Warning: Turn off power to the heating or cooling equipment before installation.
Attention: For installation by experienced service technicians only.
Read all instructions before proceeding.
This thermostat requires 24 Volt AC Power or two (2) properly installed “AA” Alkaline batteries for proper operation. When connecting 24 Volt AC Power the batteries may be installed as a backup. Thermostat installation and all components of the system shall conform to Class II Circuits per NEC code.
For use only as described in this manual. Any other use will void the warranty.
This thermostat is compatible with:
Electrical and control specifications:
Terminations
Install your new PROSTAT thermostat in 4 basic steps:
Install the Sub-Base:
Provide Power
Wiring Terminations for model PRS6110
Terminal | Function | Description |
Rc | Input | 24 Volt AC Cooling Transformer (Dual Transformer Systems Only) |
Rh | Input | Power Connection (24 Volt AC Heating Transformer or Millivolt Power Source) |
G | Output | Fan Control |
W1 / E | Output | (W1) Conventional Heat Relay (E) Auxiliary/Emergency Heat |
O / B / V3 | Output | (O) Cool Active Reversing Valve (B) Heat Active Reversing Valve (V3) Zone Valve Power Close |
Y1 | Output | Compressor Relay |
C | Input | 24 Volt AC Transformer Common |
S1 | Input | Optional Remote Sensor (indoor or outdoor) |
S2 |
Wiring Terminations for model PRS6320
Terminal | Function | Description |
Rc | Input | 24 Volt AC Cooling Transformer (Dual Transformer Systems Only) |
Rh | Input | Power Connection (24 Volt AC Heating Transformer or Millivolt Power Source) |
G | Output | Fan Control |
W1 / E / W3 | Output | (W1) 1st Stage Conventional Heat, (E) Emergency Heat, (W3) 3rd Stage Auxiliary Heat |
W2 | Output | 2nd Stage Conventional Heat |
O / B / V3 | Output | (O) Cool Active Reversing Valve (B) Heat Active Reversing Valve (V3) Zone Valve Power Close |
Y1 | Output | 1st Stage Compressor |
Y2 | Output | 2nd Stage Compressor |
L | Input | System Malfunction Indicator |
C | Input | 24 Volt AC Transformer Common |
S1 | Input | Optional Remote Sensor (indoor or outdoor) |
S2 |
Typical Wiring Configurations
NOTE: The “System Type” option will be configured in the Installer Settings section. Shaded areas do not apply to PRS6110.
Heat Only or Millivolt
Set System Type to 11CONV
Rh | Power Connection [note 2] |
W1 | Heat Relay |
G | Fan Relay [note 4] |
C | 24 Volt AC Transformer Common [note 1, 3] |
Hydronic Heat Only
Set System Type to 1HD
Rh | 24 Volt AC Power (heating transformer) [note 2] |
W1 | Zone Valve Power Open |
V3 | Zone Valve Power Close |
G | Fan Relay [note 4] |
C | 24 Volt AC Transformer Common [note 1] |
Hydronic Heat / 1 Cool
Set System Type to 11HD
Rh | 24 Volt AC Power (heating transformer) [note 2] |
Rc | 24 Volt AC Power (cooling transformer) [note 2] |
W1 | Zone Valve Power Open |
V3 | Zone Valve Power Close |
Y1 | Compressor Relay |
G | Fan Relay (cooling fan only) |
C | 24 Volt AC Transformer Common [note 1, 3] |
1 HEAT / 1 COOL Single or Dual Transformer
Set System Type to 11CONV
Rh | 24 Volt AC Power (heating transformer) [note 2] |
Rc | 24 Volt AC Power (cooling transformer) [note 2] |
W1 | Heat Relay |
Y1 | Compressor Relay |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1, 3] |
2 HEAT / 2 COOL Single or Dual transformer
Set System Type to 22CONV (PRS6320 Only)
Rh | 24 Volt AC Power (heating transformer) [note 2] |
Rc | 24 Volt AC Power (cooling transformer) [note 2] |
W1 | Heat Relay Stage 1 |
W2 | Heat Relay Stage 2 |
Y1 | Compressor Relay Stage 1 |
Y2 | Compressor Relay Stage 2 [note 4] |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1, 3] |
NOTES – Conventional Systems
NOTE: The “System Type” option will be configured in the Installer Settings. Shaded areas do not apply to PRS6110.
1 HEAT / 1 COOL – No Auxiliary Heat
Set System Type to 11HP
Rh | 24 Volt AC Power |
Rc | Connected to Rh with supplied Jumper Wire |
O/B | Changeover Valve [note 2] |
Y1 | Compressor Relay |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1] |
2 HEAT / 1 COOL – Including Auxiliary Heat
Set System Type to 22HP (PRS6320 Only)
Rh | 24 Volt AC Power |
Rc | Connected to Rh with supplied Jumper Wire |
O/B | Changeover Valve [note 2] |
Y1 | Compressor Relay (1st stage heating/cooling) |
E | Auxiliary/Emergency Heat Relay [note 6] |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1] |
2 HEAT / 2 COOL – No Auxiliary Heat
Set System Type to 32HP (PRS6320 Only).
Rh | 24 Volt AC Power |
Rc | Connected to Rh with supplied Jumper Wire |
O/B | Changeover Valve [note 2] |
Y1 | Compressor Relay (1st stage heating/cooling) |
W2 | Auxiliary Heat Relay (2nd stage heating) [note 3] |
E | Emergency Heat Relay [note 3] |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1] |
L | Optional System Fault Monitor [note 4] |
3 HEAT / 2 COOL – Including Auxiliary Heat
Set System Type to 32HP (PRS6320 Only)
Rh | 24 Volt AC Power |
Rc | Connected to Rh with supplied Jumper Wire |
O/B | Changeover Valve [note 2] |
Y1 | Compressor 1 Relay (1st stage heating/cooling) |
Y2 | Compressor 2 Relay (2nd stage heating/cooling) |
E/W3 | Auxiliary Heat Relay (3rd stage heating) [note 5] |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1] |
L | Optional System Fault Monitor [note 4] |
NOTES – Heat Pump Systems
Additional Wiring Options
NOTE: Additional options are configured in the Installer Settings section.
S1 | Indoor or Outdoor Remote Sensor [note 1] |
S2 |
NOTE: Additional options are configured in the Installer Settings section.
NOTE: This thermostat ships configured as a 1H/1C conventional thermostat. Confirm installer settings.
Thermostat
* BACK and NEXT are secondary functions of the PROG and HOLD buttons. When in programming or configuration modes, BACK and NEXT appear in the display, indicating that the PROG and HOLD buttons now function as BACK and NEXT.
The Installer Settings must be properly configured in order for this thermostat to operate correctly. The Installer Settings are menu driven. The portion of these settings that do not apply to your setup will be skipped. These settings are indicated below with comments. More detail on each setting follows this table.
NOTE: Shaded areas below do not apply to the PRS6110.
No. | Installer Setting (Notes follow this table) | Factory Default | Setting Options | Comments (More information follows this table) |
1 | Residential or or Commercial Profile | RES | RES COMM | Select for Residential profile Select for Commercial profile |
2 | Programming Mode [note 1] | 7 PROG | 7 PROG 52 PROG NO PROG | Select for 7 day programming mode Select for 5-2 day programming mode Select for non-programmable mode |
3 | Clock Format | 12 HR | 12 HR 24 HR | Select for 12 hour clock Select for 24 hour clock |
4 | Temperature Scale | F DEG | F DEG C DEG | Select for Fahrenheit display Select for Celsius display |
5 | Auto Changeover | oF AUTO | oF AUTO ON AUTO | Disables Auto Changeover mode Enables Auto Changeover mode |
11CONV | Select for 1H/1C Conventional system | |||
22CONV | Select for 2H/2C Conventional system | |||
6 | System Type | 11CONV | 11HP 21 HP | Select for 1H/1C Heat Pump system Select for 2H/1C Heat Pump system (PRS6110) |
22HP 32HP | Select for 2H/2C Heat Pump system Select for 3H/2C Heat Pump system | |||
1HD 11HD | Select for Heat Only Hydronic system Select for Hydronic Heat/1C system |
No. | Installer Setting (Notes follow this table) | Factory Default | Setting Options | Comments (More information follows this table) |
7 | 1st Stage Differential | 0.5 DIF1 | 0.5, 1.0 or 2.0 DIF1 | Select a 1st stage temperature differential of .5°, 1° or 2° F (0.2°, 0.5° or 1.0° C) |
8 | 2nd Stage Differential [note 2] | 2.0 DIF2 | 1.0, 2.0, 3.0, 4.0, 5.0 or 6.0 DIF2 | Select a 2nd stage temperature differential of 1°, 2°, 3°, 4°, 5° or 6° F (0.5°, 1.0°, 1.5°, 2.0°, 2.5° or 3.0° C) |
9 | 3rd Stage Differential [note 2] | 2.0 DIF3 | 1.0, 2.0, 3.0, 4.0, 5.0 or 6.0 DIF3 | Select a 3rd stage temperature differential of 1°, 2°, 3°, 4°, 5° or 6° F (0.5°, 1.0°, 1.5°, 2.0°, 2.5° or 3.0°C) |
10 | 1st Stage Fan Control [note 3] | HG FAN 1 | HG FAN 1 HE FAN 1 | Select for 1st stage Gas heating Select for 1st stage Electric heating |
11 | Emergency Heat] Fan Control [note 4] | HE EMER | HE EMER HG EMER | Select for Electric Emergency Heat Select for Gas Emergency Heat |
12 | Reversing Valve (O/B Terminal) [note 5] | REVO | REVO REVB | Select for cool active Reversing Valve (O terminal) Select for heat active Reversing Valve (B terminal) |
13 | Fossil Fuel Backup Heat [note 4] | AE AUX | AE AUX AG AUX | Select for Electric Auxiliary heat (with compressor) Select for Gas Auxiliary heat (without compressor) |
14 | Compressor Power Outage Protection [notes 4, 6] | oF CPOP | oF CPOP on CPOP | Disables Power Outage Lockout Delay Enables Power Outage Lockout Delay |
15 | AC Power Interrupt Warning [note 6] | AC oF MONR | AC oF MONR AC on MONR | Disables AC Power Interrupt Warning Enables AC Power Interrupt Warning |
16 | Compressor Short Cycle Protection [note 7] | 5 CSCP | 5, 4, 3, 2 or 0 CSCP | Select a compressor short cycle protection delay of 5, 4, 3, 2 or 0 minutes |
17 | Residual Cooling Fan Delay [note 7] | 60 FAN | 90, 60, 30 or 0 FAN | Select a Residual Cooling Fan Delay of 90, 60, 30 or 0 seconds. |
18 | Circulating Fan Lock | oF CIRC | oF CIRC on CIRC | Disables Circulating Fan Lock mode Enables Circulating Fan Lock mode |
19 | Adaptive Recovery Mode (ARM™) [note 8] | oF REC | oF REC on REC | Disables Adaptive (early) Recovery mode Enables Adaptive (early) Recovery mode |
20 | Indoor Remote Sensor Control* [note 9] | I SENS | I SENS E SENS A SENS | Temperature is sensed from thermostat only. Temperature is sensed from remote sensor only. Temperature is combined with the thermostat and the remote sensor. |
21 | Lockout Security Level | 2 LOCK | 2 LOCK 1 LOCK | If locked – Complete lockout is enabled If locked – Partial lockout is enabled ( or is still functional) |
22 | Auto Changeover Dead Band [note 10] | 3 BAND | 2, 3, 4 or 5 BAND | Select a Dead Band of 2°, 3°, 4° or 5˚ F (1°, 2° or 3° C) for Auto Changeover mode. |
23 | Compressor Balance Point [notes 4, 11] | NO BALC | NO BALC | Disables Balance Points |
15-50 BALC | Select a Compressor Balance Point of 15°- 50°F (-9°-10° C) | |||
24 | Auxiliary Heat Balance Point [notes 4, 11] | NO BALA | NO BALA | Disables Balance Points |
70-40 BALA | Select a Auxiliary Heat Balance Point of 70°- 40° F (21°- 4° C) |
No. | Installer Setting (Notes follow this table) | Factory Default | Setting Options | Comments (More information follows this table) |
25 | Heat Set Point Upper Limit | 90LIM | 90-60 LIM | Select a Heat Set Point Upper Limit of 90°-60° F (32°-10° C) |
26 | Cool Set Point Lower Limit [note 7] | 45LIM | 45-80 LIM | Select a Cool Set Point Lower Limit of 45°-80° F (7°-27° C) |
*When an outdoor sensor is connected, the thermostat automatically recognizes it. Press PROG and HOLD at the same time to display outdoor temperature.
NOTE: Additional options such as Service Monitors, setting the lock code, etc. are located in the
User Settings – See User manual for information on setting these options.
Installer Manual 10
NOTES – Installer Settings
Detailed Explanation of Installer Settings (also see NOTES above):
Warning Read Before Testing
NOTE: The compressor delay can be bypassed by pressing the reset button on the front of the thermostat.
All user settings will be returned to factory default, however all Installer settings will remain as originally programmed in section 4.
PROPARTS warrants each new PROSTAT thermostat against any defects that are due to faulty material or workmanship.
This warranty and our liability do not apply to batteries, nor does it include damage to merchandise or the thermostat resulting from accident, alteration, neglect, misuse, improper installation or any other failure to follow PROSTAT installation and operating instructions. This limited warranty applies for the duration of the warranty period from the original date of purchase by a professional service technician.
PROPARTS agrees to repair or replace at its option any PROSTAT thermostat under warranty provided it is returned postage prepaid to our warranty facility in a padded carton within the warranty period, with proof of the original date of purchase and a brief description of the malfunction. This limited warranty does not include the cost of removal or re-installation.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province. Answers to any questions regarding our limited warranty may be obtained by writing our corporate offices.
For warranty service, please visit your nearest PROPARTS facility.
Technical Assistance: 855-445-2466 (U.S.)
Store this manual for future reference.
DOWNLOAD MANUALS:
Prostat PRS6110 Programmable Thermostats Installation Manual
OTHER MANUALS:
Prostat PRS6110 Programmable Thermostats Product Specifications Guide
Prostat PRS6110 Programmable Thermostats User Manual
Prostat PRS6110 Programmable Thermostats Installation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…