General information
The original operating instructions were drafted in German. The operating instructions in other languages were translated from German.
Validity of the operating instructions
These operating instructions are valid for the surface-mounting room thermostat (heating and cooling) item number 1152064 and 1152065.
Type plate
The type plate is on the back of the device.
Extent of supply
Please check the delivery for any damages caused during transit and for completeness. The extent of supply described in these operating instructions includes:
Copyright and protective rights
These operating instructions are copyrighted. They are exclusively designed for persons involved with the product.
Declaration of conformity
Oventrop GmbH & Co. KG hereby declares that this product complies with the basic requirements and the other relevant provisions of the EU Directives concerned. The declaration of conformity can be obtained from the manufacturer.
Safety-related information
The constructional and commercial regulations must be observed during installation. The current standards, regulations and guidelines are valid.
Correct use
Foreseeable misuse
Constructive measures are not sufficient to exclude misuse.
The following must therefore be avoided:
Modifications to the product
Modifications to the product are not allowed. In case of modifications to the product, the warranty will become void. The manufacturer will not accept liability for damages and malfunctions caused by modifications to the product.
Warnings
DANGER
Indicates an imminent danger with high risk. It will lead to death or serious injury if the situation is not avoided.
WARNING
Indicates a possible danger with moderate risk. It may lead to death or serious injury if the situation is not avoided.
CAUTION
Indicates a possible danger with low risk. It may lead to minor and reversible injury if the situation is not avoided.
NOTICE
Indicates a situation which may lead to damage to property if not avoided.
Safety notes
This product is manufactured in accordance with the latest technical status and is fail-safe. Nevertheless, there might still be a residual danger for persons and property during installation and operation. The following safety notes must be observed.
Danger in case of inadequate personnel qualification
These operating instructions and all other valid documents (e.g. accessory manuals) have to be read, understood and applied by any person working on the product. Have all work on this product carried out by qualified tradesmen.
Electrician
The following work must only be carried out by a qualified electrician:
Due to professional training, knowledge and experience as well as knowledge of the relevant standards and regulations, the qualified electrician is in a position to carry out any work on electrical installations and connections. He has to recognize possible dangers.
Sanitary, heating and air-conditioning specialist
The following work must only be carried out by a qualified sanitary, heating and air-conditioning specialist:
Due to professional training, knowledge and experience as well as knowledge of the relevant standards and regulations, the sanitary, heating and air-conditioning specialist is in a position to carry out any work on heating and potable water installations. He has to recognize possible dangers.
User
The following work may be carried out by the user:
Operation of the device
The user has to be informed by the qualified tradesman as to the operation and must have read and applied the paragraph “Advice for the user”.
Danger to life due to electric current
Availability of the operating instructions
Construction
Functional description
The surface-mounting room thermostat serves the individual temperature control. It is designed for fan coil units with two- and four-pipe systems.
Functional description surface-mounting room thermostat for two-pipe systems (item no. 1152064)
The surface-mounting room thermostat for two-pipe systems features:
(see also: “Illustr. 5: Connection diagram 1152064“) With the help of an external sensor, the surface-mounting room thermostat for two-pipe systems detects whether the system is in heating and cooling operation. This information is shown on the display. Switching between heating and cooling has to be carried out manually.
Functional description of surface-mounting room
thermostat for four-pipe systems (item no. 1152065) The surface-mounting room thermostat for four-pipe systems features:
(see also: “Illustr. 6: Connection diagram 1152065“) With the help of an internal sensor, the surface-mounting room thermostat for four-pipe systems compares the actual and the nominal temperature and automatically switches between heating and cooling. The current operating mode is shown on the display.
Operating elements and display
Transport and storage
The product must be transported in the original packaging. The product must only be stored under the following conditions
General installation advice
The room thermostat should be installed at a location where a good circulation of air is guaranteed. If possible, the room thermostat should be mounted onto an inner wall at a height of 140 cm to 170 cm. Please make sure that the room thermostat is not affected by influenced by heat or cold sources (e.g. sunlight, cold outer walls). This is the only way to achieve a high measuring accuracy.
Wall attachment
Commissioning
Cable the room thermostat according to the respective connectiondiagram (see “Illustr. 5: Connection diagram 1152064“ and “Illustr.
Comfort and energy saving mode
Menu option | Factory settings | Control range | Function |
FC | °C | °C/°F | Select the required temperature unit. |
CL |
0 |
-4 up to +4 | The room thermostat is calibrated when leaving the factory. If the room thermostat cannot be positioned in such a way that the room temperature is measured without being influenced by external disturbance factors, the deviations can be compensated by modifying the settings. The value measured at a cold outer wall would, for instance, be lower than the actual room temperature. In this case, the value can be corrected upwards. The displayed temperature can be increased/decreased by up to +/- 4 °C/F compared to the measured temperature. |
CH | 35°C | 20°C to 35°C 68°F to 95°F | Select the maximum nominal value. During operation, this setting cannot be exceeded. |
CC | 5°C | 5°C to 20°C 41°F to 68°F | Select the minimum nominal value. During operation, this setting cannot be undercut. |
UC | 18°C | 10°C to 18°C 50°F to 64°F | Select the temperature for heating operation in night mode. |
UH | 25°C | 25°C to 30°C 77°F to 86°F | Select the temperature for cooling operation in night mode. |
PH | 1 | 1-10 | Select the height of the proportional band (P). |
LP | 5 | 0-10 | Select the height of the integral part (I). |
bL |
1 |
1/2/3 | Select between 3 types of lighting: • 1 = Lighting is switched on by pressing a switch • 2 = Permanent lighting • 3 = Lighting is permanently switched off |
HF |
h2 |
h1/h2/h3 | Select between 3 control options: • h1 = 0-10 V control for heating/cooling • h2 = 0-10 V control for heating/cooling + two point control for an additional heating • h3 = Two point control for an additional heating |
En | AC | OU/AC | Select the used temperature sensor: • OU = Return temperature sensor • AC = Room temperature sensor |
rC |
SC |
SC/OC/OO | Select the type of activation of the night mode via the key card function: • SC = Night mode with a closed electrical circuit • OC = <Night mode with an open electrical circuit • OO = Night mode is terminated |
OU | 2 | 1/2 | (only for item no. 1152065) • 1 = The room thermostat is working in the two-pipe system • 2 = The room thermostat is working in the four-pipe system |
Change analogue output signal
You can select between the analogue output signals 0-10 V or 0-20 mA. Position the jumper as follows to change the analogue output signal:
You can select between the analogue output signals 0-10 V or 0-20 mA. Position the jumper as follows to change the analogue output signal
Replacement of the fuse
The room thermostat is protected by a fuse which can be accessed after having removed of the operating device. Pull off the blue protection cap, take the fuse out of the holder and replace it.
Maintenance
The product is maintenance-free
Removal and disposal
Contact
DOWNLOAD MANUAL:
Oventrop 1152064 Room Thermostat Operating Instructions
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…