Olympia

Olympia BS-812-P PROGRAMMABLE THERMOSTAT User Manual

Olympia BS-812-P PROGRAMMABLE THERMOSTAT

Function

  • Backlight screen
  • Temperature setting 5.0 – 45.0°C with accuracy 0.1
  • Keypad lock.
  • Temperature measurement 0.0 – 99.9°C with accuracy 0.1
  • Anti-freeze protection to 4.5°C
  • 2 Alkaline batteries AA (LR06)
  • Lock temperature usage limits with PIN number
  • Boiler output*
  • Temperature sensor calibration ±3.0°C
  • Adjustable differential 0.2 – 1.5°C
  • Heating/Cooling function.
  • Temperature Unit (°C, °F)
  • Up to 20 weekly schedules
  • ECO mode

TECHNICAL CHARACTERISTICS

TECHNICAL CHARACTERISTICS
PRODUCT CODE BS-812/P

BS-812/P/C

BS-813/P

BS-813/P/C

BATTERIES 2 Alkaline ΑΑ (LR06)
FREE RELAY CONTACT 5Α – 250V AC 2 x 5Α – 250V AC
DEGREES OF COVER PROTECTION IP20
PRODUCED IN ACCORDANCE WITH EN 61000-6-1, EN 61000-6-3, EN 60730-1, EN 60730-2-9
OPERATION TEMPERATURE RANGE 5 to 45 oC
RELATIVE HUMIDITY 0 – 90% RH
EXTERNAL DIMENSIONS 120 x 31 x 80mm
CONSTRUCTION MATERIALS ABS/PC, PC
COLOR WHITE or ANTHRACITE (/C)
TYPICAL WEIGHT (including batteries) 180gr 190gr
WARRANTY                                                                                     2 years
DIMENSIONAL DRAWING (mm)

DIMENSIONAL DRAWING (mm)

THERMOSTAT MENU

MENU INFORMATION

To enter the menu, press and hold the key for 1 sec
Navigation/setting of the menu is done with the keys
Entering the individual menus and saving the settings is done by pressing the key 

To exit the menu press the ke

Hour
Set time and date.

ConF
In USEr mode (factory setting) you manually set the temperature by pressing the keys

In 7dAy mode you set the weekly schedules. To set the programs, follow the steps below:

  • In screen Add (P1), press the key to add the program.
  • Set the temperature by pressing the keys and press
  • Set the days according to figure 1.
  • Set the starting hour by press the keys and press
  • Set the stoping hour by press the keys and press
  • Next, you can add more programs or you can finish the setting by navigating to donE screen
  • Up to 20 programs can be set.
  • To delete the saved weekly schedules. Select the weekly schedule you want to delete, set the temperature to zero until the is displayed and press the key

Eco
Enabling this mode, the backlight of the screen remains off to save battery power.

Pin
Enabling the PIN, the temperature usage limits and the entry to the menu are locked. Enabling PIN does not restrict the use of the functions of the home screen. If the weekly schedule and PIN number are activated , it is not possible to set the usage limits, enable the night mode and enable the absent mode. In this case the PIN number only locks the menu entry. To disable the PIN, go to the menu PIN and select oFF. To change the PIN number you should disable the PIN number and set the PIN number from the start. In case you have forgotten the PIN number, a manual reset is possible

Adv

Advanced menu configuration

  • bot, Boiler operating time setting
  • Set the boiler operating time from 1-240 minutes. If the boiler time is 00, disable the boiler by pressing the key Factory settting is
  • n, ht , Night mode temperature setting.
  • The factory setting is 18.0oC.
  • Ab St, Absent mode temperature setting.
  • The factory setting is 14.0oC
  • CA LI , Calibration of the temperature sensor
  • The factory setting is 0.0oC and can be configured from -3.0 to +3.0oC.
  • diFF, Differential setting.
  • This setting defines the “temperature window” between enabling/disabling of the burner output. Factory setting is 0.2oC and can be configured from 0.2 to 1.5oC.
  • HECO, Operation mode of the thermostat (heating/cooling
  • For the heating mode: HEAt (factory default) and cooling: COLd.
  • Unit, Temperature display/measuring unit (Celsius degrees οC or Fahrenheit degrees oF)
  • rSt, Factory defaults settings
  • To reset the device press the key twice.

InFo

In this menu, the statistics recorded by the thermostat is displayed.

  • Burner operating hours.
  • Boiler operating hours.*
  • Maximum room temperature value
  • Minimum room temperature value
  • To reset the statistics, go to the screen Clr and press the key

Installation Instruction

Wall mounting

  • Wall mounting with recommended height: 1.5m from the floor on an internal wall.
  • Do not mount the devices in recesses, shelves, behind curtains or doors, or above or near heat sources.
  • Avoid direct exposure to sunlight

WARNING HEALTH AND SAFETY INFORMATION

  • Failure to comply with national safety regulations may result in personal injury, discomfort, property damage and other potential hazards
  • Comply with any national regulations and comply with appropriate safety regulations
  • You shall comply with any additional national regulatory informations

Risk of electric shock
Disconnect the power supply before any interference with the system

INFORMATION

GENERAL

  • Removing the plastic separator film between the two batteries, the thermostat is activated. The current room temperature is shown in the centre of the display.
  • Switch on the thermostat by pressing the key
  • Firstly, set the current time and day, by navigating to the menu Hour. Then, set the temperature by pressing the keys.
  • To enable the night mode press the key for 1 sec. The factory temperature setting is 18.0 OC and can be changed by navigating to the menu niht. This mode is disabled after 8 hours.
  • To enable the absent mode press the key for 1 sec. The factory temperature setting is 14.0 OC and can be changed by navigating to the menu AbSt.
  • To enable the boiler (BS-813/P & BS-813/P/C) press the key and the corresponding relay will command the boiler. The boiler will remain active as long as, it has been defined from the boti menu.
  • In case, that the value is the factory default, then the boiler can be disabled only by pressing the key
  • In case, the weekly schedule is enabled and change the temperature manually. The temperature remains the manual selection for 5 hours and after that the weekly schedule is been enabled again.

BATTERY REPLACEMENT
If the symbol appeared on the display, then the batteries must be replaced. Remove the front cover and replace the batteries with new one, same type and characteristics (2 alkaline batteries ΑΑ, 1.5V). Replace the front cover. Dispose the old batteries for recycling, in compliance with current environmental protection regulations.

ANTI-FREEZE PROTECTION
If the room temperature value is 4.5οC, then the thermostat will enable the burner, regardless of the thermostat status. This mode remains active, as long as the temperature is below 4.5οC.

THERMOSTAT KEYPAD LOCK 
To lock the thermostat press simultaneously the keys for 2 sec. To unlock press the same keys again.

KEYPAD DESCRIPTION

DISPLAY INDICATORS DESCRIPTION

WARRANTY

Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which accompanies each product. This warranty ceases to exist if the buyer does not follow the technical instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. Products that have been damaged can be returned to the premises of our company for repair or replacement, as long as the warranty period is valid. Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the transportation cost.

REFERENCE:

DOWNLOAD MANUALS:

Olympia BS-812-P PROGRAMMABLE THERMOSTAT User Manual

Olympia BS-812-P PROGRAMMABLE THERMOSTAT User Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago