Danfoss TP5001 wireless programmable thermostat User Guide

Danfoss

Danfoss TP5001 wireless programmable thermostat

Danfoss-TP5001-wireless-programmable-thermostat-PRODUCT

What is a programmable room thermostat?

A programmable thermostat allows you to set times at which you want you heating to be at a specific temperature. A room thermostat works by sensing the air temperature and switching on the heating when the air temperature falls below the thermostat setting, switching it off once this set temperature has been reached. The TP5001 programmable room thermostat has made intelligent heating control easier than ever before.

Setting Time and Date

  1. PressDanfoss-TP5001-wireless-programmable-thermostat-FIG.2 button , the screen will change to show the current year.
  2. Adjust using Danfoss-TP5001-wireless-programmable-thermostat-FIG.3 to set the correct year. Press to accept. Repeat step b to set month and time settings.

Advanced Programmable Timer

Advanced Programmable Timer
The Advanced Programmable Timer mode enables the setting of a timer-controlled program for automatic comfort temperature, and an energy-saving lower setback temperature if standard room comfort temperature is not required.
Example below for 5/2 day setup, 4 Temperature settings The function consists of 2 programs:
P1 with 4 events over weekdays (Mon. To. Fri.)
P2 with 4 events over weekends (Sat. Sun.).
P1: PressDanfoss-TP5001-wireless-programmable-thermostat-FIG.2 once to activate product. The pressDanfoss-TP5001-wireless-programmable-thermostat-FIG.2for 3 seconds to display Mo. Tu. We. Th. Fr.

P1, Event 1:

1.  Use Danfoss-TP5001-wireless-programmable-thermostat-FIG.3 to select the start hour.

2.  PressDanfoss-TP5001-wireless-programmable-thermostat-FIG.2 to accept the setting.

3.  UseDanfoss-TP5001-wireless-programmable-thermostat-FIG.3 to set the minute.

4.  PressDanfoss-TP5001-wireless-programmable-thermostat-FIG.2 to accept the setting.

5.  UseDanfoss-TP5001-wireless-programmable-thermostat-FIG.3to select the temperature.

6.  Press Danfoss-TP5001-wireless-programmable-thermostat-FIG.2 to accept the setting.

P1, Event 2–4:

Repeat the Event 1 procedure for programming Events 2–4.

P2: Sa. Su. are now shown in the display.
P2, Event 1:1.  Use  Danfoss-TP5001-wireless-programmable-thermostat-FIG.3 to select the start hour2.  PressDanfoss-TP5001-wireless-programmable-thermostat-FIG.2to accept the setting.

3.  Use Danfoss-TP5001-wireless-programmable-thermostat-FIG.3to set the minute.

4.  PressDanfoss-TP5001-wireless-programmable-thermostat-FIG.2to accept the setting.

5.  UseDanfoss-TP5001-wireless-programmable-thermostat-FIG.3to select the temperature.

6.  Press Danfoss-TP5001-wireless-programmable-thermostat-FIG.2 to accept the setting.

P2, Event 2–4:

Repeat the Event 1 procedure for programming Event 2–4.

If the working mode is set to 24hr, only P1 program will be available (same times each day of the week), to change this see the User settings section of this document.

Display and Navigation Details

Danfoss-TP5001-wireless-programmable-thermostat-PRODUCT

Display & Navigations

Danfoss-TP5001-wireless-programmable-thermostat-FIG.1

Setting/Changing the Temperature

  1. Press Danfoss-TP5001-wireless-programmable-thermostat-FIG.3 at any time to change the desired temperature value. SET is shown in the display.
  2. When releasing theDanfoss-TP5001-wireless-programmable-thermostat-FIG.3after around 5 seconds, the display returns to showing the actual temperature. This temperature change is only temporary and will be maintained only until the next programmed setting.

Holiday Mode

Holiday Mode selects the comfort temperature typically when the home is unoccupied

  1. Press M to enter into Holiday mode Danfoss-TP5001-wireless-programmable-thermostat-FIG.4and will be displayed.
  2. Holiday mode temperature can be set in User settings, 07.
  3. Press M again to exit Holiday mode.

Frost Protection Temperature and Reset

  1. The thermostat is turned OFF (Standby) mode by pressing . In OFF (Standby) mode the thermostat is set to Frost Protect temperature setting and will switch the output On if the measured temperature falls below the frost protection temperature setting.
  2. Frost protect icon and current temperature will be display.
  3. At this point if button is pressed for 10 seconds Continuously then the thermostat will be reset.

User Settings

  1. Press M button once to illuminate screen, next press M for 6 seconds to enter the User setting mode. Press M for parameter selection and set the parameter range via Danfoss-TP5001-wireless-programmable-thermostat-FIG.3 . Complete all adjustments.
  2. To exit pressDanfoss-TP5001-wireless-programmable-thermostat-FIG.2 , automatic exit after 20 seconds when no button is pressed.
 User Settings                                                                                                
a.  Press M button once to illuminate screen, next press M for 6 seconds to enter the User setting mode. Press M for parameter selection and set the parameter range via  or . Complete all adjustments.

b.  To exit press , automatic exit after 20 seconds when no button is pressed.

No. Parameter settings Settings range Default
 

01

 

Working mode

01: Manual

02: Schedule timer 5/2 day 03: Schedule timer 24hr

 

02

02 Heat control mode 01: On/off load compensation 02: On/off standard 01
 

03

Heat control start-up mode 01: Normal start control 02: Delayed start control 03: Optimised start control  

01

04 Temperature limit high Between low (05) and 35° C 35° C
05 Temperature limit low Between 5° C and high (04) 5° C
06 Frost protect temperature Between 5° C and 15° C 5° C
07 Holiday mode temperature Between low (05) and high (04) 18° C
08 Timer display 01: 24hr

02: 12hr

24hr
09 Service due setup Installer setting only
10 RF Pairing (TP5001RF only) 00: RF pairing mode off 01: RF pairing mode on 00
11 Auto daylight saving 01: On

02: Off

01

Danfoss A/S
Heating Segment
danfoss.com
+45 7488 2222
E-mail: [email protected]

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

OTHER MANUALS:

Danfoss TP5001 battery-powered programmable room thermostat User Guide

Danfoss TP5001 Electronic Room Thermostats Technical Specification Data Sheet

Danfoss

Danfoss TP5001 wireless programmable thermostat User Guide


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *