Raychem

Raychem NRG-DM Digital UNDERFLOOR HEATING THERMOSTAT Product Data Sheet

Raychem NRG-DM Digital UNDERFLOOR HEATING THERMOSTAT

DESCRIPTION

Digital timer thermostat for electrical underfloor heating equipped with a large display and intuitive software for optimal ease of use.

 

PRODUCT PROPERTIES

  • Intuitive wizard-based first time set-up of the thermostat
  • 2 pole main power switch for maintenance purposes
  • Clear big Dot Matrix LCD display (100 x 64 pixels) with blue backlight
  • Energy savings thanks to the adaptive function.
  • The thermostat calculates when it needs to start heating in order to reach the temperature at desired time of the weekly schedule.
  • Child lock to prevent accidental changes on the thermostat

Different display settings possible:

  • See the set temperature or the actual temperature on the screen
  • Show/hide time and date
  • Reverse background
  • Activate/deactivate the screen saver

Energy monitoring to visualize energy consumption over different periods of time Temperature calibration possible to adjust to the specific floor construction of the room Temperature scale to limit the thermostat to Min-Max temperatures in order to protect sensitive floors Supported Software languages: English, German, Dutch, French, Russian, Lithuanian, Polish, Czech, Swedish, Finish, Norwegian

TECHNICAL DATA

Supply voltage 230 VAC +/- 10%, 50Hz
Relay output Heating cable 230 V, max 13 A
Temperature range floor sensor 5°C to +40°C
Temperature range room sensor 5°C to +40°C
Limitation of range Low +5°C/High +40°C
Ambient temperature-operation 0°C to 25°C
Ambient temperature-transport -20°C to +70°C
Accuracy floor sensor 0.2°C in the range 0°C to +40°C
Accuracy room sensor 0.2°C in the range 0°C to +40°C
Temperature control method PID
Control modes Floor sensor Room sensor

Room sensor with floor limiter

No sensor

Clock function 1 to 6 events/day

7 days/week

1 temperature per event

Back-up for set values Non-volatile memory
Back-up for time and date Minimum 5 years of storage

Minimum 10 years if powered 50% of the time

Protection class IP21
Terminals 2,5 mm2 Screw cage clamp
Floor sensor 12k @ 25°C +/- 0.75°C (no:38165)
Max length of floor sensor 100 m, 2 x 1,5 mm² (230 VAC cable)
Diameter sensor cable 4.5 mm max. (preferred < 3.5 mm)
Diameter sensor tip 5.0 mm , +/-0.1 mm
Dimensions with frame 84 X 84 X 40 mm
Color Round front 9010
Color Square front 9003
Color switch gear frame 9010
Approvals CE, VDE

SYSTEM INFORMATION

  • Raychem underfloor heating thermsotats are used with
  • T2QuickNet mats 90 W/m² and 160 W/m²
  • T2Red – Self-regulating heating cable
  • T2Blue 10 W/m² and 20 W/m² heating cable
  • CeraPRO heating cable

COMPATIBILITY WITH LIGHT SWITCH GEAR FRAMES

An extra square front plate for compatibility with Schneider Exxact frames is provided as standard

Switch manufacturer Light switch product range
Busch-Jaeger Reflex SI, Reflex SI linear
Berker S.1, B.3
Eljo Trend
Ensto Jussi
Gira Standard 55, Event, E2, Esprit 55,
Merten Atelier, M1, 1-M, M-smart, M-ARC, M-Plan, M-Star
Jung A-500, A Creation, AS 500, A-Plus,
Elko RS16, Elko Plus
Clipsal S2000, ST2000
Schneider Exxact WDE 002501

WIRING DIAGRAM

  • Direct connection (single heating circuit)
  • Heater circuit < 13 Amps constant wattage cable or maximum 100 meter of T2Red
  • Connection via contactor (multiple heating circuits)
  • Total heating circuits > 13 Amps constant wattage cable or exceeding 100 meter of T2Red

ORDERING INFORMATION
R-NRG-DM 1244-015152

ACCESSORIES
Sensor-N 10K spare floor sensor* 1244-002952

if the spare sensor 1244-002952 is used, the sensor configuration needs to be set to NRG-Temp in the start-up wizard of the thermostat or in the Settings/Engineer settings/Sensor

Raychem

REFERENCE

DOWNLOAD MANUALS:

Raychem NRG-DM Digital UNDERFLOOR HEATING THERMOSTAT Product Data Sheet

Raychem NRG-DM Digital UNDERFLOOR HEATING THERMOSTAT Product Data Sheet

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago