klima C16 WiFi ELECTRIC THERMOSTAT Instruction Manual

klima C16 WiFi ELECTRIC THERMOSTAT

Explanation of symbols

Start-up Wizard

Clock

  • When the thermostat is connected to the Wi-Fi thermostat it will automatically update the day, hour and minutes.

Sensor Selection

  • 00 => Floor Sensor: run by floor sensor(default)
  • 01 => Room-in Sensor: run by built-in room sensor (built into thermostat)
  • 02 => Room-in sensor and floor sensor: run by built-in sensor with floor temp limit.
  • 03 => Room-out sensor: Run by external room sensor
  • 04 => Room-out sensor and floor sensor: Run by external room sensor with floor temp limit

Floor temperature limit

(This only happens if Both sensors are chosen e.g. Room sensor and floor sensor)

  • Select a temperature limit as this is needed to protect the floor.

Thermostat location

  • Either select it for home use or office use so it will follow default factory set office or home hours and can be changed.

Program

Temporary Override Temperature

Mode

  • To select a mode, press the .

Key-Lock

  • This allows the thermostat buttons to be locked and no buttons to be pressed. To lock the thermostat press and hold and for 3 seconds to lock the thermostat to unlock the thermostat repeat the same process.

Menu

  • On the main of the thermostat press and hold the for 3 seconds to enter menu.

SET

END

Clock

The default interface of the menu is CLK(Clock). The day and time are set in this setting.

  • Press the to enter the setting to set the day
  • Press the or to change the day
  • Press the to enter the hour setting
  • Press the or to change the hour
  • Press the to enter the minute setting
  • Press the or to set the minutes
  • Press the to go back to the main page

Event setting

Default parameters

To change the parameter and set Events. In Automatic mode, the thermostat will run according to the times set. On the clock interface, press the or to select ‘EVE’.

  • Press the to allow a day to be selected
  • Press or to select a day or to end the selection
  • Press the to enter the timing for that day, or to go back to the main page
  • Press or to select event
  • Press to select the program start time
  • Press or to set the hour for the program starting time
  • Press to enter the minute’s
  • Press or to set the minute for the program starting time
  • Press to enter the temperature setting
  • Press or to select a temperature
  • Press to go back the Event menu setting, or to go back to day selection if it’s on the last event

Readout

  • Work out the time of which the thermostat is on for as a percentage, E.G. the underfloor heating is on 1 day out of 7 days
  • On the main page press the or to select READ
  • Press to enter readout menu, the interface will show the heating timings from the previous day
  • Press or to choose 1 day, 30 days (1 month), 365 days (1 year) it will show when the heating is on within certain times.

Advanced Setting

  • On the interface press the or to select ‘SET’
  • Press for advanced settings
  • Press go through the list of settings
  • Each setting can then be changed by pressing or
  • View next to help identify what page you require to change your thermostat accordingly

  1. Sensor Selection:
    • There are 5 options:
      • 00 => Floor sensor (default setting)
      • 01 => Room-in Sensor (Ran by built-in air sensor)
      • 02 => Room-in Sensor and Floor Sensor (Ran by built-in air sensor with floor temp limit)
      • 03 => Room-out Sensor (Ran by an external room sensor)
      • 04 => Room-out Sensor and Floor Sensor (Ran by external room sensor with floor temp limit)
  2. Room temp calibration is done by a room sensor
  3. Floor temp calibration is done by a floor sensor
  4. Floor temp limit did when using both room and floor sensor
  5. Select to set every day individually or set the weekdays and weekends individually
  6. Used for heating or cooling
  7. Adaptive function learns over time when it is the best time to come on and heat the floor to reach the required temperature at the next period.
  8. A thermostat located in an office or home
  9. Reset thermostat to factory defaults

Open Window Detection

  • This function only works when the Room sensor OR floor and room sensor are selected. The thermostat will shut off for 15 minutes when the windows are open. As it will detect the room temperature decreasing.

Troubleshooting

  • E1: Room-in Sensor Error
  • E2: Floor Sensor Error
  • E4: Room-out Sensor Error

Reference

Download Manual:

klima C16 WiFi ELECTRIC THERMOSTAT Instruction Manual

Other Manual:

klima C16 WiFi ELECTRIC THERMOSTAT User Manual

klima C16 WiFi ELECTRIC THERMOSTAT Instruction Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago