Switch | Position | Action |
1 | ON | LOCK Access level adjustment is not available. |
OFF | UNLOCK Access level adjustment is available. | |
2 | Not Used |
For tekmarNet®2 or 4 wiring, see Application Brochure 557_A or Installation & Operation Manual 557_D.
The following settings are essential to the successful operation of the system.
Setup Menu Settings |
SENSOR 1 Select the type of sensor connected to auxiliary sensor input 1. |
Range: OFF, ROOM, FLOR (floor), DUCT |
Default: OFF |
SENSOR 2 Select the type of sensor connected to auxiliary sensor input 2. |
Range: OFF, ROOM, FLOR (floor), OUT (outdoor) |
Default: OFF |
SENSOR 3 Select the type of sensor connected to auxiliary sensor input 3. |
Range: OFF, ROOM, FLOR (floor), HUM (humidity) |
Default: OFF |
ROOM SENSOR Select if the built-in room temperature sensor is on or off. |
Range: OFF or ON |
Default: ON |
W1 TERMINAL UNIT Select the terminal unit type of the first stage of heat W1. |
Range: NONE, HRF1, HRF2, OTHR (other) |
Default: NONE |
Setup Menu Settings |
BACKUP W2 TERMINAL UNIT Select the type of backup heating. |
Range: NONE, CONV, COIL, FURN (furnace), OTHR (other) |
Default: NONE |
Y1 RELAY Select the cooling equipment the Y1 relay operates. |
Range: HP1 (heat pump), AC1 (air conditioner), W2 |
Default: HP1 |
Y2 RELAY Select the equipment the Y2 relay operates. |
Range: OFF, HP2 (heat pump stage 2), AC2 (air condi- tioner stage 2), HRV, DHUM (dehumidifier), VALV (valve) |
Default: OFF |
ACCESSORY RELAY Select the equipment the accessory relay operates. |
Range: OFF, HUM (humidifier), DHUM (dehumidifier), VALV (valve) |
Default: OFF |
O/B VALVE Select the heat pump operation of the O / B relay. |
Range: O or B |
Default: O |
For a full list of settings and operational details, please refer to the thermostat Installation and Operation Manual (557_D) included with compatible tekmarNet® controls or download the brochure from www.tekmarControls.com
tekmar Control Systems Ltd., A Watts Water Technologies Company. Head Offi ce: 5100 Silver Star Road, Vernon, B.C. Canada V1B 3K4, 250-545-7749,
Fax. 250-545-0650
Web Site: www.tekmarControls.com
Product design, software and literature are Copyright ©2012 by tekmar Control Systems Ltd., A Watts Water Technologies Company
Download Manual: Tekmar 557 Thermostat Quick Setup Guide
another manual:Tekmar 557 Thermostat Installation & Operation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…