Thermogroup

Thermogroup 9.2mG Programmable Thermostat User Guide

Thermogroup 9.2mG Programmable Thermostat

Compatibility

Thermotouch Manual Glass is compatible with Thermogroup NTC 10K floor sensor probes. NTC 10kΩ @ 25°C If your existing floor probe is from another thermostat manufacturer and is not compatible, set your
thermostat to ambient temperature sensing mode. (Not advisable for timber or other temperature-sensitive floors).

Replacing an existing thermostat?
Contact the manufacturer’s technical department and ask for the rating of the floor sensor at 25°C.

What’s in the box?

Check you’ve got everything:

  • manual thermostat (5215 or 5216)
  • Floor sensor probe (3m)
  • Floor sensor conduit (2m)
  • Fixing screws
  • Installation guide

You will also need:

  • Electrical screwdriver
  • Deep electrical back box
  • Electrical test meter

Before you start
Your thermostat should be:

  • Installed 1.2 – 1.5m from the floor
  • On an interior wall
  • Outside any wet zones (IP30)
  • Installed on an RCD-protected circuit
  • Away from drafts or heat influences
  • Installed so that the floor sensor probe can be laid in a heated area of the floor
  • Installed by a professional, in line with current IEE 17th Edition Part P regulations and local standards

Installing your thermostat

Switch off mains power
You will be installing your thermostat as part of a high-voltage mains electrical circuit. To ensure your safety and protect the thermostat, switch off the main power and remove the fuse from the spur before you start the installation.

CAUTION High Voltage Cables

Installation location
At this stage, it is likely that an RCD-protected electric underfloor heating system has been installed and a back box is already in place. The underfloor heating cold tail should be pulled up through the back box, and the sensor probe installed (in the conduit provided) within the wall cavity or pre-chased channel in a solid wall.

Maximum distances
Your thermostat can be installed up to 50m away from the underfloor heating system it is controlling, provided that the floor sensor is used to control the temperature. Underfloor heating cold tails and floor sensor probes can be extended up to 50m. Connect multiple heaters to the thermostat in parallel.

Release mounting plate


Use a flat screwdriver to press in the catch (1) and push the fascia down as shown (2) to release the clips holding the back plate and the thermostat fascia together. Disconnect the white ribbon cable.

Wiring diagram


Connect the Thermostat to the underfloor heating (UFH) cold tail, power supply, and floor temperature sensor. The floor temperature sensor is not polarity sensitive.

Fix mounting plate in position


Use a cross-head screwdriver to fix the mounting plate to the back box in the wall. Now you can connect the white ribbon cable to the fascia.

Fix thermostat fascia in place


Locate the thermostat onto the mounting plate and push it down to clip in place.

Switching on your system
It is important that all adhesives and grouting is dry and fully cured before you switch on your underfloor heating. Most adhesives take between 7 to 10 days to cure. Follow manufacturer guidelines. The temperature of your underfloor heating should be increased gradually to avoid thermal shock on the floor. Start at 15°C and work up to your desired temperature of 2-3°C per day. Observe any maximum temperature guidelines from your floor manufacturer.

Advanced Settings

Adjusting the settings
To access the settings, switch the unit off by pressing it.
Press and hold together for 7 seconds. Press to cycle between settings 01 to 12. Use and adjust the settings.
When you are finished, leave the thermostat idle for 30 seconds. It will automatically save your settings and switch them off.
Switch the unit on by pressing to continue using the thermostat with your new settings.

MENU DESCRIPTION RANGE DEFAULT
01 Temperature calibration -8°C ~ 8°C 0°C
02 Maximum set point 5°C ~ 80°C 35°C
03 Minimum set point 5°C ~ 80°C 5°C
04 Sensor mode IN (Ambient), OUT (Floor), ALL (Ambient with floor limit) OUT
05 Frost protection 5°C ~ 15°C or – (Off) 5°C
06 Floor temperature display (ALL sensor mode only)
07 Temperature limit 10°C ~ 80°C (ALL mode only) 35°C
08 Status after power failure LA: On as before, OF: Off after power failure LA
09 Software version 5215: 7021 V1.1

5216: 5101 V1.1

10 Factory reset rE (yes)
11 Backlight timer 10 secs – 300 secs (5 mins) 20s
12 Backlight brightness level 1 (min), 2, 3, 4 (max) 4

User interface

  1. Measured temperature
  2. Heating on icon
  3. Lock the icon
  4. Up arrow
  5. Power button
  6. Down arrow
  7. Set the temperature

Technical data

Supply voltage 230V 50/60Hz
Maximum load 16A
Backup storage EEPROM
Temperature range 5 ~ 80°C (0.5°C increments)
Accuracy ±0.5°C
Sensor rating NTC 10kΩ @ 25°C
Consumption 2W
Warranty 3 years
IP rating IP30
Width 85mm
Height 85mm
Depth 46mm (31mm in wall)

Key lock

Locking the keys
To lock the keys press and hold and together for 7 seconds. The icon will appear when the keys are locked and the keys will not function. To unlock the keys press and hold and together for 7 seconds.

Factory reset
Find menu item 10 in the advanced settings (page 15). Press and then. The thermostat will reset to factory settings after 7 seconds. This will totally erase the time, date, heating program, and any adjusted settings.

Service and support

Thermogroup UK
Bridge House
Hop Pocket Lane Paddock Wood
Kent TN12 6DQ UNITED KINGDOM
0800 019 5899
01622 689 440
www.thermogroupuk.com
sales@thermogroupuk.com

Thermogroup EU Pinnacle House Newtown Cross
The Ward. Dublin 11 D11 K27C
Rep. of IRELAND
01 866 0584
www.thermogroupeu.com
sales@thermogroupeu.com

Thermogroup AU Thermogroup Pty Ltd
PO Box 822
Leeton NSW 2705 AUSTRALIA
1300 368 631
www.thermogroup.com.au
sales@thermogroup.com.au

Watch the video guide on our website:www.thermogroupuk.com
www.thermogroup.com.au

REFERENCE:

DOWNLOAD MANULAS:

Thermogroup 9.2mG Programmable Thermostat User Guide

OTHER MANUALS:

Thermogroup 9.2mG Thermostat Product Specication Guide

Thermogroup 9.2mG Programmable Thermostat User Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago