Pro1 Technologies, Inc.
Springfield, MO 65804
Toll-Free: 888-776-1427 Web: www.pro 1 iaq.com
Hours of Operation: M-F 9 AM – 6 PM Eastern
Description | |
Gas or Oil Heat | No |
Electric Furnace | No |
Heat Pump {No Aux. or Emergency Heat) | Yes |
Heat Pump {with Aux. or Emergency Heat) | Yes |
Multi-stage Systems | No |
Heat Only Systems | No |
Heat Only Systems – Floor or Wall Furnaces | No |
Cool Only Systems | No |
Millivolt | No |
Power Type
A trained, experienced technician must install this product
Carefully read these instructions. You could damage this product or cause a hazardous condition if you fail to follow these instructions.
Wall locations
The thermostat should be installed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulation.
Installation Tip
Pick an installation location that is easy for the user to access. The temperature of the location should be representative of the building.
Getting to know your thermostat
Important
The low battery indicator is displayed when the AA battery power is low. If the user fails to replace the battery within 21 days, the screen
will only show the low battery indicator but maintain all functionality. If the user fails t replace the batteries after an additional 21 days (days 22-42 since the first “low battery” display) the set points will change to SS°F(Heating) and 8S°F(Cooling). If the user adjusts these setpoints away from these it will hold for 4 hours and then return to either SS°F or 8S0 F. After day 42 the batteries must be replaced immediately to avoid freezing or overheating because the thermostat will shut the unit off until the battery is changed.
Removing the private label badge
Gently slide a screwdriver into the bottom edge of the badge. Gently turn the screwdriver counter clockwise. The badge is held on by a
magnet in the well of the battery door. The badge should pry off easily. Magnet indoor t Does not use force.
About This Badge
All of Our thermostats use the same universal magnetic badge. Visit the company website to learn more about our free private label program.
Caution: A Electrical Hazard Failure to disconnect the power before beginning to install this product can cause electrical shock or equipment damage.
Mercury Notice: All of Our products are mercury-free. However, if the product you are replacing contains mercury, dispose of it properly. Your local waste management authority can give Your instructions on recycling and proper disposal.
For vertical mount put one screw on top and one screw on bottom For horizontal mount put one screw left and one screw right.
New Thermostat Installation Wiring
Typical 2H/1 C heat pump system
Typical 2H/1 C heat pump system with separate emergency heat
NOTE: In many systems with no emergency heat relay a jumper can be installed between E and W2.
Caution: Electrical Hazard Failure to disconnect the power before beginning to install this product can cause electrical shock or equipment damage.
Warning:
All components of the control system and the thermostat installation must conform to Class II circuits per the NEC Code.
Wiring
Brand
Prol | 24V Common
( (optional) | 24V Hot
R | Changeover in Cooling 0 | Changeover in Heating
B | Fan
G | Emergency Heat E | Compressor
y | Auxiliary Heat
W2 | Malfunction Light
None, Tape Off |
Arco/Snrder | C | R | 0 | G | E | y | Wl | X | |
B.D.P. | C | R | 0 | G | E | y | Wl | F | |
Carrier | C | R | 0 | G | E | y | W2 | L | |
Coleman | BLCK | RED | V | G | y | W2 | |||
G.E. B | R | 0 | G | X2 | y | w | |||
Heil-Quaker | B | R | 0 | G | y | W2 | |||
Honeywell | C | R | 0 | B | G | E | y | Aux | L |
Janitrol | C | R | 0 | G | E | y | W2 | ||
Lennox | X | VNR | R | F | E | M | y | L | |
Magic Chef | C | R | 0 | G | E | y | w | ||
Rheem | X | R | B | G | E | y | W2 | L | |
Ruud | X | R | B | G | E | y | W2 | L | |
Trane | B | R | 0 | G | X2 | y | w | F | |
Weatherking | C | R | Yl | G | Wl | E | |||
Wesco | C | R | Yl | G | E | Wl | W2 | ||
Westinghouse | X | R/V | 0 | z | G/F | E | Y/C | W/H2 | |
White-Rodgers | C | R | 0 | B | G | E | y | W2 | L |
York | B | R | 0 | G | y | w |
Note: This cross-reference represents typical systems and is not necessarily representative of your particular
application. Always consult the original equipment manufacturer for proper installation instructions.
Terminal Designations
Note:
In many systems with no emergency heat relay a jumper can be installed between E and W2.
Fahrenheit/Celsius Display
Select F or C with the jumper pin on the back of the thermostat. F is for Fahrenheit and C for Celsius
12 or 24 Hour Time
12 or 24 hours (military time) can be selected with the jumper pin.
Important
The RESET button must be pressed after changing any switch or jumper pin setting. Batteries must be installed for this operation
This thermostat has a technician setup menu for easy installer configuration. To setup the thermostat for your particular application:
Use their keys to change settings and the NEXT STEP or PREV STEP key to move from one step to another.
Note: Only press the DONE key when you want to exit the Technician Setup options.
Swing Setting Tip
The second stage will turn on at 2x the swing set. The second stage will turn off when 1 x the swing is reached. For example, if the swing set is .8 degrees for heating and the thermostat is set at 70°F, the first stage will turn on at approximately 69.2°F. The second stage will turn on at 68.4°F. The second stage will turn off at 69.2°F and the first will turn off at 70.8°F.
Set Time
Follow the steps below to set the day of the week and current time:
Note
Our Standard staging logic, optional satisfy setpoint, and optional staging deal allow for job-by-job customization that balances comfort, energy efficiency, and equipment longevity.
Mount Thermostat
Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat, then push gently until the thermostat snaps in place.
Battery Installation
Battery installation is recommended even if the thermostat is hardwired (C terminal connected). When the thermostat is hardwired and batteries are installed, the thermostat will activate a compressor delay of 5 minutes when the thermostat detects a power outage from the hardwired power supply.
Important
High-quality alkaline batteries are recommended. Rechargeable batteries or low-quality batteries do not guarantee a 1-year life span.
Filter Change Reminder
If your installing contractor has configured the thermostat to remind you when the air filter needs to be changed, you will see FILT in the
display when your air filter needs to be changed. FILT will be shown in the display after your system has run long enough to require an air
filter change. Resetting the filter change reminder: When the FILT reminder is displayed, you should change your air filter and reset the reminder by holding down the second button from the top left side of the thermostat for 3 seconds.
Understanding Thermostat Staging
Your thermostat will control two stages of heating. The thermostat will try to maintain your comfort setting using the first stage for energy efficiency. The second stage of heating will only be used if your thermostat cannot maintain your comfort setting using only one stage. When the second stage is used you will see +1 in the display.
Downlaod Manual: Pro1 Technologie T721i Thermostat Installation Manual
https://device.report/energystar/2396768
Pro1 Technologie T721i Thermostat – Energy Star Certification
Other Manual: Pro1 Technologie T721i Thermostat Operation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…