced by many factors that can shorten the working distance, such as thick walls, drywall covered with aluminum foil, metal objects such as cabinets, general radio interference, etc. However, the range is sufficient for most domestic use. It is recommended to test the radio transmission between devices before mounting the regulator on the wall. The test can be performed by changing the set temperature, i.e. by activating or deactivating the heating.
Factory Reset
To RESET WQ610RF thermostat to it’s factory default settings please follow steps below:
Error codes
Thermostat will display errors only when it’s connected to the boiler by OPENTHERM terminals (A / B). Please refer then to boiler manual. Each boiler can have different error codes.
ERRORS EXAMPLES:
Cleaning and Maintenance
The WQ610RF thermostat requires no special maintenance. Periodically, the outer casing can be wiped clean using a dry cloth (please DO NOT use solvents, polishes, detergents or abrasive cleaners, as these can damage the thermostat). There are no user serviceable parts within the unit; any servicing or repairs could only be carried out by Salus Controls or their appointed agents.
Technical Informations
Power supply | 230V AC 50Hz |
Receiver rating max | 16(5)A |
Output signal | OpenTherm or COM/NO relay |
Temperature range | 5 – 35°C |
Display temperature accuracy | 0.1°C or 0.5°C |
Control algorithm | ITLC or ±0.25°C or ±0.5°C |
Communication | Wireless, 2.4 Ghz radio frequency |
Dimension [mm] | Thermostat: 86 x 86 x 11
Receiver: 96 x 96 x 27 |
Warranty
SALUS CONTROLS warrants this product to be free from any defects in material or workmanship and to perform as specified for a period of five years from the date of installation. SALUS CONTROLS reserves the sole responsibility for breach of this warranty by repairing or replacing the defective product. This product includes software that matches the distributor’s identification at the time of sale. The manufacturer/distributor provides a guarantee covering all functions and specifics of the product in accordance with this marking. The distributor’s warranty does not cover the correct operation of the functions and features available as a result of a product software update.
The full warranty conditions are available at www.salus-controls.eu
PRODUCER:
Salus Limited 6/F, Building 20E, Phase 3, Hong Kong Science Park, 20 Science Park East Avenue, Shatin, New Territories, Hong Kong
IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k. ul. Rolna 4, 43-262 Kobielice
www.salus-controls.eu
SALUS Controls is a member of the Computime Group. Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change the specification, design, and materials of products listed in this brochure without prior notice.
Reference
Download Manual
SALUS WQ610RF THERMOSTAT User Manual
OTHER MANUALS
SALUS WQ610RF THERMOSTAT Installation Guide
SALUS WQ610RF THERMOSTAT Quick Guide
SALUS WQ610RF Wireless Slim Programmable Thermostat technical Specification Guide
SALUS WQ610RF 230V Wireless Slim Programmable Thermostat technical Specification Guide
Leave a Reply