Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Model | Programming Choices | ||
1F95-0671 | 7 Day | 5/1/1 Day | Non-Programmable |
THERMOSTAT APPLICATION GUIDE
Description | |
Heat Pump (No Aux. or Emergency Heat) | Yes |
Heat Pump (with Aux. or Emergency Heat) | Yes |
Systems with up to 4 Stages Heat, 2 Stages Cool | Yes |
Heat Only Systems | Yes |
Millivolt Heat Only Systems – Floor or Wall Furnaces | Yes |
Cool Only Systems | Yes |
Gas or Oil Heat | Yes |
Electric Furnace | Yes |
Hydronic (Hot Water) Zone Heat – 2 Wires | Yes |
Hydronic (Hot Water) Zone Heat – 3 Wires | Yes |
Wired Remote Temperature Sensor (Indoor or Outdoor) | Yes |
Dual Fuel Feature (Heat Pump Mode, Outdoor Remote Required) | Yes |
Electrical Rating:
CAUTION To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this product may replace a product that contains mercury.
Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury. Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container. For proper disposal of a product containing mercury or a sealed container of spilled mercury, place it in a suitable shipping container. Refer to www.thermostat-recycle.org for location to send product containing mercury.
WARNING Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code.
Remove Old Thermostat
Before removing wires from old thermostat, mark wires for terminal identification so the proper connections will be made to the new thermostat.
Installing New Thermostat
2 “AA” alkaline batteries are included in the thermostat at the factory with a battery tag to prevent power drainage. Remove the battery tag to engage the batteries.
To replace batteries, set system to OFF, remove thermostat from wall and install the batteries in the rear along the top of the thermostat (see Figure 1). For best results, use a premium brand “AA” alkaline battery such as Duracell® or Energizer®. If the home is going to be unoccupied for an extended period (over 3 months) and
Power Stealing Switch
The Power Stealing Switches (Figure 1, rear view) should be left in the “On” position for most systems. The information in the following table details the thermostat power method and switch options.
Thermostat Power Method | Switch Position/Description |
Battery Powered, no 24 Volt system power available. | Switches “On”, thermostat runs on batteries. |
Hardwired with Battery Back-up, for 24 Volt systems with common connection from transformer to “C” terminal on thermostat. | Switches “On”, thermostat runs on power directly from transformer with battery back-up. |
*Battery Powered with Power Stealing Assist, for 24 Volt systems with no common connection from transformer to “C” terminal on thermostat. | Switches “On”, thermostat runs on batteries and supplemental power drawn through the heat or cool circuit. |
Note: Power Stealing Assist is very reliable to increase battery life, but on a small number of heating or cooling systems with high-impedance electronic modules you may observe one of the following conditions:
If the Power Stealing Assist method is not compatible with your system, place the Power Stealing Switches to “Off”. This cancels Power Stealing Assist, operates the thermostat on batteries and corrects the condition.
Refer to equipment manufacturers’ instructions for specific system wiring information. After wiring, see the CONFIGURATION section for proper thermostat configuration. Wiring diagrams shown are for typical systems and describe the thermostat terminal functions.
TERMINAL DESIGNATION DESCRIPTIONS
Refer to equipment manufacturers’ instructions for specific system wiring information. This thermostat is designed to operate a single-transformer or two-transformer system.
