LCD Overview

Symbols Function description
Danfoss-TP5001-battery-powered-programmable-room-thermostat-1 Current set day
1Danfoss-TP5001-battery-powered-programmable-room-thermostat-2 Current on/off period
Danfoss-TP5001-battery-powered-programmable-room-thermostat-3 Current set time / parameter

number in setup

Danfoss-TP5001-battery-powered-programmable-room-thermostat-4 Room temperature
Danfoss-TP5001-battery-powered-programmable-room-thermostat-5  

Temperature indication

Danfoss-TP5001-battery-powered-programmable-room-thermostat-6 Set temperature
Symbols Function description
Danfoss-TP5001-battery-powered-programmable-room-thermostat-7 Heating active
Danfoss-TP5001-battery-powered-programmable-room-thermostat-8 Frost protect active
Danfoss-TP5001-battery-powered-programmable-room-thermostat-9 Schedule mode
Danfoss-TP5001-battery-powered-programmable-room-thermostat-10 Away mode
Danfoss-TP5001-battery-powered-programmable-room-thermostat-11 RF Status (TP5001RF only)
Danfoss-TP5001-battery-powered-programmable-room-thermostat-12 Battery low indicator (TP5001B & TP5001RF only)

Buttons

Symbols Function description
Danfoss-TP5001-battery-powered-programmable-room-thermostat-13 Power on/off
Danfoss-TP5001-battery-powered-programmable-room-thermostat-14 Timer and program

operation

Danfoss-TP5001-battery-powered-programmable-room-thermostat-15 Mode change / option

setting

Danfoss-TP5001-battery-powered-programmable-room-thermostat-16 Temperature / option

setting selectors

Power ON/OFF

Turn the thermostat ON or OFF (standby) by pressing Danfoss-TP5001-battery-powered-programmable-room-thermostat-13.

Setting the Temperature

  • Press < or > at any time to change the desired temperature value. SET is shown in the display.
  • When releasing < or >, the display returns to showing the actual temperature.
  • The adjustment step is 0.5 °C.

Select Away Mode

  • Press M to enter Away mode andDanfoss-TP5001-battery-powered-programmable-room-thermostat-10 will be displayed.
  • Away mode temperature can be set in parameter settings, P07.
  • Press M again to exit Away mode.

Set Date & Time

  • Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14Year digit Flashes. Press < or > buttons to adjust year.
  • Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14again; Month digit flashes. Press < or > buttons to adjust month.
  • Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14again; Day digit flashes. Press < or > buttons to adjust day of the month.
  • Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14again; Hour digit flashes. Press < or > buttons to adjust hour.
  • Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14again; Minute digit flashes. Press < or > buttons to adjust minute.
  • Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14to exit, automatic exit after 20 seconds, any changes are retained.

Frost Protection Temperature

  • You can switch the thermostat OFF (Standby) by alternately pressingDanfoss-TP5001-battery-powered-programmable-room-thermostat-13 . In OFF (Standby) mode, the thermo-stat is set to a Frost Protection temperature setting and will switch On only if the measured temperature falls below this temperature (5 °C by default).
  • The frost protect icon and current temperature will be displayed.

Advanced Programmable Timer

The Advanced Programmable Timer mode enables the setting of a timer-controlled program for automatic comfort temperature, and an energy-saving lower setback temperature if standard room comfort temperature is not required.
Example below for 5/2 day setup, 4 Temperature settings.

The function consists of 2 programs: 

P1 with 4 events in 5 days (Mon. Tue. Wed. Thu. Fri.)                                  P2 with 4 events in 2 days (Sat. Sun.).

P1: Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14 for 3 secs to display Mo. Tu. We. Th. Fr.

 

P1, Event 1:

1.     Use < or > to select the start hour.

2.     Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14 to accept the setting.

3.     Use < or > to set the minute.

4.     Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14 to accept the setting.

5.     Use < or > to select the temperature.

6.     Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14 to accept the setting.

 

P1, Event 2-4:

Repeat the Event 1 procedure for programming Event 2-4.

P2: Sa. Su. are now shown in the display.

 

P2, Event 1:

1.     Use < or > to select the start hour.

2.     Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14 to accept the setting.

3.     Use < or > to set the minute.

4.     Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14  to accept the setting.

5.     Use < or > to select the temperature.

6.     Press Danfoss-TP5001-battery-powered-programmable-room-thermostat-14 to accept the setting.

 

P2, Event 2-4:

Repeat the Event 1 procedure for programming Event 2-4.

If schedule working mode is set to 24hr, only P1 program will be available, see parameter P01. Mo. to Su. will be set together with the same times and temperatures.

 

The thermostat will continue the 4-event program based on the present time and day.

If schedule working mode is set to 24hr, only P1 program will be available, see parameter P01. Mo. to Su. will be set together with the same times and temperatures.
The thermostat will continue the 4-event program based on the present time and day.

To set and change the room temperature temporarily:

  1. Press < or > at any time to change the desired temperature value. SET is shown in the display.
  2. When releasing the < or >, the display returns to showing the actual temperature. This temperature change is only temporary and will be maintained only until the next programmed setting!

A default program provides timer control if the customer does not create own programs:

Days Event 1 Event 2 Event 3 Event 4
Start time Temp. Start time Temp. Start time Temp. Start time Temp.
Mo. – Fr. 6:30 20° C 8:30 15° C 16:30 20° C 22:30 15° C
Sa. – Su. 7:30 20° C 9:30 15° C 16:30 20° C 22:30 15° C

Note: 24hr mode default program same as Mo. – Fr. above.

Set Control Parameters

  • Press M button for 6 seconds to enter the parameter setting mode. Press M for parameter selection and set the parameter range via < or >. Complete all adjustments.
  • To exit pressDanfoss-TP5001-battery-powered-programmable-room-thermostat-14 , which is available for this purpose (automatic exit after 20 seconds with no operation).

The digits indicate the set value as follows:

No. Parameter settings Settings range Default
 

P01

 

Working mode

01: Manual

02: Schedule timer 5/2 day 03: Schedule timer 24hr

 

02

P02 Heat control mode 01: On/off load compensation 02: On/off standard 01
 

P03

 

Heat control start-up mode

01: Normal start control 02: Delayed start control 03: Optimised start control  

01

P04 Temperature limit high Between low (P05) and 35° C 35° C
P05 Temperature limit low Between 5° C and high (P04) 5° C
P06 Frost protect temperature Between 5° C and 15° C 5° C
P07 Away mode temperature Between low (P05) and high (P04) 18° C
P08 Timer display 01: 24hr

02: 12hr

24hr
P09 Service due setup Installer setting only
P10 RF Pairing (TP5001RF only) 00: RF pairing mode off 01: RF pairing mode on 00
P11 Auto daylight saving 01: On

02: Off

01

Error Messages

E1 Sensor failure
EE EEPROM failure
Lo Measured temperature below 0 °C
Hi Measured temperature above 50 °C
E3 RF Pairing failed
E4 RF Signal lost

Danfoss Limited
Heating Segment heating.danfoss.co.uk
+44 (0)1895 6117000
E-mail: [email protected]
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
All trademarks in this materia are property of the respective companies. Danfoss and all Danfoss logotypes are trademarks of Danfoss A/S. All rights reserved.

Reference

Download Manual

Honeywell Home T3 PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET

Other Manual

Danfoss TP5001 Electronic Room Thermostats Technical Specification Data Sheet

Danfoss TP5001 wireless programmable thermostat User Guide

Danfoss

Danfoss TP5001 battery-powered programmable room thermostat User Guide

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *