Saswell SAS816WHB-0-RF2 Wireless Room Thermostat
SAS816WHB-0-RF is a non-programmable thermostat, It is can replace the most common residential thermostats and designed to be used with electric, gas, water radiant, or oil heating control system or cooling system.
SPECIFICATION
- Power source …………………… 3VDC
- Relay contact:……………………… 230VAC 10A
- Room temperature setting range………5℃ to 30℃
- Accuracy……………………………. ±1℃
- Dimensions………………………… 85mm X 84mm X32mm
- Color……………………………….. White
FEATURE
- LCD display shows room temperature
- Optional economic operation or comfort operation
- Optional temperature display of Celsius or Fahrenheit scale
MOUNTINGANDWIRING DIAGRAM
MOUNTING THE RECEIVER
Mounting the Receiver onto the optional wall box (See Figure 4)
- Remove assembly screws from the base of the thermostat. Gently pull the upper housing straight off the base. Forcing or prying on the thermostat will cause damage to the unit. See figure 1.
- Connect wires beneath terminal screws on the base using the appropriate wiring schematic. See figure 2
- Install two fresh “AA” alkaline batteries in the battery compartment. Be sure to match the positive (+) ends of batteries with positive (+) battery terminals in the battery compartment. See figure 3
- Push the power base into the wall.
- Using mounting screws mount the power base to the wall. Place a level against the bottom of the base, adjust until level, and then tighten the screws. (Leveling is for appearance only and will not affect
thermostat operation.) - Replace the upper housing on the base and fix the upper housing by removing the assembly screw
WIRING DIAGRAM
SWITCH AND LED DESCRIPTION OF RECEIVER
POWER SWITCH: When there is no demand to turn on the heating/cooling device, it is recommended to turn the power switch to the off position.
LED INDICATOR
- Red LED turns on as long as there is power to the unit
- Green LED turns on as long as the heating/cooling device is energized.
- Yellow LED flashes as long as there are any signals received from the Control Centre.
CHECK THERMOSTAT OPERATION
The unit will be controlled via air sensor in the Control Centre and the Control Centre will determine whether to activate/deactivate the heating system by comparing the set temperature with room temperature. Press ▲ to adjust Control Centre setting above room temperature 1℃ in fast heating mode or 3℃ in slow heating mode, See configuration menu item 5. The Control Centre will emit signals to the Receiver asking to turn on the heating/cooling device. The yellow LED on the Receiver flashes means Receiver has received the signals. Green LED turns on means the heating/cooling device is energized. Press ▼ to adjust Control Centre setting below room temperature. The Control Centre will emit signals to the Receiver asking to turn off the heating/cooling device. The yellow LED on the Receiver flashes means Receiver has received the signals. Green LED turns off means the heating/cooling device is deactivated.
CONFIGURATION DIL SWITCH SETTINGS
Slide the DIL switches to the settings required (see Figure 2)
Both heating and Cooling selection
- Select ℃ and ℉ readout
- Set the switch to ℃, the temperature in the display will be shown in ℃ readout.
- Set the switch to ℉, the temperature in the display will be shown in ℉ readout.
Switch function option
- ON/OFF – Switch at the lower side of the thermostat used as ON/OFF switch
- Setting the switch at, the thermostat is switched on.
- Setting the switch at the thermostat is switched off.
- NSB – Switch at the lower side of the thermostat used as NSB switch
- Setting the switch at, the thermostat is on comfort mode.
- Setting the switch at, the thermostat is on Night set back mode.
Compressor delay option for cooling selection
- Setting the Dil switch at NO DELAY, the compressor delay function is canceled.
- Setting the Dil switch at 5 MIN DELAY, the compressor will have 5 minutes of off-time protection.
Display
The LCD displays the actual room temperature until the setting dial is moved.
Setting the temperature
Turn the setting dial to the required temperature. The selected temperature will flash in the LCD to signify it is showing the set temperature After a short period, the display stops flashing and shows the actual room temperature.
Thermostat status (heat mode only)
A flame symbol will be lit whenever the thermostat is calling for heat
Thermostat status (cool mode only)
A snowflake symbol will be lit whenever the thermostat is calling for cooling. If this is seen to flash, the thermostat output is delayed for a short period to prevent compressor damage.
Low battery indication
A battery symbol will flash in the display when batteries require replacement. Batteries should be replaced within 15 days, after which the thermostat will turn off the load it is controlling. When this happens “OF” will be displayed.
Switch function
The function of the switch at the lower side of the thermostat has 2 options. You can select the option by setting the second dip in the dip group. See DIL switch setting.
NSB setting
This switch is used as Day/Night switch. When the switch is set to the “Sun Symbol”, the thermostat controls at the temperature set by the setting dial. When set to the “Moon symbol”, the thermostat controls at 4℃ below the temperature set by the setting dial.
Note: if used to control cooling, the thermostat controls 4℃ higher, with a switch in the Moon position
ON/OFF setting
The switch is used as ON/OFF control When the switch is set to the “Sun Symbol”, the thermostat controls at the temperature set by the setting dial. When set to the “Moon symbol”, the thermostat output is turned off and “OF” is displayed.
CUSTOMER ASSISTANCE
After reading this guide, if you have any questions about the operation of your thermostat, please contact your installer or Energy Utility company or service provider
Reference
Download Manual:
Saswell SAS816WHB-0-RF2 Wireless Room Thermostat User Manual
Saswell SAS816WHB-0-RF2 Wireless Room Thermostat User Manual
Leave a Reply