Compatible With

  • 2-stage heating, 1-stage cooling and fan
  • Supports optional floor sensor for radiant floor heating applications

WARNING

  • Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure.
  • Keep this Manual for future reference.

Important Safety Information

It is your responsibility to ensure that this thermostat is safely installed according to all applicable codes and standards. tekmar® is not responsible for damages resulting from improper installation and/or maintenance.

  • This is a safety-alert symbol. The safety alert symbol is shown alone or used with a signal word (DANGER, WARNING, or CAUTION), a pictorial and/or a safety message to identify hazards.
  • When you see this symbol alone or with a signal word on your equipment or in this Manual, be alert to the potential for death or serious personal injury.
  • This pictorial alerts you to electricity, electrocution, and shock hazards.
  • This symbol identifies hazards which, if not avoided, could result in death or serious injury.
  • This symbol identifies hazards which, if not avoided, could result in minor or moderate injury.
  • This symbol identifies practices, actions, or failure to act which could result in property damage or damage to the equipment.
  • Read Manual and all product labels BEFORE using the equipment. Do not use unless you know the safe and proper operation of this equipment. Keep this Manual available for easy access by all users. Replacement Manuals are available at tekmarControls.com
  • It is the installer’s responsibility to ensure that this thermostat is safely installed ac-cording to all applicable codes and standards.
  • Improper installation and operation of this thermostat could result in damage to the equipment and possibly even personal injury or death.
  • This thermostat is not intended for use as a primary limit control. Other controls that are intended and certified as safety limits must be placed into the control circuit.

Notice
Do not attempt to service the thermostat. There are no user serviceable parts inside the thermostat. Attempting to do so voids warranty.

Tools Required

  • tekmar or jeweler screwdriver
  • Phillips head screwdriver
  • Wire stripper
  • Drill (for wall anchor)
  • 3/16″ drill bit (for wall anchor)

Materials Required

  • 18 AWG LVT Solid Wire (Low Voltage Connections)

Installation Location

 tekmar- IOM-T-562- WiFi- Thermostat -1

Notice
Consider the following:

  • Interior Wall.
  • Keep dry. Avoid potential leakage onto the control.
  • Relative Humidity less than 90%. Non-condensing environment.
  • No exposure to extreme temperatures beyond 32-122°F (0-50°C).
  • No draft, direct sun, or other cause for inaccurate temperature readings.
  • Away from equipment, appliances, or other sources of electrical interference.
  • Easy access for wiring, viewing, and adjusting the display screen.
  • Approximately 5 feet (1.5 m) off the finished floor.
  • The maximum length of wire is 500 feet (150 m).
  • Strip wire to 3/8″ (10 mm) for all terminal connections.
  • Use standard 8 conductor, 18 AWG wire.

Removing the Thermostat Base

 tekmar- IOM-T-562- WiFi- Thermostat -2 While holding the base section in one hand, pull the lower half of the display front towards you to pivot it away from the base.

Mounting the Thermostat

To prevent the risk of personal injury and/or death, make sure power is not applied to the thermostat until it is fully installed and ready for final testing. All work must be done with power to the circuit being worked on turned off.
Please be aware local codes may require this thermostat to be installed or connected by an electrician. tekmar- IOM-T-562- WiFi- Thermostat -3

Relay Power Jumpers

The thermostat includes three relay power jumper connectors located below the wiring hole. tekmar- IOM-T-562- WiFi- Thermostat -5

  • Set Jumper J1 to On to connect power R to the Rh1 terminal.
  • Set Jumper J2 to On to connect power R to the Rh2 wiring terminal.
  • Set Jumper J3 to On connects power R to the Rc wiring terminal.
  • Set the jumper to off to disconnect the power from Rh1, Rh2, or Rc respectively.

Application 562-1

The WiFi Thermostat 562 operates a one or two-stage furnace for heating and an air conditioner for cooling.

Mechanical

 tekmar- IOM-T-562- WiFi- Thermostat -6

 tekmar- IOM-T-562- WiFi- Thermostat -7Legend

  • C1 = Air Conditioner
  • F1 = Furnace
  • T1 = WiFi Thermostat 562

Electrical

 tekmar- IOM-T-562- WiFi- Thermostat -8

Thermostat jumpers:
J1 = On
J2 = On
J3 = On

Application 562-2

The WiFi Thermostat 562 operates a first stage radiant floor and a second stage furnace for heating, and an air conditioner for cooling.

Mechanical

 tekmar- IOM-T-562- WiFi- Thermostat -9

 tekmar- IOM-T-562- WiFi- Thermostat -110Legend

  • B1 = Boiler
  • BP = Boiler Pump
  • C1 = Air Conditioner
  • F1 = Furnace
  • PS = System Pump
  • T1 = WiFi Thermostat 562
  • V1 = Zone Valve
  • S1 = Optional Floor Sensor 079
  • S2 = Optional Indoor Sensor 084 ZVC1 = Zone Valve Control 304V, 306V

Electrical

 tekmar- IOM-T-562- WiFi- Thermostat - 11

Thermostat jumpers:

  • J1 = On
  • J2 = Off
  • J3 = Off

Application 562-3

The WiFi Thermostat 562 operates a first stage radiant floor and a second stage fan coil for heating, and an air conditioner for cooling. tekmar- IOM-T-562- WiFi- Thermostat - 12

Mechanical

 tekmar- IOM-T-562- WiFi- Thermostat -13Legend

  • B1 = Boiler
  • BP = Boiler Pump
  • C1 = Air Conditioner
  • F1 = Fan Coil
  • PS = System Pump
  • S1 = Optional Floor Sensor 079
  • S2 = Optional Indoor Sensor 084
  • T1 = WiFi Thermostat 562
  • V1 = Radiant Zone Valve
  • V2 = Fan Coil Zone Valve
  • ZVC1 = Zone Valve Control 304V, 306V

Electrical

 tekmar- IOM-T-562- WiFi- Thermostat -14

Thermostat jumpers:

  • J1 = On
  • J2 = Off
  • J3 = Off

Application 562-4

The WiFi Thermostat 562 operates a first stage baseboard/radiator and a second stage fan coil for heating, and an air conditioner for cooling.

Mechanical

 tekmar- IOM-T-562- WiFi- Thermostat -15

Legend

  • B1 = Boiler
  • BP = Boiler Pump
  • C1 = Air Conditioner
  • F1 = Fan Coil
  • PS = System Pump
  • S1 = Optional Floor Sensor 079
  • S2 = Optional Indoor Sensor 084
  • T1 = WiFi Thermostat 562
  • V1 = Radiant Zone Valve
  • V2 = Fan Coil Zone Valve
  • ZVC1 = Zone Valve Control 304V, 306V

Electrical

 tekmar- IOM-T-562- WiFi- Thermostat -16

Thermostat jumpers:

  • J1 = On
  • J2 = Off
  • J3 = Off

Sequence of Operation

Heating Operation

The heating setpoint can be set from 40 to 95°F (4.5 to 35°C). The Heat On symbol is shown on the display when the thermostat is heating. Heating for freeze protection is provided whenever the air or floor temperature falls below 40°F (4.5°C), regardless of operating mode.

Regular Heating
W1 relay is on when the air temperature falls 1.5°F (1°C) below the Heat To setting. When the temperature reaches the Heat To setting, the relay turns off. The W2 relay turns on based on settings selected in the Setup menu. W2 turns off when the air temperature is 0.5°F (0.25°C) below the Heat To setting.

Radiant Floor Heating
When Radiant Floor Heating is selected in the setup menu, the W1 relay operates using Pulse Width Modulation. This improves comfort for radiant systems with high mass floors.

  • 100% on time at Heat To setting -1.5°F
  • 50% on time at Heat To setting
  • 0% on time at Heat To setting + 1.5°F

Room Sensor and Averaging
The thermostat can measure room temperature between -46 to 212°F (-43 to 100°C). The room temperature can be measured using a combination of the built-in and auxiliary sensors.

  • Built-in room sensor only
  • Built-in room sensor with auxiliary room sensor(s) (temperature is averaged)
  • Auxiliary room sensor only

Floor Sensor for Radiant Floor Heating
If a floor sensor is connected, floor minimum and maximum settings are available. For a combination of air and floor temperature control, leave the internal air sensor on in the setup menu. A floor minimum can be used to prevent a fast drop in temperature caused by receding solar exposure. This operation is recommended for areas heated by afternoon sun through large windows. When the sun sets, it can take a long time for the floors to get warm again. This may cause the room to cool off too much in the early evening. A floor minimum setting can help with this condition by maintaining a floor minimum temperature. Keep in mind the floor minimum temperature will override the air temperature, and if set too high, may overheat the room.
A floor maximum is recommended for rooms with hardwood floors. Setting floor minimum and maximum temperatures is a way of enhancing the comfort of the living space while protecting floor coverings. If there are more than one floor temperature sensors, the temperature is averaged.

Warm Weather Shut Down (WWSD)
The heating system can automatically shut off based upon the outdoor temperature and the WWSD setting. This provides a convenient way to shut off radiant floor heating.

Cooling Operation

The cooling setpoint can be set from 45 to 100°F (7.0 to 38.0°C). The Cool On symbol is shown on the display when the thermostat is cooling.

  • Cooling relay Y1 turns on at Cool To setting + 1.5°F (1°C)
  • Cooling relay Y1 turns off at Cool To setting

Cold Weather Shut Down (CWSD)
The cooling system can automatically shut off based upon the outdoor temperature and CWSD setting. This prevents unwanted cooling during the winter.

User Interface

After 60 seconds of inactivity, the thermostat home screen displays only the time and the temperature. tekmar- IOM-T-562- WiFi- Thermostat -17

User Settings

Away

 tekmar- IOM-T-562- WiFi- Thermostat - 18

Schedule

 tekmar- IOM-T-562- WiFi- Thermostat - 19

Display

Setting Range Default
TEMPERATURE UNITS Select °F or °C. °F or °C °F
ENERGY USE
View the number of hours the heating or cooling has operated either daily or monthly.
0 to 24 (daily) 0 to 744 (monthly) 0 hours

 tekmar- IOM-T-562- WiFi- Thermostat - 19

Setting Range Default
BRIGHTNESS ACTIVE
Select the brightness when touching the screen.
30 to 100% 100%
BRIGHTNESS INACTIVE
Select the brightness when not in use.
Off, 30 to 100% 50%
BACKGROUND
Select the background color.
White, Blue, Black, Latte, Espresso Blue
LANGUAGE
Select the language.
English, Español, Français English
SCREEN CLEAN
Locks screen for 10 seconds to allow cleaning.
N/A N/A

Time

 tekmar- IOM-T-562- WiFi- Thermostat - 20

Setting Range Default
TIME FORMAT Select the time format. 12 or 24 hour 12 hour
TIME SOURCE If Internet is available, the time source can be either automatically or manually set. Automatic, Manual Auto
TIME ZONE Select the local time zone. Hawaii, Alaska, Pacific, Mountain, Central, Eastern, Atlantic Newfoundland Eastern
DAYLIGHT SAVING TIME Select the brightness when not in use. Off, On On

Incorrectly setting the time and date manually may prevent the thermostat from communicating to the mobile app. Automatic time source is recommended when using an Internet connection.

Fan

 tekmar- IOM-T-562- WiFi- Thermostat - 21

Before using the WiFi features of this product, you must accept the Terms of Use, as amended from time to time and available at Watts.com/terms-of-use. If you do not accept these terms, this product can still be used without WiFi features.
The thermostat includes a step by step tutorial to setup the WiFi connection.

  • Step 1
    Agree to Terms of Use
     tekmar- IOM-T-562- WiFi- Thermostat - 22
  • Step 2
    Turn on WiFi
     tekmar- IOM-T-562- WiFi- Thermostat - 24
  • Step 3
    Enter wireless network name. It must support WPA2 security encryption.
     tekmar- IOM-T-562- WiFi- Thermostat - 25
  • Step 4
    Enter WiFi password.
     tekmar- IOM-T-562- WiFi- Thermostat - 27
  • Step 5
    Enter ZIP or postal code. This determines your location for weather information.
     tekmar- IOM-T-562- WiFi- Thermostat - 30
  • Step 6
    Select if the time is set automatically from the Internet or manually.

WiFi and Connectivity Troubleshooting

WiFi Connection Status
Press COG > WiFi > WiFi:On > CIRCLE-INFO to view the thermostat connection status. tekmar- IOM-T-562- WiFi- Thermostat - 31

  1. WiFi Signal Strength
    • The WiFi signal must measure between 0 and -69 dB to have a reliable connection to the Watts cloud.
    • A WiFi extender is recommended to be installed if the WiFi signal is between -70 to -100 dB.
  2. Internet Connected
    The WiFi information screen will show Internet Connected when the thermostat is connected to the router and there is a connection to the Internet.
  3. IoT Connected
    • The thermostat connection status will show IoT Connected when connected to the Watts Cloud and the thermostat is ready to be registered to the app.

Check Password

  • Double check that you are using the correct WiFi network and password.
  • The password is limited to 32 characters, and can include upper and lower case letters, numbers, special characters and spaces. A space counts as a character.
  • The thermostat supports WPA2-Personal password security.

Power Off and On

  • Power the thermostat off. Next, power the router off, wait 10 seconds, then power on and wait for the Internet status to be on. Then power the thermostat on.

Check Router & Firewall
Consult the router manual or Internet Service Provider (ISP) for assistance with router setup with these configurations:

  • The router must provide a 2.4 GHz signal. The thermostat is not compatible with 5 GHz networks.
  • The router is using WPA2-Personal security.
  • The router has DHCP enabled with enough available addresses for all Internet devices.
  • The router firewall is not blocking the outbound UDP or TCP ports: 53, 123, 443, 8883.
  • The router firewall is not blocking connections to *.azure-devices.net
  • The router firewall is not blocking the thermostat based upon a MAC filter list.

Network Troubleshooting

  • tekmar provides free access to a network troubleshooting tool called RouteThis Helps.
  • Download the app from the App Store or Google Play Store to your mobile device.
  • Enter code “TEKM” and click “Network scan”. The app will provide further instructions.

Create a WiFi Hotspot

  • If you are unable to connect to the WiFi network, try creating a WiFi Hotspot on your mobile device to bypass the router.
  • Apple* iOS WiFi hotspot instructions https://support.apple.com/en-us/HT204023
  • Android** WiFi hotspot instructions https://support.google.com/android/answer/9059108
  • If the thermostat displays IoT connected when using the WiFi Hotspot, please contact your Internet Service Provider (ISP) or IT professional for assistance with the router.

Setup

The Setup menu contains five sub-menus that determine how the thermostat operates. tekmar- IOM-T-562- WiFi- Thermostat - 31

Setup – Toolbox

Setting Range Default
ERRORDisplays any error messages. N/A N/A
ACCESS LEVELSelect between user and installer access levels. User access level restricts access in the Setup Menu. User, Installer Installer
STATUS

The current status of warm weather shut down, cold weather shut down and each of the relays.

WWSD, CWSD, W1, W2, Y1, G1  

N/A

SOFTWARE VERSIONDisplay the software version. J1255A N/A
LOAD DEFAULTSAll settings are returned to factory defaults. Yes, No No
CALIBRATE TOUCHSCREENRecalibrate the screen after loading factory defaults. N/A N/A
Screen Page 1
HEAT TO AWAYSelect the heating temperature when away. Off, 40 to 95°F Off, 4.5 to 35.0°C Off
HEAT TO MIN LIMITSelect the minimum heating temperature limit. Off, 40 to 95°F Off, 4.5 to 35.0°C Off
HEAT TO MAX LIMITSelect the maximum heating temperature limit. Off, 40 to 95°F Off, 4.5 to 35.0°C Off
COOL TO AWAYSelect the cooling temperature when away. Off, 45 to 100°F Off, 7.0 to 38.0°C Off
COOL TO MIN LIMITSelect the minimum cooling temperature limit. Off, 45 to 100°F Off, 7.0 to 38.0°C Off
COOL TO MAX LIMITSelect the maximum cooling temperature limit. Off, 45 to 100°F Off, 7.0 to 38.0°C Off
Screen Page 2
WARM WEATHER SHUT DOWNSelect the outdoor temperature at which the heating is shut off. Off, 40 to 95°F Off, 4.5 to 35.0°C Off
COLD WEATHER SHUT DOWNSelect the outdoor temperature at which the cooling is shut off. Off, 40 to 95°F Off, 4.5 to 35.0°C Off
Screen Page 3
FLOOR MIN – WAKESelect the floor temperature while in the wake schedule. Applies when there is both a floor and an air sensor. Off, 40 to 95°F Off, 4.5 to 35.0°C Off
FLOOR MIN – LEAVESelect the floor temperature while in the leave schedule. Applies when there is both a floor and an air sensor. Off, 40 to 95°F Off, 4.5 to 35.0°C Off
FLOOR MIN – RETURNSelect the floor temperature while in the return schedule. Applies when there is both a floor and an air sensor. Off, 40 to 95°F Off, 4.5 to 35.0°C Off
FLOOR MIN – SLEEPSelect the floor temperature while in the sleep schedule. Applies when there is both a floor and an air sensor. Off, 40 to 95°F Off, 4.5 to 35.0°C Off
FLOOR MIN – AWAYSelect the floor temperature while in away.

Applies when there is both a floor and an air sensor.

Off, 40 to 95°F Off, 4.5 to 35.0°C Off
FLOOR MAXSelect the maximum floor temperature. This protects the floor covering from over heating. Applies when there is a floor sensor. Off, 40 to 95°F Off, 4.5 to 35.0°C Off
SENSOR 1Select the type of sensor connected to S1 and Com wiring terminals. Off, Room, Floor Off
SENSOR 2Select the type of sensor connected to S2 and Com wiring terminals. Off, Room, Floor, Outdoor  

Off

INTERNAL ROOM SENSORSelect if the internal room temperature sensor is on or off. Only available when Sensor 1 or 2 is set to read a room or floor sensor. Off, On  

On

ROOM OFFSETManual offset correction of the room temperature measurement. Off,-5 to +5°F

-3.0 to 3.0°C

Off

Setup – Alerts

Setting Range Default
ROOM HOT WARNINGSends an email notification if the room exceeds this temperature. Off, 40 to 100°F Off, 4.5 to 38.0°C Off
ROOM COLD WARNINGSends an email notification if the room falls below this temperature. Off, 40 to 100°F Off, 4.5 to 38.0°C Off
AIR FILTER CHANGESends an email notification to change the air filter when the fan exceeds this run time. Off, 200 to

2000 hours

Off

Setup – Relays

Setting Range Default
EQUIPMENTSelect the number states of the heating and cooling equipment. 1  Heat/1 Cool,

2  Heat/1 Cool

1Heat/1 Cool
RADIANT FLOOR HEATINGSelect if the first stage W1 heats a radiant floor. No, Yes No
W2 DIFFERENTIALSelect when the second stage W2 heating turns on. Turn on point is the heat to minus the differential. 2 to 10°F1.0 to 5.5°C 2°F1.0°C
W2 DELAYSelect the time delay when the second stage W2 heating turns on. The time starts counting after the W1 relay is turned on. 0 to 180 minutes 1

minute

Y MIN RUN TIMESelect the minimum time the cooling compressor must run before shutting off. This helps prevent compressor failure. 0:30 to 10:00

minutes

2:00

minutes

Y MIN OFF TIMESelect the minimum time the cooling compressor must be off before turning back on. This helps prevent compressor failure. 0:30 to 10:00

minutes

5:00

minutes

Screen Page 2
FAN RELAY

Select which relays require fan operation. Combinations with W1 are not available when Radiant Floor Heating is set to yes.

G only, With YWith Y and W1, With Y and W2, With Y, W1 and W2  

G only

HEAT-COOL TIME INTERLOCKWhen operating in Mode Auto, select the amount of time to wait between switching from heating to cooling and vice versa. 10 to 180

minutes

10

minutes

Error Messages

When an error occurs an email notification will be sent to the registered tekmar Connect mobile or web app account owner.

Description
MEMORY ERRORThe thermostat memory settings are corrupted. To clear, load the factory defaults in the Toolbox menu. The thermostat will not operate any heating or cooling equipment while this error message is present.
INTERNAL ROOM SENSOR FAULTDue to an open or short circuit, the thermostat is unable to read the internal room temperature sensor. If sensor 1 or 2 is set to room the thermostat continues to operate, otherwise operation stops.

The error cannot be field repaired. Contact your tekmar sales representative for warranty or repair procedures.

SENSOR 1 FAULTDue to an open or short circuit, the thermostat is unable to read the sensor wired to S1 and Com. The thermostat stops normal operation if sensor 1 is the only active room or floor sensor or if a floor maximum temperature has been set.

Check the auxiliary sensor wire for short circuits according to the sensor installa- tion manual. It may be necessary to replace the auxiliary sensor. Once the error has been corrected, the error message automatically clears.

