Powerful. Versatile. Designed for light commercial HVAC systems applications. Ideally suited for schools, medical and financial offices, retail establishments, restaurants, and light manufacturing facilities. Now communicating on BACnet.
Hardware
General
| Part Number | Description |
| RDY2000BN | BACnet Commercial Thermostat |
| Part Number | Description |
| QAA2230.EWNN | Remote Wall Mounted Sensor – Temperature Only |
| QFA32SS.EWNN | Remote Wall Mounted Temperature and Humidity Sensor |
| QAM2030.010 | Duct Mounted Temperature Sensor |
| Part Number | Description |
| QFM2160U | Duct Mounted Temperature and Humidity Sensor |
| QPA2000 | Wall Mounted CO2 Sensor |
| QPA2062 | Wall Mounted Temperature + Humidity + CO2 Sensor |
| QPM2162 | Duct Mounted Temperature + Humidity + CO2 Sensor |
| QAC2030 | Outdoor Air Temperature Sensor |
| QAD2030 | Surface Mount Pipe Temperature Sensor |
| Topic | Title | Document ID: |
| Installation Instructions | RDY2000BN BACnet Enabled Commercial Room Thermostat | 125-1009 |
| Application Note | RDY2000BN BACnet Thermostat Heat Pump Application 14901 | 140-1230 |
| Application Note | RDY2000BN BACnet Thermostat Conventional Application 14900 | 140-1231 |
| WCIS Online Help | User’s Guide: Setup & Service Assistant (SSA) | N/A |
| Power supply | ||
| Operating voltage | 24 Vac ± 20%, Class 2, 4A maximum | |
| Frequency | 50/60 Hz. | |
| Power consumption including connected field devices | Max. 96 VA | |
| 24 Vac supply for field devices | ||
| Output relay ratings | Pilot duty, 1A maximum per output, 4A maximum total | |
| Ambient conditions and protection classification | ||
| Enclosure | NEMA 1 | |
| Transport | Temperature -13℉ through 158℉ (-25℃ through 70℃) Air humidity up to 95% (non-condensing) | |
| Operation | Temperature 23℉ through 122℉ (-5℃ through 50℃) Air humidity Up to 95% (non-condensing) | |
| Setpoint range | 45℉ through 95℉ (7℃ through 35℃) | |
| Standards, directives and approvals | ||
| UL | UL 916 | |
| cUL | CSA C22.2 No. 205 | |
| CE | EMC Directive | |
| ICES | Canada | |
| NOM-NYCE | Mexico | |
| Regulatory Compliance Mark | Australia | |
| Federal Communications Commission | Complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. | |
| BTL | BACnet Testing Laboratory | |
| Miscellaneous | ||
| Shipping weight | 14 ounces (0.4 kg) | |
Issued by
Siemens Industry, Inc. Building Technologies Division 1000 Deerfield Pkwy Buffalo Grove IL 60089
Tel. +1 847-215-1000
Siemens Industry, Inc., 2016
Technical specifications and availability are subject to change without notice.
Download Manual
Siemens RDY2000BN BACnet Enabled Commercial Room Thermostat User Guide
OTHER MANUAL
Siemens RDY2000BN BACnet Enabled Commercial Room Thermostat Installation Instructions
Siemens RDY2000BN BACnet Enabled Commercial Room Thermostat User Guide
Bad Ragaz Casino No Deposit Bonus Codes For Free Spins 2026 Details pertaining to the…
Online Slot Games For Money Playing online casinos UK on a mobile device Spin the…
Prime Fortune Casino No Deposit Bonus Codes For Free Spins 2026 Fantasy sports became a…
Online Casino Real Money Uk No Deposit Get ready to play the most realistic card…
Sin88 Casino No Deposit Bonus Codes For Free Spins 2026 This can be part of…
How To Always Win Blackjack Casino offer terms and conditions in UK Here is how…