EMERSON White-Rodgers 1F95-0671 Non-Programmable Thermostat
Emerson…Broadens the Blue Spectrum of Comfort and Innovation
The Blue™ 6″ Universal Thermostat is designed to deliver a higher level of comfort to your customers. It features the largest display on a keypad-operated thermostat, as well as simple and logical installer setup and programming, enhanced by audio confirmation of entries. Features like variable keypad security to prevent tampering, and temporary and vacation overrides, add convenience. The thermostat offers power stealing assistancefor maximum battery life, and remote sensing, as well as the exclusive Cool Savings™ feature providing the ultimate in comfort control and energy savings. Our +/- 1° Temperature accuracy will keep your customers comfortable and protect their HVAC systems. All Emerson Blue Thermostats are the result of smart, innovative thinking. And you can install Emerson Blue from White-Rodgers with confidence because it’s exclusively for the professional trade. See back for all the specifications.
Features
Exclusive Blue 6″ Features
- Large, 6-square-inch Blue™ display with easy-to-see characters
- Quick one-button programming (See Automatic Schedule section in installation instructions)
- Configures as manual heat/cool, auto changeover, heat only or cool only
- Exclusive battery power monitor 5-year warranty
Display
- Large, 6-square-inch display
- Blue, lighted display for easier low-light viewing
- Larger, easy-to-read character size
- Large buttons for easy operation
Programming
- Universal – installer selectable system applications
- Choice of 7-day, 5/1/1 day programmable or non-programmable (installer selectable)
- 4 time and 4 temperature settings per program (2 setbacks) heat and cool, or selectable – 2 time and 2 temperature settings (1 setback)
- Energy savings up to 33%
- Patented pre-programmed schedule simplifies time and temperature programming
Comfort & Convenience
- Intuitive menu-driven setup, programming and operation, with audio prompt to confirm entries
- Permanent program retention during power loss
- Indefinite setpoint Hold or temporary temperature override
- Temporary temperature override will override program for two hours
- Auto heat/cool changeover option – automatically switches between heating and cooling programs
- Heating and cooling, heating only or cooling only configuration (installer selectable)
- Setpoint temperature “limited range” capable
- Furnace filter change reminder Maintains room temperature to within +/- 1°F
- The room temperature display can be recalibrated up to +/- 4°F
Performance
- Choice of battery-powered with optional power stealing assist or hardwired with battery backup
- Selectable Energy Management
- Recovery
- Meets California Building Code,
- Title 24
- Fast (FA) or slow (SL) heating cycle anticipation
- Exclusive “Call for Service” diagnostic indicator
- Compressor lockout protection
- Millivolt compatible
- Electric heat option
Terminal Designations
Dimensions
- 4.2″H x 6.4″W x 1.7″D
Thermal Specifications
- Setpoint Temperature Range: 45° to 99°F (7° to 37°C)
- Rated Differential: Heat 0.6°F; Cool 1.2°F
- Operating Ambient Temperature: 32° to 105°F (0° to 41°C)
- Operating Humidity Range: 90% non-condensing maximum
- Shipping Temperature Range: -40° to 150°F (-40° to 65°C)
Electrical Specifications
Rating
- Battery Power: mV to 30 VAC, NEC Class II, 50/60 Hz or DC
- Input Hardwire: 20 to 30 VAC
1.5 Amps (load per terminal)
2.5 Amps maximum load (all terminals combined) - Standard Systems
- Single Stage gas, oil, electric
- Single Stage heat pump
- Millivolt Systems
- Multi-Stage gas, oil, electric
- Multi-Stage heat pump
Accessories
- Remote Sensors:
Indoor – F145-1328
Outdoor – F145-1378 - Thermostat Guards:
Clear – F29-0198
Metal – F29-0220 (solid base) - Wallplates:
F61-2600 (8.1″W x 5.4H”)
F61-2634 (6.5″W x 5″H)
For Additional Information
Visit www.white-rodgers.com
Saint Louis, Missouri 314-553-3600
Markham, Ontario 905-948-3411
www.white-rodgers.com
www.emersonclimate.com
References:
Other Manual
EMERSON White-Rodgers 1F95-0671 Non-Programmable Installation and Operating Instructions
Download Manual
EMERSON White-Rodgers 1F95-0671 Non-Programmable specification sheet
EMERSON White-Rodgers 1F95-0671 Non-Programmable Thermostat specification sheet
Leave a Reply