SENSOR 2 FAULTDue to an open or short circuit, the thermostat is unable to read the sensor wired to S2 and Com. The thermostat stops normal operation if sensor 2 is the only active room or floor sensor or if a floor maximum temperature has been set.

Check the auxiliary sensor wire for short circuits according to the sensor installa- tion manual. It may be necessary to replace the auxiliary sensor. Once the error has been corrected, the error message automatically clears.

ROOM HOT WARNINGThe room temperature is above the Room Hot Warning setting in the Alerts menu. The warning will automatically clear once the room temperature falls below the setting.
ROOM COLD WARNINGThe room temperature is below the Room Hot Warning setting in the Alerts menu. The warning will automatically clear once the room temperature falls below the setting.
CHANGE AIR FILTERThe fan run time has exceeded the Change Air Filter setting in the Alerts menu. To ensure clean air it is recommended to replace the air filter on the heating and cooling equipment. While viewing the warning, press the Clear button to clear the warning and reset the fan run time counter.

Technical Data

WiFi Thermostat 562 Two Stage Heat, One Stage Cool, Fan
Literature 562_C, 562_D, 562_J, 562_U
Control Microprocessor control. This is not a safety (limit) control.
Packaged weight 0.7 lb. (300 g)
Dimensions 4-5/8″ H x 3″ W x 15/16″ D (118 x 76 x 24 mm)
Enclosure White PVC plastic, NEMA Type 1
Approvals Meets Class B: ICES & FCC Part 15
Ambient conditions Indoor use only, 32 to 122°F (0 to 50°C), RH ≤90% non- condensing
Power supply 15 to 30 V (ac/dc), 2 VA standby, Class 2
Relays 30 V (ac/dc), 2 A, Class 2 circuits
Sensor NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892
– Included None
– Optional tekmar type # 070, 072, 073, 076, 077, 079, 084
Communications WiFi 802.11n, 2.4 GHz, WPA2 encryption
Mobile app Apple iOS 12 or higher, Android 10 or higher

Warranty

Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product (“Product”), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same. The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s pass-through warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used in compliance with tekmar’s instructions, ordinary wear and tear excepted. The pass-through warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from the production date. The liability of tekmar under the Limited Warranty shall be limited to, at tekmar’s sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of contract.

The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period. This Limited Warranty does not cover the cost of the parts or labor to remove or trans-port the defective Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser’s agreement and warranty with its customers. Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product (“Product”), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same. The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s pass-through warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used in compliance with tekmar’s instructions, ordinary wear and tear excepted. The pass-through warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from the production date. The liability of tekmar under the Limited Warranty shall be limited to, at tekmar’s sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of contract. The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period.

This Limited Warranty does not cover the cost of the parts or labor to remove or transport the defective Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser’s agreement and warranty with its customers. Any representations or warranties about the Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser’s sole responsibility and obligation. Purchaser shall indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers. The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the Product was not installed in compliance with tekmar’s instructions and/or the local codes and ordinances; or if due to defective installation of the Product; or if the Product was not used in compliance with tek-mar’s instructions.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH THE GOV-ERNING LAW ALLOWS PARTIES TO CONTRACTU-ALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABILITY OR DESCRIPTION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VIOLATION OF ANY APPLICABLE ENVIRON-MENTAL, HEALTH OR SAFETY LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRACTUALLY EXCLUDED IS LIMITED SUCH THAT IT SHALL NOT EXTEND BEYOND TWEN-TY-FOUR (24) MONTHS FROM THE PRODUCTION DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED BY THE GOVERNING LAW.

Product Warranty Return Procedure All Products that are believed to have defects in workmanship or materials must be returned, together with a written description of the defect, to the tekmar Representative assigned to the territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar Representative, including an inquiry from Purchaser (if not a tekmar Representative) or Purchaser’s customers, regarding a potential warranty claim, tekmar’s sole obligation shall be to provide the address and other contact information regarding the appropriate Representative.

Need help? Go to our website or contact us.

REFERENCE

DOWNLOAD MANUAL

tekmar IOM-T-562 WiFi Thermostat 562 Installation Guide

Tekmar-LOGO

tekmar IOM-T-562 WiFi Thermostat Installation Guide


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *