The RT520 and RT520RF are the latest additions to SALUS’ tried and tested RT range of thermostat heating controls. With a new on-board load compensation feature, they offer the most cost effective fully compliant Boiler Plus solution on the market providing the homeowner with optimum efficiency and maximum heating control comfort. Available in both wired and wireless RF versions, the new RT520 series include all the features of the previous RT series with a larger more intuitive LCD display and a handy new suite of additional operational and efficiency functions.
Before use please read this manual carefully.
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is available on www.saluslegal.com
868.0-868.6MHz; <13dBm
Safety Information
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU regulations.
Always ensure the AC mains power is switched off before installing or working on any components (this includes replacing the batteries). Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located in the back of the thermostat. Do not use rechargeable batteries.
RT520 Thermostat | RT520TX Thermo- stat (transmitter) | |
Thermostat supply | 2 x AA alkaline batteries | 2xAAalkalinebatteries |
Thermostat rating max | 3 (1) A | – |
OpenTherm terminals | A / B | – |
Outputs | Voltage free NC / NO / COM terminals | – |
Temperature range | 5°C – 33.5°C | 5°C – 33.5°C |
Temperature accuracy | 0.1°C OR 0.5°C | 0.1°C OR 0.5°C |
ErP control class | V | V |
Radio frequency | – | 868 MHz |
Dimension [mm] | 118 x 95 x 26 [mm] | 118 x 95 x 26 [mm] |
RXRT520 Receiver | |
Receiver supply | 230 V AC |
Receiver rating max | 16 (5) A |
OpenTherm terminals | A / B |
Outputs | Voltage free NO / COM terminals |
Radio frequency | 868 MHz |
Dimension [mm] | 96 x 96 x 26 [mm] |
Terminal | Description |
B / A | OpenTherm Communication Wire |
NC | Switched Live OFF |
NO | Switched Live ON |
COM | Common Terminal |
Terminal | Description |
B / A | OpenTherm Communication Wire |
NO | Switch Terminal |
COM | Common Switch Terminal |
L; N | Supply (230 V AC) |
RT520 Wiring Diagram
RT520TX Wiring Diagram
OpenTherm Power Up and Configuration
Please make the receiver connections and power the receiver before inserting the batteries into the thermostat.
TPI (Time Proportional & Integral) is a self-learning, time-proportional control algorithm. TPI type control ensures economical operation of the system thanks to more precise temperature maintenance during the control process. In addition to an accurate and stable room temperature, the advantage of this system is the minimization of energy consumption and significant savings. RT520 offers 3 types of TPI controls:
Hysteresis is the temperature difference between which the thermostat works, keeping the set temperature. For example, if you set the temperature to 20°C and if the hysteresis is ± 0.5°C, the heating will be turned on when the room temperature drops to 19.5°C and turned off when the temperature reaches 20.5°C.
When the OPTIMUM START function is active, the thermostat sends a heating signal to the heat source beforehand so that the preset temperature in the room is reached at the set time in the schedule.
When the OPTIMUM STOP function is active, the thermostat, taking into account the inertia of the system, switches off the heat source earlier, keeping the temperature set in the schedule.
Exemplary operation of the thermostat according to the schedule 6:00 – 23:00 21°C & 23:00 – 6:00 19°C:
TO SWITCH FROM AUTOMATIC TO MANUAL MODE:
TO SWITCH FROM MANUAL TO AUTOMATIC MODE:
Automatic Mode
The schedule has 6 time intervals for which different temperatures can be adjusted. You can set 2, 3 or up to 6 temperatures per day. You must define all time periods. Here is an example of setting a certain time with a certain temperature.
Note: Repeat the process for all time periods.
If you only need to change the set temperature twice a day, below is how to cancel one or more intervals.
TIME: | 6 TEMP/DAY | 2 TEMP/DAY |
06.00 | 21 °C | 21 °C |
10.00 | 14 °C | – |
12.00 | 21 °C | – |
14.00 | 14 °C | – |
18.00 | 21 °C | – |
21.00 | 14 °C | 14 °C |
Here are some examples of weekly schedules (for 6 and 2 temperature changes during the day).
Administrator settings is a function protected by a PIN code that allows the administrator to set a service reminder on the regulator that will warn the tenant about the upcoming boiler inspection.
If you are using the RT520RF pack, the pairing between the thermostat and the receiver is already done. During the pairing process, please make sure the thermostat and the receiver are at least 1 meter from each other.
If you bought the RT520TX and RXRT520 separately or if you want to re-pair thermostat with the receiver, make sure that the device is disconnected from the power supply and the switches on the receiver have been set to AUTO and ON. Then connect the receiver to the power supply and wait for the red LED to light steadily. Then switch to the OFF position and again to ON position quickly. The red flashing LED will confirm entering the pairing mode.
Test the Pairing Process
Note: Landlord settings will not be reset. Devices are still paired together.
Download Manual
SALUS RT520RF Wired Programmable Thermostat Quick Guide
OTHER MANUALS
SALUS RT520RF Wired Programmable Thermostat User Manual
SALUS RT520RF Wired Programmable Thermostat Wiring Diagram
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…