Pelican

Pelican TS250H Internet Programmable Thermostat Installation Guide

Pelican TS250H Internet Programmable Thermostat

Before Removing the Old Thermostat!

Note the wire colors and letter designations of the existing thermostat to assist in identifying the correct wiring connections to the TS250H.

Failure to follow these instructions can damage the product or cause a hazardous condition. Disconnect power during the installation of this product. All wiring must conform to local codes and ordinances. We strongly recommend that any installation or servicing be performed by a qualified technician. This thermostat is designed for use with 24VAC systems only. For additional support contact Pelican Technical Support at 888-512-0490 or email support@pelicanwireless.com

WARNING: NEVER INSTALL THE PELICAN THERMOSTAT ENCLOSED IN METAL. WIRELESS CANNOT COMMUNICATE THROUGH METAL.

Thermostat Terminal Designations

Conventional Control

Heat Pump Control

TS250H Mounting and Assembly

  1. Grasp front and back of thermostat and firmly pull apart.
  2. Mount thermostat rear cover to the wall.
  3. Align three pin connector from thermostat front cover to three pin connector on rear cover. Push front cover onto rear cover until secure.

Optional Tamper Resistant Lock

The thermostat contains an internal locking mechanism to secure the front cover to the rear cover. This is intended to keep untrained individuals from tampering with the power and thermostat wire. To engage the lock, assemble the thermostat and insert a 7/64″ Allen wrench (not included) into the key hole on the top of the thermostat. Rotate clockwise until reaching the stop to secure. Rotate counter-clockwise until reaching the stop to release.

Conventional Wiring Guide

5 Wire, 24VAC Conventional 1 stage cooling with 1 stage heat

Warning: For a Two Transformer System – remove jumper between R and Rc. Connect the 24VAC power for energizing the unit’s Compressor to thermostat’s (R) terminal. Connect second 24VAC power to thermostat’s (Rc) terminal.

6 Wire, 24VAC Conventional 1 stage cooling with 2 stage heat

7 Wire, 24VAC Conventional 2 stage cooling with 2 stage heat

7 Wire, 24VAC Conventional 1 stage cooling, 2 stage heat, and 2 fan speeds

5 Wire, 24VAC Heat Pump 1 stage cooling with 1 stage heat

6 Wire, 24VAC Heat Pump 2 stage cooling with 2 stage heat

6 Wire, 24VAC Heat Pump 2 stage cooling, 1 stage heat and auxiliary/emergency heat

7 Wire, 24VAC Heat Pump 2 stage cooling, 2 stage heat and auxiliary/emergency heat

7 Wire, 24VAC Heat Pump 1 stage cooling, auxiliary/emergency heat, and 2 stage fan

24VAC Humidification Output

24VAC Dehumidification Output

Optional Three Wire Installation

Some installations may have limited in-wall wire. In these cases, the TS250H can accommodate the use of only three wires and still provide control over the entire HVAC unit. To accomplish a three wire installation follow the steps outlined below:

  1. Loosen R and Rc terminal screws to remove jumper.
  2. Loosen R, C, and D terminal screws on the Wiring Module (WM700).
  3. Gently slide the WM700 to the right and remove module from the rear of the thermostat. The WM700 will slide out with very little force.
  4. Mount the WM700 inside the HVAC unit. Follow the Wiring Guide section of this installation guide for directions on how to wire the WM700 to your type of HVAC unit.
  5. Use the existing in-wall 18 gauge unshielded wire to connect the R, C, D terminals from the WM700 to the matching R, C, D terminals at the thermostat.

Thermostat Configuration

All configuration settings are made Online through the Pelican Web App. Each thermostat will automatically join the Pelican Web App and will be listed both as a notification and as a new thermostat under Admin. The thermostat is intially listed by it’s serial number. Most configurable items can be left at their default settings. For proper operation it is necessary to set the correct System Type (Conventional orHeat Pump). If the Web App is not accessable, the thermostat’s System Type can be set directly using the thermostat front keypad.

Setting System Type Using Thermostat Keypad

The thermostat can be placed into the correct system type (conventional or heat pump) during the first minute after the unit has been powered on. If the thermostat has been running for longer than one minute, remove the front cover of the thermostat from the rear base and then re-attach. This will cause it to recycle the power.

Within the first minute of the thermostat powered on, press and hold the up and down arrows simultaneously for five seconds. This will place the thermostat in configuration mode and the display will change to show one of the three possible system type settings:

Conventional System (Default)
Heat Pump

“W” Terminal Controls Reversing Valve. Energized for Cool.

Heat Pump

“W” Terminal Controls Reversing Valve. Energized for Heat.

The system type can be changed by pressing the up arrow on the thermostat. Once the correct setting is displayed, press any other button, the thermostat will save the setting and return to normal operation.

Pelican Wireless Systems.
All Rights Reserved.

For More Information on Pelican Wireless Systems

Please Visit: www.pelicanwireless.com

Contact

Reference

Download Manual:

Pelican TS250H Internet Programmable Thermostat Installation Guide

Other Manuals:

Pelican TS250H Wireless Thermostats Product Specification Guide

Pelican TS250H Internet Programmable Thermostat Installation Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago