RT510 / RT510RF is a programmable room thermostat used to control room temperature. Device launching heating system by shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Extended features allows us to use various operating modes – automatic (time schedules), manual, frost protection or holiday. Before use please read this manual carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the cover. Do not use rechargeable batteries.
Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU.
Full information is available on the website www.saluslegal.com
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU regulations.
RT510 Thermostat | RT510TX Thermostat | |
Thermostat supply | 2 x AA alkaline batteries | 2 x AA alkaline batteries |
Thermostat rating max | 3 (1) A | – |
Outputs | Voltage free NO / COM / NC terminals | – |
Temperature range | 5 – 35°C | 5 – 35°C |
Temperature accuracy | 0.1°C or 0.5°C | 0.1°C or 0.5°C |
Control algorithm | TPI or hysteresis ±0.25°C | TPI or hysteresis ±0.25°C |
Radiofrequency | – | 868 MHz |
Dimension [mm] | 120x96x27 | 120x96x27 |
RXRT510 Receiver | |
Receiver supply | 230 V AC |
Receiver rating max | 16 (5) A |
Outputs | Voltage-free NO / COM terminals |
Radio frequency | 868 MHz |
Dimension [mm] | 96x96x27 |
Terminal | Description |
1 – COM | Common Terminal |
2 – NC | Switched Live OFF |
3 – NO | Switched Live ON |
Terminal | Description |
NO | Switch Terminal |
COM | Common Switch Terminal |
L, N | Supply (230 V AC) |
Control feature | TPI | Span |
Operation | When TPI is selected on | When Span is selec- |
DIP switch № 2, the DIP | ted on DIP switch № | |
switch № 1 is functional. | 2, the DIP switch № | |
You can choose the | 1 is not functional. | |
Cycles Per Hour between | The SPAN value is | |
a lower comfort level | set to ± 0.25°C – it is | |
(6CPH) and a higher | recommended to use | |
comfort level (9CPH). | with heating devices. |
In this mode, the user can set the schedules for the thermostat (temperature setpoints for specific periods of time). You have the option to choose between a 5-2 days program or a daily one by using the parameter d04 from Installer mode. Programmed schedules should use all time periods.
This function is available only in automatic mode (schedule). If a new setpoint temperature will be set during the schedule – it will be maintained until next time interval starts according to a programmed schedule
Temporary Override mode will be disabled when new schedule will be set.
In this mode thermostat does not work according to the programmed schedule but it will maintain selected temperature.
To turn off the Manual Mode press
This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature for a specified number of hours (up to 9 hours). Once that time is over, thermostat returns to previous mode.
temperature of the Frost Protection mode is set as default at 5°C. This temperature can be changed in Installer Mode in d03 parameter.
To turn off the Holiday Mode
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done
If you want to re-pair thermostat with the receiver, make sure that the device is disconnected from the power supply and the switches on the receiver have been set to AUTO and ON. Then connect the receiver to the power supply and wait for the red LED to light steadily. Next switch to the OFF position and again to ON position quickly. The red flashing LED will confirm entering the pairing mode.
Begin the pairing process
End the pairing process
Test the pairing process
If you purchased an RXRT510 or RT510TX and intend pairing with other devices in the 5×5 range, please refer to the Receiver Units manual or the relevant manuals available at www.salus-controls.eu
dxx | Function | Parametr | Default value |
d01 | Temperature display increments | 0.1°C or 0.5°C | 0.5°C |
d02 | Temperature offset | +/- 3.0°C | 0.0°C |
d03 | Frost Protection setpoint temperature | 5.0°C – 17.0°C | 5.0°C |
d04 | Programmer selection | 5/2 or 24 hr (7d) | 52 d |
Press the RESET button once. You can use a paper clip. Your thermostat will be reset and will start up automatically.
Remove the batteries without pressing any button. Wait 2 minutes and insert the batteries again. Your device will be restarted.
When you want to change the batteries your device will use the internal memory to backup your settings. You have 30 seconds to change the batteries before losing your settings.
SALUS CONTROLS DISTRIBUTOR:
QL CONTROLS Sp. z o.o., Sp. k.
ul. Rolna 4,
43-262 Kobielice,
Poland
Importer:
SALUS Controls Plc
Units 8-10 Northfield Business Park Forge Way, Parkgate
Rotherham
S60 1SD
United Kingdom
www.salus-controls.eu
SALUS Controls is a member of the Computime Group.
In accordance with the product development policy, SALUS Controls plc reserves the right to change specifications, design, and materials used in production, presented in this manual, without prior notice.
Download Manual
SALUS RT510TX Programmable thermostat Quick Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…