Terminal | Description |
L,N | Power Supply 230 V AC |
NSB | Night SetBack (input 230 V AC) |
SL | Switched output (230 V AC) |
S1, S2 | External temperature sensor |
The VS35 thermostat has been designed for flush mounting in a standard electrical box with a diameter of 60 mm.
An additional temperatur Te sensor
VS35 thermostat in connection with wiring centre
In this diagram, the VS30 thermostat manages the NSB function, more details about NSB function can be found on the next page.
Note: In the KL06 wiring centre, the SL terminal is marked with an arrow icon .
NSB function and an additional temperature sensor
VS35 thermostat in connection with actuator or pump
VS30 thermostat in connection with a boiler with a “NO” voltage free terminal through the RM-16A relay
Press any button to highlight the screen, then follow the steps below:
temperature settings
There are 4 temperature levels available. In manual mode only one temperature level is active (icon in the frame
Press any button to highlight the screen, then follow the steps below:
NSB function – automatic mode
The NSB (Night SetBack) function can automatically change temperatures on VS35 daily thermostats via VS30 programmable thermostat connected to a wiring centre (or another external clock). NSB function switches between comfortable temperature
To activate the automatic mode, select the icon A. On display together with the A icon, the controller indicates active temperature mode:
Press any button to highlight the screen, then follow the steps below:
Note: For the NSB function to work, it is necessary to connect the wirings properly. Connection diagrams can be found on the previous page.
Press any button to highlight the screen, then follow the steps below:
Note: Heating / cooling mode can also be set using the service parameter d18.
The VS35 thermostat allows you to adjust the displayed temperature ± 3.0°C. You can do it according to the following steps:
Press any button to highlight the screen, then follow the steps below:
Note: You can also set the Offset temperature value using the service parameter d02.
Press any button to highlight the screen, then follow the steps below:
Note: To restore the thermostat’s factory settings, in step 2 set the PSuu to 47 code, and confirm the selection with the button.
dxx | Function | Value | Description | Default value |
d01 | Control method temperature | 0 | PWM algorithm | 0 |
1 | Span ±0.25°C | |||
2 | Span ±0.5°C | |||
d02 | Offset temperature | from -3.0°C to +3.0°C | If the thermostat indica- tes wrong temperature, you can correct it by ± 3.0°C | 0°C |
d03 | Using a floor temperature sensor (S1, S2) | 0 | No sensor | 0 |
1 | Sensor is connected | |||
d04 | External sensor used for air or floor temperature measurement (Function is active, when d03=1) | 0 | Thermostat measures the temperature only on the external sensor |
0 |
1 | The sensor is used as a protection against overheating the floor | |||
d05 | Cooling mode control method | 1 | Span ±0.5°C | 2 |
2 | Span ±1.0°C | |||
d06 | Type of thermoelectric actuator | 0 | NO – normally open | 1 |
1 | NC – normally closed | |||
d07 | Valve protection | 0 | OFF | 1 |
1 | ON | |||
d08 | Frost protection temperature | 5-17°C | Frost protection / Holiday mode temperature | 5°C |
d12 | Heating temperature limit | 5-35°C | The maximum heating temperature that can be set by the user | 35°C |
d13 | Cooling temperature limit | 5-40°C | The minimum cooling temperature that can be set by the user | 5°C |
d14 | Maximum floor temperature (this function is active in heating mode when d04 = 1) |
6-45°C | In order to protect the floor from overheating, heating will be turned OFF, when the maximum temperature of the floor sensor will be reached |
27°C |
d15 | Minimum floor temperature (this function is active in heating mode when d04 = 1) |
6-45°C | In order to protect the floor, heating will be turned ON, when the minimum temperature of the floor sensor will be reached |
10°C |
d16 | Lower floor temperature limit for cooling (this function is active when d04 = 1) |
6-45°C | In order to protect the floor, cooling will be turned OFF, when the minimum temperatu- re will be reached |
6°C |
d18 | Operating mode HEATING / COOLING | 0 | Heating system | 0 |
1 | Cooling system |
Error code | Description |
Err02 | The maximum/minimum floor temperature has been exceeded |
Err03 | The temperature sensor is faulty |
Err04 | The temperature sensor is shorted |
Download Manual
SALUS VS35 Wired Digital Non-Programmable Thermostat Quick Guide
OTHER MANUALS
SALUS VS35 Wired digital Non-Programmable Thermostat User Manual
SALUS VS35 Wired digital Non-Programmable thermostat Wiring Daigram
SALUS VS35 Wired digital Non-Programmable thermostat Quick Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…