Neomitis

Neomitis TMR7a DIGITAL ROOM THERMOSTAT INSTALLATION INSTRUCTIONS

Neomitis TMR7a DIGITAL ROOM THERMOSTAT

PACK CONTAINS

INSTALLATION

  • Unscrew the 2 screws under the timer.
  • Remove the wall plate from the timer.
  • Secure the wall plate with the two screws provided using the horizontal and vertical holes.
  • In case of surface mounting, a knock out area is provided on the wall plate and on the corresponding area of the timer.

WIRING

Internal wiring

  • N = Neutral IN
  • L = Live IN
  • 1 = Voltage free contact Feed IN 1
  • 2 = Voltage free contact Feed IN 2
  • 3 = Voltage free contact N.O. switching. out 1
  • 4 = Voltage free contact N.O. switching out 2

Note: for 230V switching, insert link between L and 2.

Wiring diagrams
Standard Connection to Combi Boiler (with Service shut-down if enabled of heating only)

Connection to Combi Boiler
(with Service shut-down if enabled of both heating & hot water)

MOUNTING OF THE TIMER

  • Replace the timer on the wall mounting plate.
  • Secure the timer by screwing both locking screws under the timer

INSTALLER SETTINGS

Access

  • Move the mode slider to off position.
  • Move the programming slider to position.
  • Press simultaneously and for 5 seconds.

5 advanced settings can be modified.
Press until correct option is in display then use or to select your choice.

Gravity/Pumped mode (1 – not used)

  • Press or to change to Gravity
    • 1 = Pumped
    • 2 = Gravity

  • Then save by moving the programming slider or save and go to next setting by pressing .

Set 12/24 hours clock 
The pre-set value is 12 hours clock.

  • Press or to change to “24h”.
  • Then save by moving the programming slider or save and go to next setting by pressing .

Auto Summer/Winter change over 
The auto Summer/Winter change over default is ON

  • Press or to change to OFF
  • Then save by moving the programming slider or save and go to next setting by pressing .

Set number of ON/OFF periods
You can adjust the number of ON/OFF switching time periods. The pre-set number is 2.

  • Press or to change to 3 periods
  • Then save by moving the programming slider or save and go to next setting by pressing .

Installation operating 
The digital timer can manage Central Heating or 1 zone. The pre-set choice is CH.

  • Press or to change to Z1.
  • Then save by moving the programming slider or save and go to next setting by pressing.

Backlight 
The backlight can be switched Off. The pre-set value is ON.

  • Press or to change to OFF
  • Then save by moving the programming slider or save and go to next setting by pressing .

TECHNICAL SPECIFICATIONS

  • Power supply: 220V-240V/50Hz.
  • Output per relay: 3(2)A, 12V-240V~.
  • Rated impulse voltage: 4000V.
  • Micro disconnection: Type 1B.
  • Pollution degree: 2.
  • Automatic action: 100,000 cycles.
  • Class II.

Environment

  • Operation temperature: 0°C to +40°C.
  • Storage temperature: from -20°C to +60°C.
  • Humidity: 80% at +25°C (without condensation)
  • Protection rating: IP30.

UKCA declaration of conformity: We, Neomitis Ltd, hereby declare under our sole responsibility that the products described in these instructions comply with statutory instruments 2016 No.1101 (Electrical Equipment safety Regulations), ), 2016 No.1091 (Electromagnetic Compatibility Regulations) , 2012 n°3032 (ROHS) and following designated standards:

  • 2016 No.1101 (Safety): EN 60730-1:2011, EN 60730-2-7:2010/ AC:2011, EN 60730-2-9:2010, EN 62311:2008
  • 2016 No.1091 (EMC): EN 60730-1:2011 / EN 60730-2-7:2010/AC:2011 / EN 60730-2- 9:2010
  • 2012 n°3032 (ROHS): EN IEC 63000:2018

Neomitis Ltd: 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED
KINGDOM – contactuk@neomitis.com

EU declaration of conformity: We, Imhotep Creation, hereby declare under our sole responsibility that the products described in these instructions comply with the provisions of Directives and harmonized standards listed below:

  • Article 3.1a (Safety): EN60730-1:2011/ EN60730-2-7:2010/EN60730-2-9: 2010/ EN62311:2008
  • Article 3.1b (EMC): EN60730-1:2011/ EN60730-2-7: 2010/ EN60730-2-9: 2010
  • Imhotep Creation: ZI Montplaisir – 258 Rue du champ de courses – 38780 Pont-Evêque –
  • France – contact@imhotepcreation.com
  • Neomitis Ltd and Imhotep Creation belong to Axenco Group.

The symbol affixed on the product indicates that you must dispose of it at the end of its useful life at a special recycling point, in accordance with European Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to the retailer from which you buy the replacement equipment. Thus, it is not ordinary household waste. Recycling products enables us to protect the environment and to use less natural resources.

REFERENCE:

DOWNLOAD MANUALS:

Neomitis TMR7a DIGITAL ROOM THERMOSTAT INSTALLATION INSTRUCTIONS

OTHER MANUALS:

Neomitis TMR7a DIGITAL ROOM THERMOSTAT OPERATING INSTRUCTIONS

Neomitis TMR7a DIGITAL ROOM THERMOSTAT INSTALLATION INSTRUCTIONS 

wpx_thermostats

Recent Posts

Bad Ragaz Casino No Deposit Bonus Codes For Free Spins 2026

Bad Ragaz Casino No Deposit Bonus Codes For Free Spins 2026 Details pertaining to the…

2 weeks ago

Online Slot Games For Money

Online Slot Games For Money Playing online casinos UK on a mobile device Spin the…

2 weeks ago

Prime Fortune Casino No Deposit Bonus Codes For Free Spins 2026

Prime Fortune Casino No Deposit Bonus Codes For Free Spins 2026 Fantasy sports became a…

2 weeks ago

Online Casino Real Money Uk No Deposit

Online Casino Real Money Uk No Deposit Get ready to play the most realistic card…

2 weeks ago

Sin88 Casino No Deposit Bonus Codes For Free Spins 2026

Sin88 Casino No Deposit Bonus Codes For Free Spins 2026 This can be part of…

2 weeks ago

How To Always Win Blackjack

How To Always Win Blackjack Casino offer terms and conditions in UK Here is how…

2 weeks ago