Neomitis RTE7SD PROGRAMMABLE ROOM THERMOSTAT Operation Instruction

Neomitis RTE7SD PROGRAMMABLE ROOM THERMOSTAT

Overview

Thank you for purchasing our RT7SD PLUS, 7 day programmable digital room thermostat.
It is by listening to your requirements we have created and designed our products to be easy to operate and install.
It is this ease of operation that is intended to make your life easier and help you save energy and money.

CONTROLS AND DISPLAY

Thermostat

Programming sliders sequences:
Time/dateDay to be programed Comfort period settingComfort temperature Eco temperature Run.

LCD Display

SETTINGS

INITIAL POWER UP

  1. Once the thermostat is connected, all symbols will be displayed on the LCD screen as shown for two seconds.
  2. After 2 seconds, the LCD will show: The ambient temperature (‘C) solid.

PLEASE READ BEFORE PROGRAMMING YOUR THERMOSTAT

OPTIMISATION EXPLAINED

WHAT IS OPTIMISATION-OPTIMUM START?
Historically, most UK heating systems waste vast amounts of energy by firing unnecessarily early for most of the year. Homeowners tend to set their boiler on times based on when they wake up by guessing what time they feel that their boiler should fire in order to reach the requested target temperature; for example turning the boiler on at 6am in order to have a warm room/ home by their wake up time at 7am.
Dual function optimisation, priority to comfort or energy savings, the choice is yours: Depending on various parameters: room inertia, ambient temperature, de- sired temperature, the thermostat calculates and optimises the programming for each heating period whether set to Comfort or Savings (Eco):

PLEASE READ BEFORE PROGRAMMING YOUR THERMOSTAT

In OPTI COMFORT mode, priority to comfort
In OPTI COMFORT mode, the thermostat’s inbuilt algorithm optimises in order to guarantee maximum comfort during the COMFORT programme.

The processor within the thermostat starts the boiler operation at the optimum time to achieve the setpoint temperature at the start of the occupancy
period.
In this mode, the priority is given to anticipating and maintaining the comfort temperature during periods of occupancy.
In OPTI ECO mode, priority to energy savings
In OPTI ECO mode, the thermostat’s inbuilt algorithm optimises in order to guarantee maximum energy savings throughout the ECO programme.

Instead of using a fixed start time, Optimum Start calculates how long the house will take to warm up depending on the temperature of the home, then fires the boiler automatically at the most efficient moment in order to reach your target temperature by your programmed time.

HOW DOES OPTIMUM START WORK?
Optimum Start works on a daily basis. You set the time that you want to be warm and Optimum Start will do the rest; for example – if you wake up at 7:30AM, then set your thermostat’s start time for 7:30AM. Optimum Start ensures that you are warm when you want to be (and not before), reducing wasted energy and saving money (up to 10% of energy costs).
To change the optimisation type, refer to the instillation instructions/ advanced installer settings.

PROGRAMMING

SET DATE AND CLOCK

  1. Move the Programming slider to position . The default year 2019 is flashing
    Turn the dial clockwise to increment the au year. Turn the dial counter-clockwise to decrement the year.
    Press Enter to confirm and go to next setting.
  2. The default month 01 is flashing.
    Turn the dial clockwise to increment the month. Turn the dial counter-clockwise to decrement the month.01 January; 02 = February; 03 = March;
    04 April; 05 = May; 06 = June; 07= July;
    08 August; 09 September; 10 October; 11 = November; 12 = December.
    Press Enter to confirm and go to next setting.
  3. The default day 01 and the corresponding day underlining are flashing.
    Turn the dial clockwise to increment the day. Turn the dial counter-clock- wise to decrement the day.
    Mo Monday; Tu = Tuesday; We= Wednesday; Th= Thursday; Fr =Friday; Sa = Saturday; Su = Sunday
  4. The default time 12.00 is flashing.
    To set the current time, turn the dial clockwise, to increment the time, turn the dial counter-clockwise, to decrement the time.

Note regarding the clock: The summer/winter change will be performed automatically
by the room thermostat.
To disable this feature, refer to the installation instructions/ advanced installer settings.

SET THE PROGRAM DAY

  1. Move the Programming slider to position Prog. The current day setting is flashing. The default day is Monday.

Option 1: Single day programming. Rotate dial to day required, eg Monday, press Enter. Underscore will become solid. Move the Program slider to any other position to confirm/finish this setting.

Option 2: Multiday programming. Select first day by pressing enter then turn the dial to right, to add additional days to be programmed and press
Enter to confirm each additional day. Move the Program slider to any other position to confirm/finish this setting.

SET THE PROGRAM COMFORT PERIOD

  1. To set the first Comfort start time, move the Programming slider to position .
    The default time is 6:30am.
  2. Turn the dial to set the time. Move the Program slider to the next position to confirm/finish this setting.
  3. To set the first Comfort end time, move the Programming slider to position
    The default time is 8:30am.
  4. Turn the dial to set the time. Move the Program slider to the next position to confirm/finish this setting.
  5. Repeat for the second comfort period JO, and for the third comfort period JOl.
    Comfort period Default times
    Comfort period 2 Start at 12:00 pm End at 02:00 pm
    Comfort period 3 Start at 0 :00 pm End at 10:00 pm

    Note: if you wish not to use a period then this can be done by Coinciding the End time with Start time.

TEMPERATURES SETTING

Two temperatures can be set: Comfort temperature and economy temperature

  1. To set the Comfort temperature, move the Programming slider to position. The default temperature is 20°C (68°F).
  2. Turn the dial to set the temperature between 5°C and 30°C, in increments of 0.5°C.
    Move the Program slider to the next position to confirm/finish this setting.
  3. To set the Economy temperature, move the Programming slider to position The default temperature is 16°C (61°F).
  4. Turn the dial to set the temperature between 5°C and 30°C, in increments of 0.5°C.
    Move the Program slider to the next position to confirm/finish this setting.
    NOTE: This is the temperature that the unit will work to outside of your comfort periods.
  5. Move the program mode slider to the Run position to confirm and finish all previous settings.

OPERATING

MODE SELECTION AND DESCRIPTION

Mode sliders sequences:
Auto mode Comfort mode Economy mode Standby.

Please select text to grab.

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago