Nuheat

Nuheat Home Touchscreen Programmable Thermostat Data Sheet Guide

Nuheat Home Touchscreen Programmable Thermostat Data Sheet

HOME SCREEN

ITEMS

  1. Change date and time
  2. Current temperature
  3. Target temperature or setpoint
  4. Heating indicator – when visible, system is heating.
  5. Access energy use data
  6. Access Main Menu
  7. GFCI test Button
  8. GFCI Indicator
  9. On/Off Button
    Press to turn the system ON/Reset GFCI
    Hold to turn the system OFF

TECHNICAL DATA

  • Supply …..120/240 Vac 50/60 Hz
  • Load …….max. 15 A (resistive load)
  • Power …..1800 W at 120 Vac
  • ……3120 W at 208 Vac
  • ……3600 W at 240 Vac
  • GFCI ……Class A (5 mA trip level)
  • Temperature range …..+5 to +40°C, +41 to +104°F
  • Amb. temp. range …..0 to +25°C, +32 to +77°F
  • Construction of Control: Electronic room thermostat for regulating electrical underfloor heating.
  • Method of Mounting Control: Independently mounted control for flush mounting
  • Type of Action:…..Type 2.B.
  • Rated Impulse Voltage:….2500 V
  • Control Pollution Degree: …..PD2

WARNINGS:
To avoid electric shock, disconnect the heating system power supply at the main panel before installation and maintenance of the thermostat. Keep thermostat air vents clean and free from obstruction. This thermostat is an electrical product and must be installed in compliance with the National and/or Local Electrical Code. Installation must be performed by qualified personnel where required by law.

QUICK START GUIDE

SETUP AND TROUBLESHOOTING VIDEOS, as well as a complete operating manual, is available on nVent.com/NUHEAT.

Loosen screw at the bottom and remove the faceplate.
Do not attempt to remove the screw completely.

Turn the power source OFF at the breaker panel. Make electrical connections
on the power base. DO NOT over-tighten the terminal screws. Secure protective cap onto the power base.

The floor sensor cable must be routed to the junction box separate from power wires and the heating cable cold lead. Ensure that the insulation on the electrical wiring and the floor sensor inside the junction box are not damaged.
Thread floor sensor through a hole in the power base. Push electrical wires to the back of the electrical box.

Push power base into the electrical box. Secure power base to wall.

Make sensor connections.
* Refer to instructions included with expansion unit.

Remount faceplate. Do not touch the screen when mounting the faceplate onto the power base. Turn the power source ON at the breaker panel

Perform system tests. Once systems tests are complete, press “Start Using Thermostat” and complete the setup wizard.

Reference

Nuheat Home Touchscreen Programmable Thermostat Data Sheet Guide

other manuals

Nuheat Home Touchscreen Programmable Thermostat Operating Manual

Nuheat Home Touchscreen Programmable Thermostat Data Sheet Guide

Nuheat Home Touchscreen Programmable Thermostat 120V Relay Wiring Guide

Nuheat Home Touchscreen Programmable Thermostat 240V Relay Wiring Guide

Nuheat Home Touchscreen Programmable Thermostat 240V Relay General Wiring Guide

Nuheat Home Touchscreen Programmable Thermostat Data Sheet Guide

wpx_thermostats

Recent Posts

Bad Ragaz Casino No Deposit Bonus Codes For Free Spins 2026

Bad Ragaz Casino No Deposit Bonus Codes For Free Spins 2026 Details pertaining to the…

2 weeks ago

Online Slot Games For Money

Online Slot Games For Money Playing online casinos UK on a mobile device Spin the…

2 weeks ago

Prime Fortune Casino No Deposit Bonus Codes For Free Spins 2026

Prime Fortune Casino No Deposit Bonus Codes For Free Spins 2026 Fantasy sports became a…

2 weeks ago

Online Casino Real Money Uk No Deposit

Online Casino Real Money Uk No Deposit Get ready to play the most realistic card…

2 weeks ago

Sin88 Casino No Deposit Bonus Codes For Free Spins 2026

Sin88 Casino No Deposit Bonus Codes For Free Spins 2026 This can be part of…

2 weeks ago

How To Always Win Blackjack

How To Always Win Blackjack Casino offer terms and conditions in UK Here is how…

2 weeks ago