Compatible With
WARNING
Important Safety Information
It is your responsibility to ensure that this thermostat is safely installed according to all applicable codes and standards. tekmar® is not responsible for damages resulting from improper installation and/or maintenance.
Notice
Do not attempt to service the thermostat. There are no user serviceable parts inside the thermostat. Attempting to do so voids warranty.
Materials Required
Notice
Consider the following:
Removing the Thermostat Base
Mounting the Thermostat
To prevent the risk of personal injury and/or death, make sure power is not applied to the thermostat until it is fully installed and ready for final testing. All work must be done with power to the circuit being worked on turned off.
Please be aware local codes may require this thermostat to be installed or connected by an electrician.
Relay Power Jumpers
The thermostat includes three relay power jumper connectors located below the wiring hole.
The WiFi Thermostat 562 operates a one or two-stage furnace for heating and an air conditioner for cooling.
Mechanical
Electrical
Thermostat jumpers:
J1 = On
J2 = On
J3 = On
The WiFi Thermostat 562 operates a first stage radiant floor and a second stage furnace for heating, and an air conditioner for cooling.
Mechanical
Electrical
Thermostat jumpers:
The WiFi Thermostat 562 operates a first stage radiant floor and a second stage fan coil for heating, and an air conditioner for cooling.
Mechanical
Electrical
Thermostat jumpers:
The WiFi Thermostat 562 operates a first stage baseboard/radiator and a second stage fan coil for heating, and an air conditioner for cooling.
Mechanical
Legend
Electrical
Thermostat jumpers:
The heating setpoint can be set from 40 to 95°F (4.5 to 35°C). The Heat On symbol is shown on the display when the thermostat is heating. Heating for freeze protection is provided whenever the air or floor temperature falls below 40°F (4.5°C), regardless of operating mode.
Regular Heating
W1 relay is on when the air temperature falls 1.5°F (1°C) below the Heat To setting. When the temperature reaches the Heat To setting, the relay turns off. The W2 relay turns on based on settings selected in the Setup menu. W2 turns off when the air temperature is 0.5°F (0.25°C) below the Heat To setting.
Radiant Floor Heating
When Radiant Floor Heating is selected in the setup menu, the W1 relay operates using Pulse Width Modulation. This improves comfort for radiant systems with high mass floors.
Room Sensor and Averaging
The thermostat can measure room temperature between -46 to 212°F (-43 to 100°C). The room temperature can be measured using a combination of the built-in and auxiliary sensors.
Floor Sensor for Radiant Floor Heating
If a floor sensor is connected, floor minimum and maximum settings are available. For a combination of air and floor temperature control, leave the internal air sensor on in the setup menu. A floor minimum can be used to prevent a fast drop in temperature caused by receding solar exposure. This operation is recommended for areas heated by afternoon sun through large windows. When the sun sets, it can take a long time for the floors to get warm again. This may cause the room to cool off too much in the early evening. A floor minimum setting can help with this condition by maintaining a floor minimum temperature. Keep in mind the floor minimum temperature will override the air temperature, and if set too high, may overheat the room.
A floor maximum is recommended for rooms with hardwood floors. Setting floor minimum and maximum temperatures is a way of enhancing the comfort of the living space while protecting floor coverings. If there are more than one floor temperature sensors, the temperature is averaged.
Warm Weather Shut Down (WWSD)
The heating system can automatically shut off based upon the outdoor temperature and the WWSD setting. This provides a convenient way to shut off radiant floor heating.
Cooling Operation
The cooling setpoint can be set from 45 to 100°F (7.0 to 38.0°C). The Cool On symbol is shown on the display when the thermostat is cooling.
Cold Weather Shut Down (CWSD)
The cooling system can automatically shut off based upon the outdoor temperature and CWSD setting. This prevents unwanted cooling during the winter.
After 60 seconds of inactivity, the thermostat home screen displays only the time and the temperature.
Schedule
Display
Setting | Range | Default |
TEMPERATURE UNITS Select °F or °C. | °F or °C | °F |
ENERGY USE View the number of hours the heating or cooling has operated either daily or monthly. | 0 to 24 (daily) 0 to 744 (monthly) | 0 hours |
Setting | Range | Default |
BRIGHTNESS ACTIVE Select the brightness when touching the screen. | 30 to 100% | 100% |
BRIGHTNESS INACTIVE Select the brightness when not in use. | Off, 30 to 100% | 50% |
BACKGROUND Select the background color. | White, Blue, Black, Latte, Espresso | Blue |
LANGUAGE Select the language. | English, Español, Français | English |
SCREEN CLEAN Locks screen for 10 seconds to allow cleaning. | N/A | N/A |
Time
Setting | Range | Default |
TIME FORMAT Select the time format. | 12 or 24 hour | 12 hour |
TIME SOURCE If Internet is available, the time source can be either automatically or manually set. | Automatic, Manual | Auto |
TIME ZONE Select the local time zone. | Hawaii, Alaska, Pacific, Mountain, Central, Eastern, Atlantic Newfoundland | Eastern |
DAYLIGHT SAVING TIME Select the brightness when not in use. | Off, On | On |
Incorrectly setting the time and date manually may prevent the thermostat from communicating to the mobile app. Automatic time source is recommended when using an Internet connection.
Fan
Before using the WiFi features of this product, you must accept the Terms of Use, as amended from time to time and available at Watts.com/terms-of-use. If you do not accept these terms, this product can still be used without WiFi features.
The thermostat includes a step by step tutorial to setup the WiFi connection.
WiFi Connection Status
Press COG > WiFi > WiFi:On > CIRCLE-INFO to view the thermostat connection status.
Check Password
Power Off and On
Check Router & Firewall
Consult the router manual or Internet Service Provider (ISP) for assistance with router setup with these configurations:
Network Troubleshooting
Create a WiFi Hotspot
The Setup menu contains five sub-menus that determine how the thermostat operates.
Setup – Toolbox
Setting | Range | Default | ||||
ERRORDisplays any error messages. | N/A | N/A | ||||
ACCESS LEVELSelect between user and installer access levels. User access level restricts access in the Setup Menu. | User, Installer | Installer | ||||
STATUS The current status of warm weather shut down, cold weather shut down and each of the relays. | WWSD, CWSD, W1, W2, Y1, G1 | N/A | ||||
SOFTWARE VERSIONDisplay the software version. | J1255A | N/A | ||||
LOAD DEFAULTSAll settings are returned to factory defaults. | Yes, No | No | ||||
CALIBRATE TOUCHSCREENRecalibrate the screen after loading factory defaults. | N/A | N/A | ||||
Screen Page 1 | ||||||
HEAT TO AWAYSelect the heating temperature when away. | Off, 40 to 95°F Off, 4.5 to 35.0°C | Off | ||||
HEAT TO MIN LIMITSelect the minimum heating temperature limit. | Off, 40 to 95°F Off, 4.5 to 35.0°C | Off | ||||
HEAT TO MAX LIMITSelect the maximum heating temperature limit. | Off, 40 to 95°F Off, 4.5 to 35.0°C | Off | ||||
COOL TO AWAYSelect the cooling temperature when away. | Off, 45 to 100°F Off, 7.0 to 38.0°C | Off | ||||
COOL TO MIN LIMITSelect the minimum cooling temperature limit. | Off, 45 to 100°F Off, 7.0 to 38.0°C | Off | ||||
COOL TO MAX LIMITSelect the maximum cooling temperature limit. | Off, 45 to 100°F Off, 7.0 to 38.0°C | Off | ||||
Screen Page 2 | ||||||
WARM WEATHER SHUT DOWNSelect the outdoor temperature at which the heating is shut off. | Off, 40 to 95°F Off, 4.5 to 35.0°C | Off | ||||
COLD WEATHER SHUT DOWNSelect the outdoor temperature at which the cooling is shut off. | Off, 40 to 95°F Off, 4.5 to 35.0°C | Off | ||||
Screen Page 3 | ||||||
FLOOR MIN – WAKESelect the floor temperature while in the wake schedule. Applies when there is both a floor and an air sensor. | Off, 40 to 95°F Off, 4.5 to 35.0°C | Off | ||||
FLOOR MIN – LEAVESelect the floor temperature while in the leave schedule. Applies when there is both a floor and an air sensor. | Off, 40 to 95°F Off, 4.5 to 35.0°C | Off | ||||
FLOOR MIN – RETURNSelect the floor temperature while in the return schedule. Applies when there is both a floor and an air sensor. | Off, 40 to 95°F Off, 4.5 to 35.0°C | Off | ||||
FLOOR MIN – SLEEPSelect the floor temperature while in the sleep schedule. Applies when there is both a floor and an air sensor. | Off, 40 to 95°F Off, 4.5 to 35.0°C | Off | ||||
FLOOR MIN – AWAYSelect the floor temperature while in away. Applies when there is both a floor and an air sensor. | Off, 40 to 95°F Off, 4.5 to 35.0°C | Off | ||||
FLOOR MAXSelect the maximum floor temperature. This protects the floor covering from over heating. Applies when there is a floor sensor. | Off, 40 to 95°F Off, 4.5 to 35.0°C | Off | ||||
SENSOR 1Select the type of sensor connected to S1 and Com wiring terminals. | Off, Room, Floor | Off | ||||
SENSOR 2Select the type of sensor connected to S2 and Com wiring terminals. | Off, Room, Floor, Outdoor | Off | ||||
INTERNAL ROOM SENSORSelect if the internal room temperature sensor is on or off. Only available when Sensor 1 or 2 is set to read a room or floor sensor. | Off, On | On | ||||
ROOM OFFSETManual offset correction of the room temperature measurement. | Off,-5 to +5°F -3.0 to 3.0°C | Off |
Setup – Alerts
Setting | Range | Default |
ROOM HOT WARNINGSends an email notification if the room exceeds this temperature. | Off, 40 to 100°F Off, 4.5 to 38.0°C | Off |
ROOM COLD WARNINGSends an email notification if the room falls below this temperature. | Off, 40 to 100°F Off, 4.5 to 38.0°C | Off |
AIR FILTER CHANGESends an email notification to change the air filter when the fan exceeds this run time. | Off, 200 to 2000 hours | Off |
Setup – Relays
Setting | Range | Default |
EQUIPMENTSelect the number states of the heating and cooling equipment. | 1 Heat/1 Cool, 2 Heat/1 Cool | 1Heat/1 Cool |
RADIANT FLOOR HEATINGSelect if the first stage W1 heats a radiant floor. | No, Yes | No |
W2 DIFFERENTIALSelect when the second stage W2 heating turns on. Turn on point is the heat to minus the differential. | 2 to 10°F1.0 to 5.5°C | 2°F1.0°C |
W2 DELAYSelect the time delay when the second stage W2 heating turns on. The time starts counting after the W1 relay is turned on. | 0 to 180 minutes | 1 minute |
Y MIN RUN TIMESelect the minimum time the cooling compressor must run before shutting off. This helps prevent compressor failure. | 0:30 to 10:00 minutes | 2:00 minutes |
Y MIN OFF TIMESelect the minimum time the cooling compressor must be off before turning back on. This helps prevent compressor failure. | 0:30 to 10:00 minutes | 5:00 minutes |
Screen Page 2 | ||
FAN RELAY Select which relays require fan operation. Combinations with W1 are not available when Radiant Floor Heating is set to yes. | G only, With YWith Y and W1, With Y and W2, With Y, W1 and W2 | G only |
HEAT-COOL TIME INTERLOCKWhen operating in Mode Auto, select the amount of time to wait between switching from heating to cooling and vice versa. | 10 to 180 minutes | 10 minutes |
When an error occurs an email notification will be sent to the registered tekmar Connect mobile or web app account owner.
Description |
MEMORY ERRORThe thermostat memory settings are corrupted. To clear, load the factory defaults in the Toolbox menu. The thermostat will not operate any heating or cooling equipment while this error message is present. |
INTERNAL ROOM SENSOR FAULTDue to an open or short circuit, the thermostat is unable to read the internal room temperature sensor. If sensor 1 or 2 is set to room the thermostat continues to operate, otherwise operation stops. The error cannot be field repaired. Contact your tekmar sales representative for warranty or repair procedures. |
SENSOR 1 FAULTDue to an open or short circuit, the thermostat is unable to read the sensor wired to S1 and Com. The thermostat stops normal operation if sensor 1 is the only active room or floor sensor or if a floor maximum temperature has been set. Check the auxiliary sensor wire for short circuits according to the sensor installa- tion manual. It may be necessary to replace the auxiliary sensor. Once the error has been corrected, the error message automatically clears. |
SENSOR 2 FAULTDue to an open or short circuit, the thermostat is unable to read the sensor wired to S2 and Com. The thermostat stops normal operation if sensor 2 is the only active room or floor sensor or if a floor maximum temperature has been set. Check the auxiliary sensor wire for short circuits according to the sensor installa- tion manual. It may be necessary to replace the auxiliary sensor. Once the error has been corrected, the error message automatically clears. |
ROOM HOT WARNINGThe room temperature is above the Room Hot Warning setting in the Alerts menu. The warning will automatically clear once the room temperature falls below the setting. |
ROOM COLD WARNINGThe room temperature is below the Room Hot Warning setting in the Alerts menu. The warning will automatically clear once the room temperature falls below the setting. |
CHANGE AIR FILTERThe fan run time has exceeded the Change Air Filter setting in the Alerts menu. To ensure clean air it is recommended to replace the air filter on the heating and cooling equipment. While viewing the warning, press the Clear button to clear the warning and reset the fan run time counter. |
WiFi Thermostat 562 Two Stage Heat, One Stage Cool, Fan | |
Literature | 562_C, 562_D, 562_J, 562_U |
Control | Microprocessor control. This is not a safety (limit) control. |
Packaged weight | 0.7 lb. (300 g) |
Dimensions | 4-5/8″ H x 3″ W x 15/16″ D (118 x 76 x 24 mm) |
Enclosure | White PVC plastic, NEMA Type 1 |
Approvals | Meets Class B: ICES & FCC Part 15 |
Ambient conditions | Indoor use only, 32 to 122°F (0 to 50°C), RH ≤90% non- condensing |
Power supply | 15 to 30 V (ac/dc), 2 VA standby, Class 2 |
Relays | 30 V (ac/dc), 2 A, Class 2 circuits |
Sensor | NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892 |
– Included | None |
– Optional | tekmar type # 070, 072, 073, 076, 077, 079, 084 |
Communications | WiFi 802.11n, 2.4 GHz, WPA2 encryption |
Mobile app | Apple iOS 12 or higher, Android 10 or higher |
Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product (“Product”), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same. The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s pass-through warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used in compliance with tekmar’s instructions, ordinary wear and tear excepted. The pass-through warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from the production date. The liability of tekmar under the Limited Warranty shall be limited to, at tekmar’s sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of contract.
The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period. This Limited Warranty does not cover the cost of the parts or labor to remove or trans-port the defective Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser’s agreement and warranty with its customers. Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product (“Product”), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same. The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s pass-through warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used in compliance with tekmar’s instructions, ordinary wear and tear excepted. The pass-through warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from the production date. The liability of tekmar under the Limited Warranty shall be limited to, at tekmar’s sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of contract. The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period.
This Limited Warranty does not cover the cost of the parts or labor to remove or transport the defective Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser’s agreement and warranty with its customers. Any representations or warranties about the Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser’s sole responsibility and obligation. Purchaser shall indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers. The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the Product was not installed in compliance with tekmar’s instructions and/or the local codes and ordinances; or if due to defective installation of the Product; or if the Product was not used in compliance with tek-mar’s instructions.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH THE GOV-ERNING LAW ALLOWS PARTIES TO CONTRACTU-ALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABILITY OR DESCRIPTION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VIOLATION OF ANY APPLICABLE ENVIRON-MENTAL, HEALTH OR SAFETY LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRACTUALLY EXCLUDED IS LIMITED SUCH THAT IT SHALL NOT EXTEND BEYOND TWEN-TY-FOUR (24) MONTHS FROM THE PRODUCTION DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED BY THE GOVERNING LAW.
Product Warranty Return Procedure All Products that are believed to have defects in workmanship or materials must be returned, together with a written description of the defect, to the tekmar Representative assigned to the territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar Representative, including an inquiry from Purchaser (if not a tekmar Representative) or Purchaser’s customers, regarding a potential warranty claim, tekmar’s sole obligation shall be to provide the address and other contact information regarding the appropriate Representative.
Need help? Go to our website or contact us.
DOWNLOAD MANUAL
tekmar IOM-T-562 WiFi Thermostat 562 Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…