Wall Locations
The thermostat should be installed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulation
Subbase Installation
Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat, then push gently until the thermostat snaps in place
Battery installation is optional if thermostat is hardwired (Rand C terminal connected to 24V power).
CTerminal
The C (common wire) terminal does not have to be connected when the thermostat is powered by batteries
Wire Specifications
Use shielded or non-shielded 18-22 gauge thermostat wire
Terminal Designations
This thermostat is shipped from the factory to operate a conventional heating and cooling system. This thermostat may also be configured for a heat pump system. See theuheat pump” configuration step on page 14 of this manual to configure the thermostat for heat pump applications
RC | Transformer power (cooling) | Transformer power (cooling) | Transformer power (cooling) |
RH | Transformer power (heating) | Transformer power (heating) | Transformer power (heating) |
C | Transformer common | Transformer common | Transformer common |
B | Reversing valve / configerable terminal | Reversing valve / configerable terminal | Reversing valve / configerable terminal |
0 | Reversing valve / configerable terminal | Reversing valve / configerable terminal | Reversing valve / configerable terminal |
G | Fan relay | Fan relay | Fan relay |
W/E | First stage of heat | Emergency Heat | First stage of auxiliary heat |
y | First stage of coo l | First stage of heat&cool | First stage of heat&cool |
Y2 | Second stage of cCXJI | N/A | Second stage of heat & cool |
W2 | Second stage of heat | Auxiliary heat | Secodn stage of auxiliary heat |
Note: Only press DONE key when you want to exit the Technician Setup options
Swing Setting Tip
The second stage will turn on at 2x the swing setting. The second stage will turn off when 1x the swing is reached. For example, if the swing setting is 0.5 degrees for heating and the thermostat is set at 70°F, the first stage will turn on at approximately 69.5 “F. The second stage will turn on at 69°F. The second stage will turn off at 69.s°F and the first will turn off at 70.5 °F. If the third stage is used, it will turn on at 68.5 °F and turn off a approximately 69°F.
A Note About Keypad Lockout:
The function of activating your lockout choice takes place after you have exited tech setup. To lock or unlock the keypad hold down the MENU for 3 seconds
Contractor Call Number Note:
If contractor call number is selected ON, your phone number will show in the display if there has been a continuous call for heating or cooling for 24 hours or if the FAN button is held down for 3 seconds. To remove the phone number from the display, hold the fan button down for 3 seconds
Set Time
Set Program Schedule
To customize your 5+ 1 + 1 program schedule, follow these steps Weekday:
Saturday:
Repeat steps 4 thru 7 for the Saturday WAKE time period, LEAVE time period, RETURN time period, and for the Saturday SLEEP time period.
Sunday:
Repeat steps 4 thru 7 for the Sunday WAKE time period, LEAVE time period, RETURN time period, and for the Sunday SLEEP time period.
To customize your 7 Day Program schedule, follow these steps:
All of our programmable thermostats are shipped with an energy saving pre-program. Your thermostat can be programmed to have all the weekdays the same, a seperate program for Saturday, and a seperate program for Sunday. There are four time periods for each program (WAKE, LEAVE, RETURN, SLEEP}.
A Note About Auto Changeover:
If in Auto ~ou have the ability to switch between Auto Heat or Auto Coo by pressing the System key. This can be done once the current mode has reached its set-point. For exami:,le: If in Auto Heat, the heat setpoint must be satisfied before the thermostat will allow you to switch to Auto Cool. You can switch out of Auto by holdini down the System key. To get back into Auto, you must toggle t e System key to Auto.
A Note About Programmable Fan:
The programmable fan feature will run the fan continuously during any time period it is programmed to be on. This is the best way to keep the air circulated and to eliminate hot and cold spots in your building.
Reminders Note:
Once a Reminder has been turned on and set, the elapsed time can be checked by navigating to it’s tech setup step. The elapsed time will then appear in the text field. It can also be reset at that time by a press and hold of the third button from the left for 3 seconds. Resetting an expired Reminder can be done without entering tech setup, by a press and hold of the 3rd button from the left for 3 seconds.
Weekday | Wa ke | 6AM | 70°F (21°() | 75°F (24°() |
Leave | 8AM | 62 ° F ( 17°( ) | 83 ° F (28″() | |
Ret urn | 6PM | 70 ° F (2 1°( ) | 75° F (24°() | |
Slee p | 10 PM | 62 ° F ( 17°( ) | 78°F (26°( ) | |
Saturd ay | Wake | 6AM | 70°F (21 °( ) | 75°F (24°( ) |
Leave | 8AM | 62 ° F ( 17°( ) | 83 ° F (28″() | |
Ret urn | 6PM | 70°F (21°() | 75° F (24°() | |
Slee p | 10 PM | 6 2° F(l r c J | 78°F (26″() | |
Sund ay | Wake | 6AM | 70°F (2 1°( ) | 75 ° F (2 4“( ) |
leave | BAM | 62 ° F ( 17°( ) | 83 ° F (28″() | |
Ret urn | 6 PM | 70 °F (2 1°( ) | 75° F (24°() | |
Slee p | 10 PM | 6 2 ° F (1 7° C) | 78 ° F (26°() |
Breeze33 Products LLC (Breeze33) warrants to the ORIGINAL PURCHASER that its thermostats shall be free from defects in material and workmanship under normal use and service for a five (5) years. This warranty cannot be transferred- it is extended only to the original Purchaser or First User of the Product. By accepting and keeping this Product you agree to all of the warranty terms and limitations of liability described below. Breeze33’s obligations under the warranty set forth above shall be to replace any Breeze33 Thermostat which is defective.
WHAT IS NOT COVERED?
The warranty above does not cover and Breeze33 is not liable for, (i) installation, (ii) any labor charges or (iii) products which have been damaged as a result of any accident, misuse, abuse, neglect, improper installation or maintenance, the use of abrasive or organic solvent cleaners, modification, failure to use the register, grille, or diffuser in accordance with instructions provided by Breeze33.
HOW TO OBTAIN WARRANTY SERVICE
Contact our warranty department at 740-314-4404 to report the defect. Return failed product with proof of purchase,your name, and address within 30 days offailure to:
LIMITATION OF LIABILITY
Breeze33’s liability on any claim of any kind, including, without limitation, warranty, negligence and/or breach of contract, shall in no case exceed the purchase price paid by the Customer. IN NO EVENT SHALL BREEZE33 BE LIABLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL (INCLUDING, WITHOUT LIMITATION, DAMAGE TO PROPERTY) OR PUNITIVE DAMAGES, DAMAGES IN THE NATURE OF PENALTIES OR SIMILAR OR RELATED DAMAGES OF ANY KIND.
DISCLAIMER OF WARRANTIES
BREEZE33 EXPRESSLY DISCLAIMS ALL WARRANTIES, EXCEPT AS EXPLICITLY STATED HEREIN, TO THE FULLEST EXTENT PERMITTED BY LAW, WHETHER WRITTEN, ORAL, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF PERFORMANCE, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT. THIS DISCLAIMER INCLUDES ANY ORAL WARRANTIES OR REPRESENTATIONS MADE OR IMPLIED BY ANY AGENT, EMPLOYEE, SUBCONTRACTOR, MANAGER, DIRECTOR AND/OR REPRESENTATIVE OF BREEZE33.
DOWNLOAD MANUALS:
Breeze33 BZ33-302TSP Programmable Thermostat Installational Manual
Breeze33 BZ33-302TSP Programmable Thermostat Installational Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…