The OPTIMUM VIBE – Model OP-WFSTAT is a radio frequency programmable thermostat, with dual radio frequency / WiFi receiver. It MUST be installed by a qualified person, in accordance with best pracitse and current IEE wiring regulations. Before programming, complete all set-up instructions.
The transmiter is battery-powered (2 x AAA alkaline); the receiver is mains-powered, with volt-free switching. The control set uses the license – free 868 MHz radio frequency to communicate between transmiter and receiver, and the ISM 2.4 GHz frequency to communicate with your WiFi router, compliant with WLAN 802.11 b/g/n
Installation procedure: transmiter and receiver positoning
The receiver should normally be wall-mounted close to the boiler, and should share a mains supply from the same circuit that powers the heater / boiler. However avoid locating it directly next to the boiler’s case – see 1 below. The transmiter should be located within the property bearing in mind the following requirements:
The transmiter has an in-built temperature sensor, which it uses to detect ambient temperature, and calculates whether to send a demand or no-demand signal to the receiver. The transmiter should be located in a main living area, where it is visible, has a free air-flow and is not unduly influenced by draughts or extraneous heat sources: e.g. radiator / direct sunlight / lamp— please refer to the diagrams below:
Transmiter – installation
Place 2 x AAA alkaline batteries in the battery compartment at the back of the transmiter; ensure correct polarity. Set the time and day: Atfer inserting batteries, the transmitier will jump totime-settng mode, or during normal operation, touch SET for five seconds, change the minutes, touch SET, change the hours, touch SET, change the day, touch SET. Then touch the ON/OFF icon to put in run mode. Full set-up can be completed later.
The transmiter can be wall-mounted, or placed on a table-top or counter, using the back-plate or the stand includ-ed in the carton. If wall-mounting, fix the back-plate to the wall observing the UP ↑ ↑ marks, align the top two recesses on the back of the transmiter, to the top two lugs on the back-plate, then rotate downwards to ‘click’ the other two lugs in place. Reverse this procedure to remove the transmiter from the back-plate. Note that – if you hold the transmiter for longer than a few seconds, it will start to detect your body temperature, rather than the ambient room temperature, and this will affect the calculation of demand / no demand for heat. Replace the transmiter onto the back-plate or stand so that it will again start to detect the ambient room temperature.
Receiver – installation
The receiver should be wall-mounted in a clean, dry environment. It is a class II control, suitable for ambient temperature from 0 to 500C. It has 60mm wall-fixing centres which are compafble with standard back-boxes. A back-plate channel is provided if wiring has to be surface-run. The receiver requires a 230 volt live and neutral supply, and controls a volt-free changeover switch, as well as an Open Therm® polarity-free output. Separate the receiver top cover from the base by gently lever-ing the cover upwards with a flat-bladed screwdriver placed into the two slots on the underside. Fit the receiver to the wall, and connect to the terminals provided. See the wiring diagrams below:
Before connecting the receiver to the boiler, make sure that you have followed the boiler external thermostat connection instructions. A mains connection to a volt-free terminal could damage the boiler circuitry.
Connect 230V AC Live and Neutral to L & N Connect the volt-free boiler connecons (SW1 / SW2) to COM & N O (common and normally
Connect 230V AC Live and Neutral to L & N Fit a short link wire between L & COM Connect the (230V mains) switched live to N O
The VIBE receiver is a double-insulated Class II control without earth connection. Use a separate single screw ter-minal block if earth contnuity is required. Affer wiring clip the cover on top of the installed receiver: apply light pressure unTl the housing clicks into place.
Power-up the control set and complete the seting up procedure
Affer fiffng batteries to the transmiter; fiffng the receiver to the wall and installing wired connections appropri-ate for the heatng appliance, switch on the mains supply to the receiver. The green Power LED should be visible on the receiver. The green LED will flash 1 x per second. Now check the receiver response: keep the transmiter approximately 1 to 2 metres from the receiver, and touch the UP arrow to raise the SET temperature above the measured ROOM temperature. Within 2 or 3 seconds the demand symbol
The transmiter and receiver control set is pre-commissioned at the factory. Refreshing of the RF link is possible (see Refresh RF Link on page 4), but this should not be necessary. The transmiter and receiver should communi-cate as soon as they are both powered-up. If there is a problem, make sure that:
Assuming the receiver response is O.K., proceed to the rest of the setting-up procedure.
Parameter setting — how to configure the way your Optimum Vibe thermostat works: S E T +
Option | Description | Range | Default value |
01 | Temperature calibration | -80C ~ +80C | 00C |
02 | Maximum temperature setting | 50C ~ 350C | 350C |
03 | Minimum temperature setting | 50C ~ 350C | 50C |
> 05 | Frost-protection temperature | OFF (- – in config. Screen), or 50C ~ 150C | 50C |
09 | Hysteresis (differential) | 0.50C ~ 3.50C | 0.50C |
> 11 | Child lock | 0: Unlock 1: Lock | 0 |
17 | Reset (reset all values to default) | Change to 1; touch Power button for 5 secs | 0 |
18 | Firmware code | Non adjustable * | 5091 |
19 | Firmware code | Non adjustable * | 0113 |
50 | Backlight | 0: OFF 1: AUTO | 1 |
> 52 | Temperature regulation mode | NOr: Normal (ON/OFF) OPs: Optimum Start tPi: Time Proportional / Integral | NOr |
> 53 | Time interval for Ops | 10 min, 15 min, 20 min | 20 min |
> 54 | Number of heating cycles/hour | Range: 2 ~ 3 ~ 6 ~ 12 | 6 |
> 55 | Proportional Bandwidth | Range: 1.50C— 30C | 20C |
See additional notes about these configuraition options on Page 4
Firmware is pre-loaded in the factory, and visible for reference but cannot be change
59 | Spare program space | ||
60 | |||
61 | Spare program space | ||
62 | Spare program space | ||
63 | Spare program space |
Configuration options—additional notes
Option | Description |
05 | If you set a frost-protection temperature, the heating will be switched on when the measured temper- ature falls below this level, even if the transmitter has been turned off. |
11 | When receiver connected via ON/OFF terminals, this setting can be adjusted via the transmitter or the App. |
52 | Please read ‘how it works’ for a full explanation of temperature regulation modes |
53 | Set if you chose OPs (Optimum Start) regulation. For the best results, the time interval selected should approximate the time taken to increase the room temperature by 1 degree. |
54 | Set if you chose TPi regulation. Select a lower number for heating systems with a slow response, and a higher number for heating systems with a fast response. |
55 | Set if you chose TPi regulation. Sets the temperature below the set-point at which TPi control will begin |
Press and hold the centre override button on the receiver until the Heating on LED flashes rapidly. Release the override button—the LED must smll be flashing. For WiFi LINK—see WiFi instructions.
RF LINK: Turn off the transmitier by touching the ON/OFF icon. The display will go blank. Now touch the SET icon for 5 seconds. A unique pre-set four-character code will show in the top let of the display. Release and then briefly touch the SET icon once more. The receiver LED will stop flashing and the RF link has been refreshed. Quit back to normal running mode by touching the ON/OFF icon.
Turn on the transmiter by touching the ON/OFF icon, to bring the VIBE back into service.
You can turn off the receiver. The receiver’s output will switch off, and it will stop responding to the transmiter. Transmiter ON/OFF
You can save battery power on the transmiter, by touching the ON/OFF icon. The transmiter is switched off and will stop sending control signals; the receiver will also switch OFF until you turn the transmitier back on.
868 MHz radio frequency control between transmiter and receiver, with 4 character hexadecimal coding giving 65,536 code combinations. Transmiter power 2 x AAA alkaline. Touch-screen keys. 70 x 40mm backlit LCD. Di-mensions 120 x 85 x 22.5mm. Dual RF and WiFi 2.4 GHz receiver: power 230V AC, volt-free changeover 10A (resistive) switching, ON/OFF & manual override buttons. Dimensions 85 x 85 x 25mm. Wall-fixing centres 60mm.
QR058 Prepared for TFC Group by: J. Todd Issue 2: August 2020
DOWNLOAD MANUALS:
Tfc Tower WFSTAT PROGRAMMABLE THERMOSTAT INSTALLATION INSTRUCTIONS
OTHER MANUALS:
Tfc Tower WFSTAT PROGRAMMABLE THERMOSTAT USER INSTRUCTIONS
Tfc Tower WFSTAT PROGRAMMABLE THERMOSTAT PRODUCT DATA SHEET
Tfc Tower WFSTAT PROGRAMMABLE THERMOSTAT Operating Guide
Tfc Tower WFSTAT PROGRAMMABLE THERMOSTAT INSTALLATION INSTRUCTIONS
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…