Before wiring and installing
Connect the heating mat to 1 & 2, connect the power supply to 3 & 4 and connect the floor probe to 5 & 6. If you connect it wrongly, there will be a short circuit and the thermostat may become damaged and the warranty will be invalid. You must always install the floor probe sensor. If you are installing the thermostat in a bathroom or wet room, then the thermostat needs to be placed outside the room and the floor probe needs to be inside. A lways check that the temperature limit for the floor probe is set to a suitable temperature for your flooring (typically 27℃). This can be done in the advanced setting menu A9 (see next page)
Always test the floor probe with a megger tester or fluke tester set to 2000 ohms, the reading should be between 8-15 ohms. The live and neutral are interchangeable.
Step 1: Setting up time and date
When you turn on the thermostat for the first time you will need to set the time and also the number that corresponds to the day of the week (1-7 starting from Monday). This can be done by following the steps below:
Step 2: Programming heating schedule
Days are divided into 6 periods. Wake up, sleep and 4 periods in between. When you are at home, set the period at a “comfort” temperature (typically 18C-21C). When you are out of the property or asleep, set the temperature of the period much lower (typically 15C-16C). This will help to reduce your energy costs.
To program the timings do the following:
Important:
Please note after about 10 seconds it will automatically save and exit.
Advanced options
When the thermostat is off hold
NO | Setting Options | Data Setting Function | Factory Default |
A1 | Show current temperature | Displays current temperature | N/A |
A2 | Temperature control return difference setting | 0.5-2.5℃ | 1℃ |
A3 | High-temperature protection temperature difference setting | 1-9°C | 2°C |
A4 | Sensor settings | N1: Air sensor only(do not use) N2:Floor probe only N3: Air sensor and Floor probe | N3 |
A5 | Child lock setting | 0:half lock 1:full lock | 0 |
A6 | High-temperature protection for external sensor | 20°C-70°C When setting temp = 20°C, , if press will display 【—】, cancel high temperature protection | 27°C |
A7 | Low-temperature protection | 1-10°C 1. When setting temp = 10℃, if press will display 【—】, cancel low temperature protection | 5°C |
A8 | Temperature minimum limit | 1-10°C | 5°C |
A9 | Temperature maximum limit | 20-70°C | 35°C |
AA | Descaling function | N/A for EUFH | N/A |
AB | Power with memory function | 0: Power with memory function 1: Shutdown power after power off 2: Shutdown power after power on | 0 |
AC | Weekly programming selection | 0: 5+2 1: 6+1 1. 2: 7 | 0 |
AD | Restore Factory Defaults | Hold OK button until all icons appear on screen | — |
Sensor fault display: Please choose the correct setting of the built-in and external sensor (option B1), if chosen incorrectly or if there is a sensor fault ( breakdown then errors E1 E2 or ER will be displayed on the screen. If this occurs ask the electrician to redo the test on the probe to ensure the cable was not damaged during the installation.
Warranty
We offer a warranty of 1 2 months, from the day of purchase. Beyond the warranty period, we will charge for the after-sale service.
Download manual:
Rayotec V2 Standard Touchscreen Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…