This product provides communication between a boiler without an EMS function (Energy Management System) and:
This product converts the following protocols to EMS and viceversa:
Functional capability can be lost, if protocols are converted. This product may also be used:
The standard delivery consists of (fig. 1):
This product has the following connection possibilities fig. 2):
This product has a warranty period of 2 years.
This product is in accordance in design and operation with the European Directives and the supplementary national requirements. The conformity is indicated by the CE mark. You can ask for a copy of the declaration of conformity for this product. For this see the contact address on the back cover of these instructions.
Environmental protection is a key company principle for the Bosch Group. Product quality, economical profitability and environmental protection are equally important to us. We strictly adhere to environmental laws and rules. To protect the environment, we adapt, subject to economical considerations, the best possible technology and materials.
Packaging
In our packaging, we consider all country specific recycling systems to guarantee optimal recycling. All of our packaging materials are environmentally friendly and recyclable.
Old electrical and electronic appliances
Electrical or electronic devices that are no longer serviceable must be collected separately and sent for environmentally compatible recycling (in accordance with the European Waste Electrical and Electronic Equipment Directive). To dispose of old electrical or electronic appliances, you should use the return and collection systems put in place in the country concerned.
The minimum requirements for installation of this product are:
See the installation instructions for the boiler for more information on connecting the thermostat.
Thermostat and boiler connection
The “thermostat” and “boiler” cable clamps are not polarity sensitive.
The EMS-bus is connected in the following way (fig. 4):
An on-off switching unit can be connected through the zero volt contact (fig. 5):
The default connection is COM-NO. Following a heat demand, the NO contact closes.
The EasyControl adaptor will start initialising (fig. 7). The steps in table 1 are run through automatically.
Table 1 LED indication during initialisation
# | LED indication | The EasyControl adaptor: |
1 | Flashing red | … is receiving power and is waiting for protocol detection. |
2 | Flashing blue | … is processing protocol detection. |
3 | Constantly blue | … has detected a supported protocol and is initialising the internal database. |
4 | Constantly green | … has received data from the boiler as well as from the thermostat. |
5 | Dimmed green | … is in operation. |
Table 2 Technical data, module
Volume | Unit | Value |
Voltage supply | VDC | 20 |
Nominal electrical load | W | < 2.5 |
Dimensions (width x height x depth) | mm | 134 × 115 × 37 |
Weight | g | 230 |
Permissible ambient temperature range | °C | 0 – 50 |
Max. storage temperature | °C | 0 – 60 |
Permissible relative humidity | % | 10 – 90 |
IP classification
| IP20 |
Table 3 Technical data, zero volt contact
Volume | Unit | Value |
Contact load (min.) @ 18VDC | mA | 10 |
Contact load (max.) @ 250VAC | A | 5 |
Cable diameter (max.) | mm2 | 2.5 |
Cable length (max.) EasyControl adaptor – boiler | m | 3 |
Cable length (max.) EasyControl adaptor – thermostat | m | 100 |
Table 4 Malfunctions
LED | Error | Solution | |
Blinking alternating red and blue | No boiler detected. | ▶ ▶ ▶ ▶ | Turn on the boiler. Check the cable clamps between the power adaptor and the connection to the boiler. Check the 2-wire cable. Refer to the boiler installation instructions. |
Constantly red | Short circuit connection to the thermostat. | The boiler is turned off: ▶ Turn on the boiler. ▶ Check all connections. | |
No communication with the boiler. | The boiler is switched on: ▶ Remove the EasyControl adaptor power adaptor from the socket, wait at least 10 seconds, and reconnect it. | ||
Constantly blue | No communication with the thermostat. | ▶ ▶ ▶ | Turn on the boiler. Check the cable clamps between the power adaptor and the thermostat. Check the 2-wire cable to the thermostat. |
Out | No power. | ▶ ▶ | Connect the EasyControl adaptor power supply. Replace the power adaptor. |
US United States and Canada Bosch Thermotechnology Corp. 50 Wentworth Avenue Londonderry, NH 03053
Tel. 603-552-1100
Fax 603-965-7581
www.boschheatingandcooling.com
Download Manual: Worcester Bosch EasyControl Adapter Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…