Thermotouch Manual Glass is compatible with Thermogroup NTC 10K floor sensor probes. NTC 10kΩ @ 25°C If your existing floor probe is from another thermostat manufacturer and is not compatible, set your
thermostat to ambient temperature sensing mode. (Not advisable for timber or other temperature-sensitive floors).
Replacing an existing thermostat?
Contact the manufacturer’s technical department and ask for the rating of the floor sensor at 25°C.
Check you’ve got everything:
You will also need:
Before you start
Your thermostat should be:
Switch off mains power
You will be installing your thermostat as part of a high-voltage mains electrical circuit. To ensure your safety and protect the thermostat, switch off the main power and remove the fuse from the spur before you start the installation.
CAUTION High Voltage Cables
Installation location
At this stage, it is likely that an RCD-protected electric underfloor heating system has been installed and a back box is already in place. The underfloor heating cold tail should be pulled up through the back box, and the sensor probe installed (in the conduit provided) within the wall cavity or pre-chased channel in a solid wall.
Maximum distances
Your thermostat can be installed up to 50m away from the underfloor heating system it is controlling, provided that the floor sensor is used to control the temperature. Underfloor heating cold tails and floor sensor probes can be extended up to 50m. Connect multiple heaters to the thermostat in parallel.
Release mounting plate
Use a flat screwdriver to press in the catch (1) and push the fascia down as shown (2) to release the clips holding the back plate and the thermostat fascia together. Disconnect the white ribbon cable.
Wiring diagram
Connect the Thermostat to the underfloor heating (UFH) cold tail, power supply, and floor temperature sensor. The floor temperature sensor is not polarity sensitive.
Fix mounting plate in position
Use a cross-head screwdriver to fix the mounting plate to the back box in the wall. Now you can connect the white ribbon cable to the fascia.
Fix thermostat fascia in place
Locate the thermostat onto the mounting plate and push it down to clip in place.
Switching on your system
It is important that all adhesives and grouting is dry and fully cured before you switch on your underfloor heating. Most adhesives take between 7 to 10 days to cure. Follow manufacturer guidelines. The temperature of your underfloor heating should be increased gradually to avoid thermal shock on the floor. Start at 15°C and work up to your desired temperature of 2-3°C per day. Observe any maximum temperature guidelines from your floor manufacturer.
Adjusting the settings
To access the settings, switch the unit off by pressing it
Press
When you are finished, leave the thermostat idle for 30 seconds. It will automatically save your settings and switch them off.
Switch the unit on by pressing
MENU | DESCRIPTION | RANGE | DEFAULT |
01 | Temperature calibration | -8°C ~ 8°C | 0°C |
02 | Maximum set point | 5°C ~ 80°C | 35°C |
03 | Minimum set point | 5°C ~ 80°C | 5°C |
04 | Sensor mode | IN (Ambient), OUT (Floor), ALL (Ambient with floor limit) | OUT |
05 | Frost protection | 5°C ~ 15°C or – (Off) | 5°C |
06 | Floor temperature display | (ALL sensor mode only) | |
07 | Temperature limit | 10°C ~ 80°C (ALL mode only) | 35°C |
08 | Status after power failure | LA: On as before, OF: Off after power failure | LA |
09 | Software version | 5215: 7021 V1.1 5216: 5101 V1.1 | |
10 | Factory reset | rE (yes) | |
11 | Backlight timer | 10 secs – 300 secs (5 mins) | 20s |
12 | Backlight brightness level | 1 (min), 2, 3, 4 (max) | 4 |
Supply voltage | 230V 50/60Hz |
Maximum load | 16A |
Backup storage | EEPROM |
Temperature range | 5 ~ 80°C (0.5°C increments) |
Accuracy | ±0.5°C |
Sensor rating | NTC 10kΩ @ 25°C |
Consumption | 2W |
Warranty | 3 years |
IP rating | IP30 |
Width | 85mm |
Height | 85mm |
Depth | 46mm (31mm in wall) |
Locking the keys
To lock the keys press and hold
Factory reset
Find menu item 10 in the advanced settings (page 15). Press
Thermogroup UK
Bridge House
Hop Pocket Lane Paddock Wood
Kent TN12 6DQ UNITED KINGDOM
0800 019 5899
01622 689 440
www.thermogroupuk.com
sales@thermogroupuk.com
Thermogroup EU Pinnacle House Newtown Cross
The Ward. Dublin 11 D11 K27C
Rep. of IRELAND
01 866 0584
www.thermogroupeu.com
sales@thermogroupeu.com
Thermogroup AU Thermogroup Pty Ltd
PO Box 822
Leeton NSW 2705 AUSTRALIA
1300 368 631
www.thermogroup.com.au
sales@thermogroup.com.au
Watch the video guide on our website:www.thermogroupuk.com
www.thermogroup.com.au
DOWNLOAD MANULAS:
Thermogroup 9.2mG Programmable Thermostat User Guide
OTHER MANUALS:
Thermogroup 9.2mG Thermostat Product Specication Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…