Secure

Secure SEC_SES301 Z-Wave thermostat Installational Instruction

Secure SEC_SES301 Z-Wave thermostat

Introduction

SES301 is a battery-powered temperature sensor that uses Z-Wave® technology low-power radio signals to transmit temperature data to a Controller.
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All constantly powered nodes within the network will act as repeaters for the SES301, which will help to increase network reliability.

Installation and commissioning 

  1. Install the two AAA batteries supplied with the unit, taking care to observe the polarity markings.
  2. To include the SES301 onto a network. Put the Controller in Include mode by pressing the button inside the unit for 2 seconds as shown in the diagram below. The Controller will show when the unit is linked.
  3. Choose the position where the unit is to be mounted. Avoid locations alongside or behind large metal surfaces that could interfere with the low-power radio signals between the unit and the Controller.
  4. The SES301 should be mounted on an internal wall, around 1.5 m above floor level and in a position away from draughts, direct heat and sunlight.
  5. Make sure that there will be sufficient space around the unit to allow easy access to the two retaining screws on the base of the wall plate.
  6. Fit the wall plate to the wall and then fit the SES301 on to the wall plate. Secure it in position by tightening the two captive screws.

If the unit needs to be excluded from a network, put the Controller in Exclusion mode and press the button on SES301 for more than 2 second. The Controller indicates when the process is completed.
The device classes supported are given below.

Z-Wave Device Classes Implemented Device Class
Generic Multilevel sensor
Specific Routing Multilevel sensor
Basic Routing Slave
Command Classes Supported Description
Manufacturer Specific Secure Manufacturer ID
Version Provides

software

the version number of the
Multilevel Sensor Supports Multilevel Sensor GET and Multilevel Sensor REPORT. The report carries the measured temperature as a 2- byte signed number (in °C or °F) with a precision of 1 decimal place. The report can be requested (or sent unsolicited) to the nodes in Group 1.
Battery Level Supports GET and REPORT, for battery level in the range 0-100%. Low Battery Warning is reported (with parameter = 0xFF) to the nodes in Group 2 if the battery voltage is less than 2.5 volts.
Wake Up(Ver 2) Wake Up Capabilities Report, supports wake up intervals in steps of 10s, with a default setting to 24 hrs, any received out of range wake up interval will be ignored.
Basic Mapped to the Multilevel Sensor Command Class as follows:

o  Basic SET: Not Supported

o  Basic GET: Multilevel Sensor Get

o  Basic REPORT: Multilevel Sensor Report

Association Two association groups are supported: Group 1 – Nodes to receive unsolicited multilevel sensor report.

Group 2 – Nodes to receive unsolicited low battery warnings report.

Each group contains a maximum of 4 nodes

Configuration Two single-byte configurations are supported for the temperature sensor functionality

1.  Configuration Parameter Number 1, temperature scale:

a.    0 to 127 (0x00-0x7F) = Celsius

b. – 1 2 8 t o – 1 ( 0 x 8 0 – 0 x F F )

= Fahrenheit

c.  Default value is 0

2.  Configuration Parameter Number 2, delta temperature:

a.    Can set in the range 1 to 100, in 0.1 degree steps

b.    Default value is 10 (1.0 ºC).

Note: To preserve battery life in a wider system, it is recommended that minimum default values are set for the following parameters:

Ÿ Wake up Interval: 15 Minutes (min)

Ÿ Temperature Report: Δ0.5°C (min) and/or Wake up (15 Mins)

Note: All command classes are version 1 unless otherwise stated.

Technical Information
Dimensions (WxHxD) 86 x 86 x 30 mm Power supply 2 x AAA alkaline cells
Measurement accuracy ±0.5 °C Transmitter frequency 868 Mhz
Pollution control degree 2 Design standard EN 60730-2-9
Enclosure protection Ip30 Operating range 0 °C to +40 °C
Enclosure material Flame-retardant thermoplastic

Cewe Instrument AB
Box 1006
611 31 Nyköping
Tel: +46 8 600 80 60
Email: info@securetogether.eu
Web Site: www.securetogether.eu

Reference

Download manual:

Secure SEC_SES301 Z-Wave thermostat Installational Instruction

Other Manual:

Secure SEC_SES301 Z-Wave thermostat User Manual

Secure SEC_SES301 Z-Wave thermostat Installational Instruction

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago