The thermostat 02950 is designed to control room temperature by acting on the control circuit of the burner or circulation pump (heating) or on the control circuit of the air conditioner (air conditioning), ensuring an ideal temperature. Thanks to a touchscreen display with an extremely user-friendly graphical interface, the user can manage the system easily and comprehensively while keeping the environment in a state of energy-saving.
Display
The touchscreen display allows you to control the system using the following buttons and icons:
N.B.: The field/value being edited is highlighted by the field/value itself flashing.
Symbols
Depending on the different operating modes, the following icons could also be displayed:
Ecometer
On the left-hand side of the display, there is a set of icons called the “ECOMETER” that provides an overview of the expected consumption. The color of the display, if configured in “ECO” mode, shows the expected consumption provided by the ECOMETER via the background color (see 4.9). This indicator facilitates system management geared to energy saving by associating a different color depending on the estimated forecast.
Locking the interface via PIN
The thermostat lets you set a password (see par. 4.12) which inhibits any change to the operating mode (eg switching from Manual to OFF), limits setting the temperature values, and, more generally, blocks
access to the configuration menu. This feature is useful to prevent the thermostat from being used by unauthorized persons: the device prompts you to enter the PIN, indicating a shutdown.
Operating mode
The thermostat 02950 is able to adjust the temperature according to the following operating modes:
Switched off (OFF)
In this mode, the thermostat is turned off and you cannot make any adjustments; in this case, the icon off is displayed above the temperature indicator.
For heating-only systems this mode is typically used in the summer.
Manual (ON)
This is the “traditional” operating mode. The thermostat controls the room temperature and takes it to the value set by the user.
The set point can always be changed via
Only if the colour set for the display is white (C0) or ECO, see par. 8.9.
The selection is confirmed by touching
Away
This mode is useful to achieve energy savings quickly and effectively whenever the user leaves the regulated room. In “Away” mode the system makes the adjustment according to the “away temperature” setpoint
(see para. 4.4.2) which is more cost-effective than the manual setpoint
Activation of this mode is identified by the
To exit and return to Manual mode touch
Nighttime reduction
This is the typical mode to use at night to reduce system consumption significantly. In “Nighttime reduction” mode the device reduces the consumption of the system, taking the room temperature to a lower value (or higher, if on air-conditioning) than the Manual mode by degrees (see par. 4.4.4). “Nighttime reduction” is activated starting from Manual mode by touching
Activation of this mode is identified by the icon
To exit and return to Manual mode
Antifreeze
This mode, which can only be activated when the system is operating in heating mode (see par. 4.3), lets you set a minimum temperature value ( setpoint) to avoid damage to the pipework or to keep it from
falling below a certain safety level when you are away for lengthy periods in the winter. The “antifreeze” mode is activated directly from the Settings menu (see par. 4.1). Once activated, antifreeze mode is identified by the icon
Remote reduction is a useful way to “centralize” energy saving if there are multiple 02950 thermostats in different rooms of the same house.It is similar to Nighttime reduction mode with the only difference being that activation is by remote control. Example: Before going to bed, using a simple switch, all the thermostats in the house are set onto “reduction” at the same time. This mode comes into operation when the multi-function input is activated only if this has been suitably configured by your installer. The multifunction input is activated solely when the thermostat is in Manual mode. In “remote reduction” mode, the device sets the temperature to a value below Tcomfort. In this condition the display and its buttons have limited functions; access to the settings menu is disabled and you can only change the temperature setpoint within a limited range. The “Remote reduction” mode is identified by the
On disabling the multi-function input, the thermostat returns to the previously set mode and the user can again manage the device completely.
Remote activation
This mode is typically used in applications where you want to remotely enable or disable temperature control of a room and limit the functions that can be performed by the user (typical mode for hotel room
management). This mode comes into operation when the multi-function input is activated only if this has been suitably configured by the installer. In “remote activation” mode, the device sets the temperature to a value equal to Tcomfort. In this condition the display and its buttons have limited functions; accIn “remote activation” mode, the device sets the temperature to a value equal to Tcomfort. In this condition the display and its buttons have limited functions; access to the settings menu is disabled and you can only change the temperature setpoint within a limited range. The “Remote activation” mode is identified by the
Settings menu
From the settings menu you can configure all the features of the thermostat. On the main screen (see Fig. 1) tap the
Touching
Operating mode setting
This menu is used to select the operating mode of the device:
Unit of measurement setting
The menu lets you set the unit of measurement used for the temperature (°C or °F)
Using
Heating/air-conditioning setting
This menu is for the sole use of the installer.
Temperature set point setting
This menu is for the sole use of the installer.
Calibration setting
This menu is for the sole use of the installer.
External probe settingThis menu is for the sole use of the installer.
Multi-function input setting
This menu is for the sole use of the installer.
OnOff/PID setting
This menu is for the sole use of the installer.
Colour setting
This menu is used to select the backgroupd colour of the display. In addition to the four default colours, you can set a colour to your choice selected from the full range o colours, or set “ECO” mode in which the display colour is a clue to the expected level of consumption in the building.
Via
ECO mode therefore does not display the colour as a function of the temperature measured at that time but only in relation to the setpoint. Lastly,
Standby brightness level setting
The menu lets you set the brightness level when the thermostat is in standby mode Via
While scrolling through the values, when the selection stops on a certain level, the brightness of the display will, for approximately 2 s, take on the brightness corresponding to the selected level in order to
allow the user to check the visual effect. Lastly, tap
Info
This menu is for the sole use of the installer.
Lock/unlock PIN setting
This menu lets you add/change the password to inhibit use of the thermostat. Using
IMPORTANT: Take care to note down the password so that you can use it again for the device when needed
Alarms
The thermostat is capable of displaying an alarm condition associated with the use of the external temperature probe; in this situation, the device controls the system independently so the alarm will cease in a matter of minutes.
The device features a touchscreen display with capacitive buttons and therefore requires you to be gentle during the cleaning phase. Avoid using aggressive products. Clean the display with a special cloth for cleaning lenses.
Main characteristics
Regulatory compliance
Viale Vicenza, 14 – 36063 Marostica VI – Italy Tel. +39 0424 488 600 – Fax (Italy) +39 0424 488 188 Fax (Export) +39 0424 488 709 www.vimar.com
Download Manual:
VIMAR 02950 Touchscreen Thermostat Instruction Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…