You can configure the thermostat for use with the following systems:
Refer to equipment manufacturers’ instructions for specific system wiring information. This thermostat is designed to operate a single-transformer or two-transformer system. You can configure the thermostat for use with the following systems:
Programming and Configuration Items
Thermostat must be in Heat, Cool or Auto. Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press
INSTALLER/CONFIGURATION MENU | ||||||
Menu Ref. | HP | SS | Press Button | Displayed (Factory Default) | Press | Comments |
1 | 1 | 1 | MENU | (MS 2) | HP 1, HP 2, SS 1 | Selects Multi-Stage (MS 2 No Heat Pump), Heat Pump 1 (HP 1, 1 compressor), Heat Pump 2 (HP 2, 2 compressor or 2 speed compressor), or Single Stage (SS 1) |
2 | 2 | 2 | MENU | (GAS) for SS or MS (ELE) for HP | ELE | GAS setting: furnace controls the blower ELE setting: thermostat controls the blower |
3 | 3 | 3 | MENU | CS (3) | 0, 1, 2, 4, 5, 6 | Selects Cool Savings Value 1 (low) to 6 (high), Value 0 disables feature |
4 | 4 | 4 | MENU | E (On) | OFF | Selects Energy Management Recovery (EMR) On or OFF. |
5 | – | 5 | MENU | CR Heat (ME) | SL, FA | Selects Adjustable Anticipation, cycle rate, Heat (This item only appears when MS 2 or SS 1 is selected above) |
6 | 5 | – | MENU | CR Heat Pump (ME) | SL, FA | Selects Adjustable Compressor Anticipation (Heat Pump) This item only appears when HP 1, HP 2 is selected above |
7 | 6 | 6 | MENU | CR Cool (ME) or CR AU (FA) | SL, FA SL | Selects Adjustable Anticipation, cycle rate, cool (when MS 2 or SS 1 is selected above.) or Selects the cycle rate for Auxiliary stage (when HP 1 or HP 2 is selected above) |
8 | 7 | 7 | MENU | CL (OFF) | CL On | Compressor Lockout Time |
9 | 8 | 8 | MENU | Em Heat, Auto Cool Off or Heat, Auto,Cool Off | Heat Cool Off, Heat Off with Fan icon, Heat Off without Fan icon Cool Off, Auto Off | System Mode Configuration with Automatic Changeover capability |
10 | 9 | 9 | MENU | dL (On) | dL OFF | Selects Display Light On or OFF |
11 | 10 | 10 | MENU | 0 (current temperature) | 1 HI, 2 HI, 3HI, 4 HI, 1 LO, 2 LO, 3 LO, 4 LO | Adjustable Ambient Temperature Display |
12 | 11 | 11 | MENU | °F | °C | Selects Fahrenheit/Celsius Temperature Display |
13 | 12 | 12 | MENU | (On) b | OFF | Select Beeper OFF to stop audible key feedback (not applicable on all models) |
14 | 13 | 13 | MENU | P (7) | 3, 0 | Defaults 7-day programming (P7) but non- programmable (0) or 5/1/1 programming (P3) is available on most models. |
15 | 14 | 14 | MENU | PS (4) | 2 | Selects Program periods per day: 4 = Morn, Day, Eve, Night 2 = Day, Night |
16 | 15 | 15 | MENU | Heat AS (On) | OFF | Automatic Schedule for heat mode |
17 | 16 | 16 | MENU | Cool AS (On) | OFF | Automatic Schedule for cool mode |
18 | 17 | – | MENU | Heat FA (On) | OFF | Fast Heat option may be disabled by selecting OFF. NA to SS or HP1 config. |
19 | 18 | – | MENU | Cool FA (On) | OFF | Fast Cool option may be disabled by selecting OFF. NA to SS or HP1 config. |
20 | 19 | 17 | MENU | Remote (OFF) | On | Selects Remote Sensor On/OFF |
MENU | Remote (In) | Outdoor | Selects Remote Sensor to outdoor NA is Remote Sensor OFF | |||
MENU | Indoor Loc (On) | OFF | Selects Local Sensor (in thermostat) to OFF. N/A if Remote is selected to Outdoor |
21 | 20 | 18 | MENU | dS (On) | Off | Selects Automatic Daylight Saving Time option |
22 | 21 | 19 | MENU | (OFF) Keypad Lockout | L, P, Limit | Selects one of 3 Keypad Lockout configurations L – Total Keypad Lockout P – Partial Keypad Lockout (Up and Keys still work) Limit – Limited Temperature Range |
MENU | (000) Keypad Lockout | 1-999 | Selects personal lockout code. 000 is NOT A VALID CODE. | |||
23 | 22 | 20 | MENU | L Heat (99) | L 62 to L 98 | Select Limited HEAT Range Temperature |
24 | 23 | 21 | MENU | L Cool (45) | L 46 to L 82 | Select Limited COOL Range Temperature |
25 | 24 | – | MENU | CO (05) | 06-50 | Selects outdoor Compressor OFF temperature (Balance Point temperature). 05 disables feature. Outdoor Remote required |
MENU | (dF) | EA | Selects between dF (dual Fuel) or EA (Electric Aux) only available if CO is greater than 05 | |||
MENU | Cd (60) | Selects Compressor delay OFF time in seconds (only if dF is selected) | ||||
26 | 25 | – | MENU | AO (80) | Selects AO (Auxiliary OFF) temperature. Fea- ture disabled if 80 is selected. Outdoor Remote required | |
27 | 26 | 22 | MENU | Change Filter (OFF) | On | Selects Filter Change-out Indicator On or OFF. |
MENU | Change Filter (200 h) | 25-1975 h | Change Filter time in 25 hour increments. This menu only appears if On is selected in above. | |||
28 | 27 | 23 | MENU | (OFF) Change UV Lamp | On | Selects UV Lamp Timer: On/OFF |
MENU | (350) Change UV Lamp | 25-1975 | Selects number of Days between changing UV Lamp | |||
29 | 28 | 24 | MENU | Cool On (o) | Heat On (b) | Selects operation of the reversing valve terminal (O/B) output as an O or B terminal |
30 | 29 | 27 | MENU | RUN SCHED | Returns to Normal Operation |
NOTE To prevent static discharge problems, touch side of thermostat to release static build-up before touching any keys.
