A Comfort Heat floor heating system has been installed in your floor. Floor heating warms from the ground up providing an unparalleled feeling of comfort. This heating system is controlled by an electronic thermostat and floor sensor for optimum temperature control and efficiency.
MTD3 DETAILS
The MTD3 thermostat is a manual ON/OFF thermostat you set to a fixed temperature. Once the floor reaches the set temperature, the system will turn ON and OFF automatically maintaining the fixed temperature
PRIOR TO TURNING ON
Concrete slabs, screeds and tile glues must be fully cured before turning the heating system on. Wait at least 3 weeks and when turning on for the first time, increase the floor temperature gradually over 2-3 days Under carpet and timber systems can be turned on once installation is complete
AREAS | TILE [BATH] | TILE [LARGE AREA] | INSLAB | CARPET | TIMBER |
SUGGESTED TEMPERATURE | 24-28ºC | 21-22ºC | 21ºC | 19-21ºC | 24ºC |
CABLE WARRANTY | 10 years | 10 years | 10 years | 5 years | 5 years |
TURNING ON
RUNNING GUIDELINES
Due to the MTD3 being a manual thermostat, it is typically used in small areas, at low temperatures, and not turned ON/ OFF daily. The temperature is set and the thermostat is left to maintain a fixed temperature 24/7. The MTD3 is also used with large in-slab areas which are connected to a dedicated off-peak circuit. Slabs have a large thermal mass and the ability to store heat for long periods of time. Heating slabs during off-peak times is a cost efficient heating option. Please note it must be a dedicated off-peak circuit. Electricity calculated via smart meters and time of use require a digital MWD5 thermostat providing the ability to programme heating at off peak times.
CHILD LOCK
CHANGE FRONT COVER
The MTD3 comes with an alternate plain cover plate for a minimal look. To change the cover;
SETTING PARAMETER VALUES – MENU MODE
MENU | DESCRIPTION | SETTINGS | DEFAULT |
APP | Choose sensor to control heating | A / F / C / AF / AE | F [Floor] |
SCA | Set the min. and max. temperatures | 0ºC – 40.0ºC | 0ºC – 40.0ºC |
tP | Temperature read out | Flo / ro | Flo [floor] |
LCd | Select; Temp. setting & Display setting | C / F / nu & SP / tP / CL | C [celcius] & SP[setpoint] |
AdJ | Calibrate the measured room temperature | ||
nSb | Night setback temperature | 2.0ºC – 8.0ºC | 5ºC |
dEF | Frost protection | 5.0ºC – 10.0ºC | 8ºC |
PWM | Duration of the heating periods | oFF / on / Aut | |
PLi | Power limit | 0 – 30min | 0 |
tiME | Time and ev ent setting | ModE / dAY / Hour / Min | |
SW | Software v ersion | ||
donE | Sav e settings and Exit menu |
To enter menu mode;
If an error message occurs, the thermostat will display one of the following errors;
Comfort Heat
DOWNLOAD MANUALS:
Comfortheat MTD3 Programmable Thermostat Operating Manual
OTHER MANUALS:
Comfortheat MTD3 Programmable Thermostat User Manual
Comfortheat MTD3 THERMOSTAT General Wiring Diagram
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…