Danfoss

Danfoss TP5001 battery powered programmable room thermostat User Guide

Danfoss TP5001 battery powered programmable room thermostat

LCD Overview

Symbols Function description
Current set day
1 Current on/off period
Current set time / parameter

number in setup

Room temperature

Temperature indication

Set temperature
Symbols Function description
Heating active
Frost protect active
Schedule mode
Away mode
RF Status (TP5001RF only)
Battery low indicator (TP5001B & TP5001RF only)

Buttons

Symbols Function description
Power on/off
Timer and program

operation

Mode change / option

setting

Temperature / option

setting selectors

Power ON/OFF

Turn the thermostat ON or OFF (standby) by pressing .

Setting the Temperature

  • Press < or > at any time to change the desired temperature value. SET is shown in the display.
  • When releasing < or >, the display returns to showing the actual temperature.
  • The adjustment step is 0.5 °C.

Select Away Mode

  • Press M to enter Away mode and will be displayed.
  • Away mode temperature can be set in parameter settings, P07.
  • Press M again to exit Away mode.

Set Date & Time

  • Press Year digit Flashes. Press < or > buttons to adjust year.
  • Press again; Month digit flashes. Press < or > buttons to adjust month.
  • Press again; Day digit flashes. Press < or > buttons to adjust day of the month.
  • Press again; Hour digit flashes. Press < or > buttons to adjust hour.
  • Press again; Minute digit flashes. Press < or > buttons to adjust minute.
  • Press to exit, automatic exit after 20 seconds, any changes are retained.

Frost Protection Temperature

  • You can switch the thermostat OFF (Standby) by alternately pressing . In OFF (Standby) mode, the thermo-stat is set to a Frost Protection temperature setting and will switch On only if the measured temperature falls below this temperature (5 °C by default).
  • The frost protect icon and current temperature will be displayed.

Advanced Programmable Timer

The Advanced Programmable Timer mode enables the setting of a timer-controlled program for automatic comfort temperature, and an energy-saving lower setback temperature if standard room comfort temperature is not required.
Example below for 5/2 day setup, 4 Temperature settings.

The function consists of 2 programs: 

P1 with 4 events in 5 days (Mon. Tue. Wed. Thu. Fri.)                                  P2 with 4 events in 2 days (Sat. Sun.).

P1: Press for 3 secs to display Mo. Tu. We. Th. Fr.

 

P1, Event 1:

1.     Use < or > to select the start hour.

2.     Press  to accept the setting.

3.     Use < or > to set the minute.

4.     Press  to accept the setting.

5.     Use < or > to select the temperature.

6.     Press to accept the setting.

 

P1, Event 2-4:

Repeat the Event 1 procedure for programming Event 2-4.

P2: Sa. Su. are now shown in the display.

 

P2, Event 1:

1.     Use < or > to select the start hour.

2.     Press  to accept the setting.

3.     Use < or > to set the minute.

4.     Press  to accept the setting.

5.     Use < or > to select the temperature.

6.     Press  to accept the setting.

 

P2, Event 2-4:

Repeat the Event 1 procedure for programming Event 2-4.

If schedule working mode is set to 24hr, only P1 program will be available, see parameter P01. Mo. to Su. will be set together with the same times and temperatures.

 

The thermostat will continue the 4-event program based on the present time and day.

If schedule working mode is set to 24hr, only P1 program will be available, see parameter P01. Mo. to Su. will be set together with the same times and temperatures.
The thermostat will continue the 4-event program based on the present time and day.

To set and change the room temperature temporarily:

  1. Press < or > at any time to change the desired temperature value. SET is shown in the display.
  2. When releasing the < or >, the display returns to showing the actual temperature. This temperature change is only temporary and will be maintained only until the next programmed setting!

A default program provides timer control if the customer does not create own programs:

Days Event 1 Event 2 Event 3 Event 4
Start time Temp. Start time Temp. Start time Temp. Start time Temp.
Mo. – Fr. 6:30 20° C 8:30 15° C 16:30 20° C 22:30 15° C
Sa. – Su. 7:30 20° C 9:30 15° C 16:30 20° C 22:30 15° C

Note: 24hr mode default program same as Mo. – Fr. above.

Set Control Parameters

  • Press M button for 6 seconds to enter the parameter setting mode. Press M for parameter selection and set the parameter range via < or >. Complete all adjustments.
  • To exit press , which is available for this purpose (automatic exit after 20 seconds with no operation).

The digits indicate the set value as follows:

No. Parameter settings Settings range Default

P01

Working mode

01: Manual

02: Schedule timer 5/2 day 03: Schedule timer 24hr

02

P02 Heat control mode 01: On/off load compensation 02: On/off standard 01

P03

Heat control start-up mode

01: Normal start control 02: Delayed start control 03: Optimised start control

01

P04 Temperature limit high Between low (P05) and 35° C 35° C
P05 Temperature limit low Between 5° C and high (P04) 5° C
P06 Frost protect temperature Between 5° C and 15° C 5° C
P07 Away mode temperature Between low (P05) and high (P04) 18° C
P08 Timer display 01: 24hr

02: 12hr

24hr
P09 Service due setup Installer setting only
P10 RF Pairing (TP5001RF only) 00: RF pairing mode off 01: RF pairing mode on 00
P11 Auto daylight saving 01: On

02: Off

01

Error Messages

E1 Sensor failure
EE EEPROM failure
Lo Measured temperature below 0 °C
Hi Measured temperature above 50 °C
E3 RF Pairing failed
E4 RF Signal lost

Danfoss Limited
Heating Segment heating.danfoss.co.uk
+44 (0)1895 6117000
E-mail: customerservice.uk@danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
All trademarks in this materia are property of the respective companies. Danfoss and all Danfoss logotypes are trademarks of Danfoss A/S. All rights reserved.

Reference

Download Manual

Honeywell Home T3 PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET

Other Manual

Danfoss TP5001 Electronic Room Thermostats Technical Specification Data Sheet

Danfoss TP5001 wireless programmable thermostat User Guide

Danfoss TP5001 battery-powered programmable room thermostat User Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago