SAS816WHB-0-RF is a non-programmable thermostat, It is can replace the most common residential thermostats and designed to be used with electric, gas, water radiant, or oil heating control system or cooling system.
MOUNTINGANDWIRING DIAGRAM
MOUNTING THE RECEIVER
Mounting the Receiver onto the optional wall box (See Figure 4)
WIRING DIAGRAM
SWITCH AND LED DESCRIPTION OF RECEIVER
POWER SWITCH: When there is no demand to turn on the heating/cooling device, it is recommended to turn the power switch to the off position.
LED INDICATOR
The unit will be controlled via air sensor in the Control Centre and the Control Centre will determine whether to activate/deactivate the heating system by comparing the set temperature with room temperature. Press ▲ to adjust Control Centre setting above room temperature 1℃ in fast heating mode or 3℃ in slow heating mode, See configuration menu item 5. The Control Centre will emit signals to the Receiver asking to turn on the heating/cooling device. The yellow LED on the Receiver flashes means Receiver has received the signals. Green LED turns on means the heating/cooling device is energized. Press ▼ to adjust Control Centre setting below room temperature. The Control Centre will emit signals to the Receiver asking to turn off the heating/cooling device. The yellow LED on the Receiver flashes means Receiver has received the signals. Green LED turns off means the heating/cooling device is deactivated.
CONFIGURATION DIL SWITCH SETTINGS
Slide the DIL switches to the settings required (see Figure 2)
Both heating and Cooling selection
Compressor delay option for cooling selection
Display
The LCD displays the actual room temperature until the setting dial is moved.
Setting the temperature
Turn the setting dial to the required temperature. The selected temperature will flash in the LCD to signify it is showing the set temperature After a short period, the display stops flashing and shows the actual room temperature.
Thermostat status (heat mode only)
A flame symbol will be lit whenever the thermostat is calling for heat
Thermostat status (cool mode only)
A snowflake symbol will be lit whenever the thermostat is calling for cooling. If this is seen to flash, the thermostat output is delayed for a short period to prevent compressor damage.
Low battery indication
A battery symbol will flash in the display when batteries require replacement. Batteries should be replaced within 15 days, after which the thermostat will turn off the load it is controlling. When this happens “OF” will be displayed.
Switch function
The function of the switch at the lower side of the thermostat has 2 options. You can select the option by setting the second dip in the dip group. See DIL switch setting.
NSB setting
This switch is used as Day/Night switch. When the switch is set to the “Sun Symbol”, the thermostat controls at the temperature set by the setting dial. When set to the “Moon symbol”, the thermostat controls at 4℃ below the temperature set by the setting dial.
Note: if used to control cooling, the thermostat controls 4℃ higher, with a switch in the Moon position
ON/OFF setting
The switch is used as ON/OFF control When the switch is set to the “Sun Symbol”, the thermostat controls at the temperature set by the setting dial. When set to the “Moon symbol”, the thermostat output is turned off and “OF” is displayed.
CUSTOMER ASSISTANCE
After reading this guide, if you have any questions about the operation of your thermostat, please contact your installer or Energy Utility company or service provider
Download Manual:
Saswell SAS816WHB-0-RF2 Wireless Room Thermostat User Manual
Saswell SAS816WHB-0-RF2 Wireless Room Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…