Please take a moment to try out your touch screen itself. To select a function on the touch screen, place your finger on the main temp display and give a short firm push. Try a “tap” of the finger or stylus. Your input must last long enough for the system to determine it is not an accidental ‘bump’. Using the stylus is more comfortable for some users. Again allow the system enough time to recognize your inputs. When you are comfortable with touch inputs, proceed.
Displayed when the MENU button is pressed from the HOME screen
Displayed when the PROGRAM button is pressed from the HOME screen
Auto-run
Press PROGRAM, from the HOME screen, to go to the program screen –
Select HEAT with the HEAT/COOL MODE switch
Select the PROGRAM (A or B) you want to set
Select the day you want to program
Touch the Day of the week area to cycle through the days of the week to select the desired day.
Select the time slot you want to program
Select the time of day (must be done in HEAT mode)
To COPY the program from the current day to another day
To program for cooling –
Select COOL with the Heat/Cool MODE switch and repeat the above procedure.
NOTE: Due to the requirements of AUTO mode, Time of Day will not be available in COOL programming, and all temperatures must be 3oF or more above the HEAT temp for that time slot. This avoids HEAT – COOL control conflicts over time or target temperature.
The 8030 has 3 manual override commands. These are accessed by touching the Current Temp Display at the HOME screen (center of the screen).
MANUAL override screen
HOLD
AWAY – Energy Efficient Pre-set –
Swing
Filter
Lock
12/24 hour
The thermostat can display time in 12 or 24-hour formats. At the HOME screen touch the time display to toggle from 12 to 24-hour display.
E.L. Backlight Backlight comes on automatically when the touch screen is touched or press the Backlight button for 16 sec of illumination.
DST Seting At the MENU screen, the DST toggles the clock on and off.
AUTO Switching
In the AUTO mode, the 8082C will automatically change from heat to cool as necessary. The AUTO uses the HEAT program for heating and the COOL program for cooling.
NOTE: If TEMPORARY or HOLD is used, the AUTO switching function is disabled.
Set Channel on Remote
To set the channel of the remote, slide the CHANNEL switch to your desired channel number.
Set Channel on the main unit
To set the channel of the main unit, press MENU and touch “CH” to select the same channel number as the remote and then touch “HOME”.
Temporary temperature override
To cancel the Remote temperature overrides –
Press the remote’s “RESET” button once. The main unit will return to its program.
Beep Pattern
The remote beeps once and then 3 seconds later beeps 1,2,or 3 times (depending on channel selection) and sends the signal. The thermostat beeps when it receives the signal.
Note: The unit sends a one-degree increment for each time you press the UP or DOWN arrow on the remote. Pressing the remote once per 3 second interval gives the unit time to respond to your command. Faster pressing can give unreliable results.
To Replace Batteries in the remote
Open the compartment as shown. Insert the A23 (MN21) size battery as shown and then replace the cover closed.
NOTE: The remote control system for the 8082c operates on external “C” wire power only. The thermostat must be connected to the “C” wire or a 24vac power source for the remote to function. If your unit is operating on Batteries only, then the remote function is disabled to protect battery life.
This device complies with Part 15 of the FCC Rules. Operation is subject to the follow two conditions: (1) This device may not casue harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user`s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inteference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, this is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
On the HOME screen, the humidity in the room is displayed. This thermostat can control the humidity level with the proper equipment installed in the HVAC system.
Maximum Humidity setting (Requires air conditioning and COOL mode)-This thermostat can be used to de-humidify by turning on the air conditioning as a function of humidity. Cooler air cannot hold as much moisture.
To set the MAX humidity level desired –
NOTE: The air conditioner will then be controlled by both humidity and/or temperature. Either one coming on will reduce the temperature and humidity.
Minimum Humidity setting (requires a built-in humidifier and HEAT mode)-This thermostat can be used to humidify by turning on a humidifier in the furnace. Connect the H terminal on the 8082C to the humidifier control relay. To set the MIN humidity level desired –
DOWNLOAD MANUALS:
Ritetemp 8082C programmable Thermostat Operaitional Manual
OTHER MANUALS:
Ritetemp 8082C programmable Thermostat Installational Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…