If at any time during testing your system does not operate properly, contact a qualified service person.
Fan Operation
If your system does not have a G terminal connection, skip to Heating System.
CAUTION Do not allow the compressor to run unless the com-pressor oil heaters have been operational for 6 hours and the system has not been operational for at least 5 minutes.
Heating System
EM bypasses the Heat Pump to use the heat source wired to terminal W/E on the thermostat. EM is typically used when compressor operation is not desired, or you prefer backup heat only.
CAUTION To prevent compressor and/or property damage, if the outdoor temperature is below 50°F, DO NOT operate the cooling system.
Cooling System
Choose the Fan Setting (Auto or On)
Fan Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on.
Fan On selection runs the fan continuously for increased air circulation or to allow additional air cleaning.
Fan Prog On indicates that the fan is programmed to be on for the entire period. The Prog Fan On can be overridden
to have the fan cycle with the system. Press the FAN button to change the fan to Auto. The fan programming will be overridden until the next program period begins or until Run Schedule is pressed.
Set Current Time and Day
Energy Saving Factory Pre-Program
The 1F95-0671 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermostat clock and press the RunSched button. The table below shows the factory set heating and cooling schedule for all days of the week.
* Wake Up (Morn) | Leave For Work (Day) | * Return Home (Eve) | Go To Bed (Night) | |||||
Heating Program | 6:00 AM | 70°F | 8:00 AM | 62°F | 5:00 PM | 70°F | 10:00 PM | 62°F |
Cooling Program | 6:00 AM | 75°F | 8:00 AM | 83°F | 5:00 PM | 75°F | 10:00 PM | 78°F |
Note: You can eliminate these two program periods in the configuration menu (reference #15) if the building is occupied all day. Day period will change to 6:00 AM and 70° and can be programmed as required.
Planning Your Program – Important
The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures.
The 1F95-0671 comes configured for 7 day programming and can also be configured for 5+1+1 programming (see configura-tion section).
Factory settings are listed on Monday, Saturday and Sunday. If you are re-programming a 5+1+1 day schedule, pencil in your own times and temperatures directly below the factory times and temperatures.
If you are re-programming a 7 day schedule, fill in all lines with the times and temperatures you want. Keep the following guidelines in mind when planning your program.
Worksheet for Re-Programming 5+1+1 and 7 Day Program
Heating Program | Wake Up (Morn) | Fan | Leave For Work (Day) | Fan | Return Home (Eve) | Fan | Go To Bed (Night) | Fan | ||||
MON | 6:00 AM | 70°F | Auto | 8:00 AM | 62°F | Auto | 5:00 PM | 70°F | Auto | 10:00 PM | 62°F | Auto |
TUE | ||||||||||||
WED | ||||||||||||
THU | ||||||||||||
FRI | ||||||||||||
SAT | 6:00 AM | 70°F | Auto | 8:00 AM | 62°F | Auto | 5:00 PM | 70°F | Auto | 10:00 PM | 62°F | Auto |
SUN | 6:00 AM | 70°F | Auto | 8:00 AM | 62°F | Auto | 5:00 PM | 70°F | Auto | 10:00 PM | 62°F | Auto |
Cooling Program | Wake Up (Morn) | Fan | Leave For Work (Day) | Fan | Return Home (Eve) | Fan | Go To Bed (Night) | Fan | ||||
MON | 6:00 AM | 75°F | Auto | 8:00 AM | 83°F | Auto | 5:00 PM | 75°F | Auto | 10:00 PM | 78°F | Auto |
TUE | ||||||||||||
WED | ||||||||||||
THU | ||||||||||||
FRI | ||||||||||||
SAT | 6:00 AM | 75°F | Auto | 8:00 AM | 83°F | Auto | 5:00 PM | 75°F | Auto | 10:00 PM | 78°F | Auto |
SUN | 6:00 AM | 75°F | Auto | 8:00 AM | 83°F | Auto | 5:00 PM | 75°F | Auto | 10:00 PM | 78°F | Auto |
The Real Time Clock will adjust automatically for daylight savings time, in the following manner:
Increment one hour at 2 AM on the second Sunday of March and decrement one hour at 2 AM on the first Sunday of November. (New DST effective 2007).
The daylight saving feature can be enabled or disabled in installer configuration menu. Default is DS ON (enabled). After entering installer configuration mode, momentarily press MENU button until the display indicates dS (in actual temperature digits) and on (default – in clock digits).
Programming Tip: Copy Program
When programming your thermostat, you may copy the program from one day to another day or group of days using the Copy key. In 7 day programming mode, a day can be copied to another day or all six other days. In 5/1/1 day programming mode the weekday (Mon – Fri) program can be copied into Sat and Sun or either Sat or Sun.
To copy a program from one day to another:
Enter the Heating Program
Enter the Cooling Program
Automatic Schedule
This feature provides a method to program every day with the most popular time and temperature settings using one key. For this feature to be available, the Auto Schedule options (Installer/Configuration menu item 16, AS Heat, or item 17, AS Cool) must be selected On.
To use Auto Schedule, press RunSched to be sure you are in normal operating mode. In SYSTEM Heat mode, use the keys to select your “Comfort Temperature”. When your “Comfort
Temperature” is selected, press Auto Sched button. The Auto Schedule key will disappear to indicate that the Auto Schedule command has been accepted.
In Heat mode the thermostat will maintain your “Comfort Temperature” during the Morning, Day and Evening periods and setback 6° for the Night. Morning period will begin at 6:30 AM and Night period will begin at 10:30 PM.
To set the Auto Schedule temperature for Cool mode, press SYSTEM to change the mode to Cool and repeat setting the temperature. In Cool mode, the thermostat will maintain your selected “Comfort Temperature” continuously.
The “Comfort Temperature” can be temporarily overridden by changing the setpoint temperature using the
Entering Fan Program
The fan can be programmed to turn on at the beginning of a period and remain on through the whole period. In RunSched mode when the FAN switch indicates Prog Fan On the fan is programmed to be on for the period.
One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 feet). Terminals +, S and – on the terminal block allow connection of the remote sensor. The thermostat must have 24 VAC Common connection to terminal C for the remote sensor to operate. The remote sen-sor can be enabled or disabled in the Installer/Configuration menu, item 20.
When remote sensor, Remote, is selected Off (factory de-fault), no remote sensor is enabled. When remote sensor is selected On, the next step is to select the remote as indoor, Remote In, or outdoor, Remote Outdoor. If the remote is se-lected as Remote In, an additional step will be to select if the temperature shown on the display will be from the thermostat, Loc On, or the remote sensor Loc Off.
In normal operation, when a remote sensor is enabled the time digits of the display will alternate between the time and the remote temperature for three seconds each. Above the remote temperature will be “Remote”, for indoor sensor or “Outdoor Remote”, for outdoor sensor. If the remote sensor is an indoor sensor and the local display has been disabled, the temperature displayed as the room temperature will be the remote sensor temperature.
Sensing Range:
Weighing of Remote Reading:
The thermostat will weight or average the temperature of the indoor remote sensor with the local sensor in the thermostat for each program period. The averaging will be active only when the local sensor and the indoor remote sensor are both functional and enabled in the Installer/Configuration menu.
When the thermostat is in the Set Schedule mode, the weight of the indoor sensor will be shown in the current temperature digits of the display. The weight will show as A2 (average and default), H4 (high) or L1 (low). Pressing the
Example: Local sensor temperature is 80° and the remote sensor is 70°.
The example shows that the weight selected would prioritize the overall averaged temperature between the two sensors. The high weight selection caused the remote sensor to have a higher influence in the calculated temperature average than the local sensor and the low weight selection caused the remote sensor to have less influence.
Dual Fuel Temperature Setpoint
When the thermostat is configured for Heat Pump mode and an outside remote sensor is installed and enabled, the thermostat can monitor the outside temperature to determine when to switch to auxiliary heat and shut down the compressor. This eliminates the need for a fossil fuel kit.
The Compressor Off temperature (CO) set in the configuration menu, item 25, will determine when the auxiliary heat will start and the compressor will shut off. The default setting is 05°F. -15°C (feature disabled) and can be set for 06 to 50°. When the outside temperature falls to the selected temperature, the auxiliary heat system will begin.
The auxiliary heat system can be fossil fuel (dF) or electric heat (EA). This is selected after CO is set greater than 05°. If the auxiliary heat is fossil fuel, (df), a delay time for the compressor shut down (Cd) can be selected. The default for this delay is 60 seconds but can be set from 0 to 99 seconds. If EA is selected, there is no selection for Cd because the compressor will shut down immediately.
Reset Operation
Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings.
If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.
Note: Be sure to review the installer configuration menu settings.
To reset the programming, clock and configuration settings, press the
Symptom | Possible Cause | Corrective Action |
No Heat/No Cool/No Fan (common problems) | 1. Blown fuse or tripped circuit breaker. 2. Furnace power switch to OFF. 3. Furnace blower compartment door or panel loose or not properly installed. 4. Loose connection to thermostat or system. | Replace fuse or reset breaker. Turn switch to ON. Replace door panel in proper position to engage safety interlock or door switch. Tighten connections. |
No Heat | 1. Pilot light not lit. 2. Furnace Lock-Out Condition. Heat may also be intermittent.
3. Heating system requires service or thermostat requires replacement. | Re-light pilot. Many furnaces have safety devices that shut down when a lock-out condition occurs. If the heat works intermittently contact the furnace manufacturer or local HVAC service person for assistance. Diagnostic: Set SYSTEM Switch to HEAT and raise the setpoint above room temperature. Within a few seconds the thermostat should make a soft click sound. This sound usually indicates the thermostat is operating properly. If the thermostat does not click, try the reset operation listed above. If the thermostat does not click after being reset contact your heating and cooling service person or place of purchase for a replacement. If the thermostat clicks, contact the furnace manufacturer or a HVAC service person to verify the heating is operating correctly. |
No Cool | 1. Cooling system requires service or thermostat requires replacement. | Same as diagnostic for No Heat condition except set the thermostat to COOL and lower the setpoint below the room temperature. There may be up to a five minute delay before the thermostat clicks in Cooling. |
Heat, Cool or Fan Runs Constantly | 1. Possible short in wiring. 2. Possible short in thermostat. 3. Possible short in heat/cool/fan system. 4. FAN Switch set to Fan ON. | Check each wire connection to verify they are not shorted or touching together. No bare wire should stick out from under terminal block. Try resetting the thermostat as de- scribed above. If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat/Cool system for correct operation. If the system operates correctly, replace the thermostat. |
Thermostat Setting & Thermostat Thermometer Disagree | 1. Thermostat thermometer setting requires adjustment. | The thermometer can be adjusted +/- 4 degrees. See Temperature Display Adjustment in the Configuration Menu section. |
Furnace (Air Conditioner) Cycles Too Fast or Too Slow (narrow or wide temperature swing) | 1. The location of the thermostat and/or the size of the Heating System may be influencing the cycle rate. | Digital thermostats provide precise control and cycle faster than older mechanical models. The system turns on and off more frequently but runs for a shorter time so there is no increase in energy use. If you would like an increased cycle time, choose SL for slow cycle in the Configuration menu, step 7 (heat) or 8 (cool). If an ac- ceptable cycle rate is not achieved, contact a local HVAC service person for additional suggestions. |
Forgot Keypad Lockout Code | Press the menu button (button will disappear) and hold in for 20 seconds. This unlocks the thermostat. |
White-Rodgers is a business of Emerson Electric Co.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
HELP LINE: 1-800-284-2925
www.white-rodgers.com
www.emersonclimate.com
EMERSON White-Rodgers 1F95-0671 Non-Programmable specification sheet
Download Manuals
EMERSON White-Rodgers 1F95-0671 Non-Programmable Installation and Operating Instructions
EMERSON White-Rodgers 1F95-0671 Non-Programmable Installation and Operating Instructions
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…