Siemens RDY2000BN BACnet Enabled Commercial Room Thermostat User Guide

Siemens-LOGO

Siemens RDY2000BN BACnet Enabled Commercial Room Thermostat

Siemens-RDY2000BN-BACnet-Enabled-Commercial-Room-Thermostat-PRODUCT

Introduction

Powerful. Versatile. Designed for light commercial HVAC systems applications. Ideally suited for schools, medical and financial offices, retail establishments, restaurants, and light manufacturing facilities. Now communicating on BACnet.

  • BTL listed MS/TP ensures compatibility with any BACnet system.
  • Built-in flexible control programs for conventional and heat pump applications.
  • Controls conventional systems with up to 3 stages heating and 3 stages cooling.
  • Controls heat pumps with 1 or 2 compressors and up to 2-stage auxiliary heat.
  • On-board temperature and humidity sensor.
  • Multiple configurable inputs and outputs enable advanced control strategies.
  • Set-up Wizard enables rapid system configuration.
  • No special tools required for installation or commissioning.
  • Seven-day (2- or 4-event) occupancy scheduling.
  • Sleek design with backlit 5-inch LCD touchscreen.

Features

Hardware

  • Standard 24 Vac HVAC interface:
    • Y1, Y2, G, W1, W2 and O/B
  • Three selectable relay outputs
  • Four configurable inputs:*
    • Digital input
    • Resistive temperature input
    • 0 to 10V input
      *Requires purchase of external sensor(s). Control
  • BTL-listed BACnet MS/TP.
  • Fully-programmable 7-day, 2-, 4-, or 6-event occupancy scheduling function.
  • Real-time clock retains time and date for up to 48 hours upon loss of input power.
  • System configuration data is stored indefinitely upon loss of input power.
  • Interlocks and timers specifically designed for equipment protection.
  • Password protected installer set-up menu deters unauthorized changes.
  • Programmable fan enables fresh air circulation when not in heating/cooling mode.
  • Selectable lockout levels to minimize tampering with setpoints and schedule.
  • Programmable service reminders for humidifier pad, UV lamp, and air filter.

General

  • Separable back plate with wiring terminals and mounting holes configured to match most conduit box configurations (screws and anchors included for drywall mounting).
  • Thermostat secures to mounting base with screws to deter theft and vandalism.
  • Designed for horizontal layout.

Applications

  • Designed for light commercial HVAC systems with 24 Vac control circuitry.
  • Compatible with forced air, hydronic and steam systems fired by gas, oil or electricity.
  • Controls conventional systems with up to 3 stages heating and 3 stages cooling.
  • Controls heat pumps with 1 or 2 compressors and up to 2-stage auxiliary heat.
  • Built-in temperature and humidity sensor in addition to configurable inputs enables advanced room controls based on humidity, CO2, occupancy, remote or averaging temperature.
  • Selectable relays enable control strategies for humidity/dehumidity control, ventilation, economizer enable and occupancy notification.

Type summary

Part Number Description
RDY2000BN BACnet Commercial Thermostat

Accessories

Part Number Description
QAA2230.EWNN Remote Wall Mounted Sensor – Temperature Only
QFA32SS.EWNN Remote Wall Mounted Temperature and Humidity Sensor
QAM2030.010 Duct Mounted Temperature Sensor
Part Number Description
QFM2160U Duct Mounted Temperature and Humidity Sensor
QPA2000 Wall Mounted CO2 Sensor
QPA2062 Wall Mounted Temperature + Humidity + CO2 Sensor
QPM2162 Duct Mounted Temperature + Humidity + CO2 Sensor
QAC2030 Outdoor Air Temperature Sensor
QAD2030 Surface Mount Pipe Temperature Sensor

Product Documentation

Topic Title Document ID:
Installation Instructions RDY2000BN BACnet Enabled Commercial Room Thermostat 125-1009
Application Note RDY2000BN BACnet Thermostat Heat Pump Application 14901 140-1230
Application Note RDY2000BN BACnet Thermostat Conventional Application 14900 140-1231
WCIS Online Help User’s Guide: Setup & Service Assistant (SSA) N/A

Technical data

Power supply
Operating voltage 24 Vac ± 20%, Class 2, 4A maximum
Frequency 50/60 Hz.
Power consumption including connected field devices Max. 96 VA
24 Vac supply for field devices
Output relay ratings Pilot duty, 1A maximum per output, 4A maximum total
Ambient conditions and protection classification
Enclosure NEMA 1
Transport Temperature -13℉ through 158℉ (-25℃ through 70℃)

Air humidity up to 95% (non-condensing)

Operation Temperature 23℉ through 122℉ (-5℃ through 50℃) Air humidity Up to 95% (non-condensing)
Setpoint range 45℉ through 95℉ (7℃ through 35℃)
Standards, directives and approvals
UL UL 916
cUL CSA C22.2 No. 205
CE EMC Directive
ICES Canada
NOM-NYCE Mexico
Regulatory Compliance Mark Australia
Federal Communications Commission Complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.
BTL BACnet Testing Laboratory
Miscellaneous
Shipping weight 14 ounces (0.4 kg)

DimensionsSiemens-RDY2000BN-BACnet-Enabled-Commercial-Room-Thermostat-FIG.1

Issued by
Siemens Industry, Inc. Building Technologies Division 1000 Deerfield Pkwy Buffalo Grove IL 60089
Tel. +1 847-215-1000

Siemens Industry, Inc., 2016
Technical specifications and availability are subject to change without notice.

References:

Download Manual

Siemens RDY2000BN BACnet Enabled Commercial Room Thermostat User Guide

OTHER MANUAL

Siemens RDY2000BN BACnet Enabled Commercial Room Thermostat Installation Instructions

Siemens-LOGO

Siemens RDY2000BN BACnet Enabled Commercial Room Thermostat User Guide


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *