REV24.. – 7-day room temperature controller for the right temperature at the right time. All factory settings already provide optimal living comfort. You can easily adjust the controller to your needs with the user-assisted clear-text display and program selection slider.
Note the following for placing the controller:
Make sure no other influencing factors influence the controller’s temperature sensor (no solar radiation and other heat or cold source influences).
The controller display can show the following special symbols:
Is symbol
Is symbol
Caution: Time and date are retained for max. 1 minute. (All other settings are fixed and remain unchanged!)
Dispose of the batteries as per regulations.
Is symbol
The radio clock symbol only appears if the receiver is set up and activated to receive the time signal from Frankfurt (Germany). A permanent symbol indicates that both time and date of the controller are synchronized to Frankfurt (DCF77). The symbol flashes if the signal is not received for more than 1 week.
Is symbol
The controller is in “heating mode“
The controller contains a factory-set comfort switching pattern and temperature values. Proceed as follows for initial commissioning:
Remove the controller from the mounting base and pull off the black insulating tape from the 2 batteries: The controller turns on automatically. Reinsert the controller in the mounting base. | |
After startup, a welcome message appears for ca. 2 minutes. Press a button to interrupt the message. Language selection starts with “ENGLISH“ (factory setting). Press | |
Slider in position 1 (time setting): Press Note: You do not need to enter the time when DCF77 receiver for the time signal from Frankfurt (Germany) is equipped. | |
Slider in position 2 (date: day/month/year): Press Note:You do not need to enter the date when DCF77 receiver for the time signal from Frankfurt (Germany) is equipped. | |
RUN | Move the slider to the very right to position RUN (only way to close the cover). |
Set the operating mode with the operating mode selector. The factory setting is |
Fold the operating instructions and reinsert in the mounting base.
Turn on display lighting, check error messages or other important information
Change the temperature level in the time switch program, or are you not at home for a while?
Tips to save energy without reducing comfort
RED regulation
Siemens Switzerland Ltd. declares that the radio equipment type REV24.. is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at www.siemens.com/download?A6V10223314.
Select operating mode
Press the operating mode button
Operating modes with time program
Do you feel too warm / too cold?
Press
Note: To set your own programs, see: “Enter customized temperatures and switching times”.
Continuous operating modes
The controller offers continuous operating modes “Continuous comfort mode“
Slider in position 1 (time setting): Press | |
| Slider in position 2 (date: Day/month/year): Press |
RUN | Reset the slider to the RUN position. |
Note: You do not need to enter time and date when DCF77 receiver for the time signal from Frankfurt (Germany) is equipped. The time display shows PASS. |
Enter customized temperatures and switching times
The controller has three different switching patterns that you can allocate to the weekday blocks 1-5, the weekend block 6-7, or to the individual days 1…7.
Proceed as follows:
You can enter start, temperature and end of your holidays. The controller switches to the set holiday temperature at the start of the holidays and back to the preset operating mode at the end of the holidays.
During holiday mode, symbol
Proceed as follows:
Slider in position 15 (start of absence): Press | |
Slider in position 16 (temperature during absence): Press | |
Slider in position 17 (end of absence): Press | |
RUN | Move the slider back to RUN. Symbol |
Enter temperature for active remote control
With remote control, you are free to select the temperature. Activating remote control immediately enables control to the remote operating temperature regardless of the current operating mode. After you switch off remote control, the device returns to the set operating mode.
Symbol
Proceed as follows:
Slider in position 18 (temperature for active remote control): Press | |
RUN | Move the slider back to RUN. |
| Press The clocks starts at 12:00. Caution: All customized settings are lost ! |
Factory settings: Switching times | ||||||
Comfort phases | P1 | P2 | P3 | P4 | P5 | P6 |
1. | 07:00 | 23:00 | PASS | PASS | PASS | PASS |
2. | 06:00 | 08:00 | 17:00 | 22:00 | PASS | PASS |
3. | 06:00 | 08:00 | 11:00 | 13:00 | 17:00 | 22:00 |
You can activate Party mode only in operating modes
In Party mode, symbol
Proceed as follows:
DOWNLOAD MANUALS:
SIEMENS REV24 Room thermostat Operating Instruction
OTHER MANUALS:
SIEMENS REV24 Room thermostat Product Specifications Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…