Raychem-logo

Raychem NRG-DM Digital UNDERFLOOR HEATING THERMOSTAT

Raychem -NRG-DM- Digital -UNDERFLOOR -HEATING- THERMOSTAT- pro

DESCRIPTION

Digital timer thermostat for electrical underfloor heating equipped with a large display and intuitive software for optimal ease of use.

 

PRODUCT PROPERTIES

Different display settings possible:

Energy monitoring to visualize energy consumption over different periods of time Temperature calibration possible to adjust to the specific floor construction of the room Temperature scale to limit the thermostat to Min-Max temperatures in order to protect sensitive floors Supported Software languages: English, German, Dutch, French, Russian, Lithuanian, Polish, Czech, Swedish, Finish, Norwegian

TECHNICAL DATA

Supply voltage 230 VAC +/- 10%, 50Hz
Relay output Heating cable 230 V, max 13 A
Temperature range floor sensor 5°C to +40°C
Temperature range room sensor 5°C to +40°C
Limitation of range Low +5°C/High +40°C
Ambient temperature-operation 0°C to 25°C
Ambient temperature-transport -20°C to +70°C
Accuracy floor sensor 0.2°C in the range 0°C to +40°C
Accuracy room sensor 0.2°C in the range 0°C to +40°C
Temperature control method PID
Control modes Floor sensor Room sensor

Room sensor with floor limiter

No sensor

Clock function 1 to 6 events/day

7 days/week

1 temperature per event

Back-up for set values Non-volatile memory
Back-up for time and date Minimum 5 years of storage

Minimum 10 years if powered 50% of the time

Protection class IP21
Terminals 2,5 mm2 Screw cage clamp
Floor sensor 12k @ 25°C +/- 0.75°C (no:38165)
Max length of floor sensor 100 m, 2 x 1,5 mm² (230 VAC cable)
Diameter sensor cable 4.5 mm max. (preferred < 3.5 mm)
Diameter sensor tip 5.0 mm , +/-0.1 mm
Dimensions with frame 84 X 84 X 40 mm
Color Round front 9010
Color Square front 9003
Color switch gear frame 9010
Approvals CE, VDE

SYSTEM INFORMATION

COMPATIBILITY WITH LIGHT SWITCH GEAR FRAMES

An extra square front plate for compatibility with Schneider Exxact frames is provided as standard

Switch manufacturer Light switch product range
Busch-Jaeger Reflex SI, Reflex SI linear
Berker S.1, B.3
Eljo Trend
Ensto Jussi
Gira Standard 55, Event, E2, Esprit 55,
Merten Atelier, M1, 1-M, M-smart, M-ARC, M-Plan, M-Star
Jung A-500, A Creation, AS 500, A-Plus,
Elko RS16, Elko Plus
Clipsal S2000, ST2000
Schneider Exxact WDE 002501

WIRING DIAGRAM

Raychem -NRG-DM- Digital -UNDERFLOOR -HEATING- THERMOSTAT- 2

ORDERING INFORMATION
R-NRG-DM 1244-015152

ACCESSORIES
Sensor-N 10K spare floor sensor* 1244-002952

if the spare sensor 1244-002952 is used, the sensor configuration needs to be set to NRG-Temp in the start-up wizard of the thermostat or in the Settings/Engineer settings/Sensor

Raychem

REFERENCE

DOWNLOAD MANUALS:

Raychem NRG-DM Digital UNDERFLOOR HEATING THERMOSTAT Product Data Sheet

Raychem-logo

Raychem NRG-DM Digital UNDERFLOOR HEATING THERMOSTAT Product Data Sheet

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)