For best performance, do not mount the receiver on metal wall boxes and leave at least 30 cm distance from any metal objects including wall boxes and boiler housing.
MOUNTING OF WALL MOUTING PLATE
The receiver is fixed on the wall with the standard wall plate which is supplied with the product.
WIRING
All electrical installation work should be carried out by a suitably qualified Electrician or another competent person. If you are not sure how to install this thermostat consult either with a qualified electrician or heating Engineer. Do not remove or refit the receiver onto the backplate without the main supply to the system being isolated. All wiring must be in accordance with IEE regulations. This product is for fixed wiring only.
Recommended locations for your thermostat.
To ensure that your thermostat provides accurate readings and controls effectively, it must be installed approximately 1.5 m above floor level on an inside wall, away from direct sunshine and any other sources of heat or cold such as radiators, cold draughts, etc.
• On the wall
On the table stand
The thermostat and the receiver are not bonded together at the factory. To bond the transmitter and the receiver together, proceed as below:
Note: the receiver is usually located near your boiler.
States of the indicator light | Operating states of the thermostat |
Green | Receiver is connected to the thermostat |
Orange | System is calling for heat |
Red | RF Signal has been lost, no connection between thermostat and receiver. In order to re-bond the thermostat and receiver refer to the installation instructions (page 2). |
Radio transmission is not working properly:
The radio link between the thermostat and the receiver is lost.
The thermostat does not control properly.
Receiver:
Maximum range in the home: 15m is typical but this varies depending on the building construction eg plasterboard lined with metal foil the number of walls and ceilings that the signal has to pass through and by the surrounding electromagnetic environment. Signal sending: every 10 minutes, maximum time-lag 1 minute after set-point temperature has been changed.
Environment
N.B: this room thermostat is one part of a complete radio system and will only work with the 230V AC receiver. Radio emitter, frequency from 2.40 to 2.48 GHz.
UKCA
UKCA declaration of conformity: We, Neomitis Ltd, hereby declare under our sole responsibility that the products described in these instructions comply with statutory instruments 2017 No. 1206 (Radio Equipment Regulations), 2012 n”3032 (ROHS) and following designated standards listed below:
EU declaration of conformity:
We, lmhotep Creation, hereby declare under our sole responsibility that the products described in these instructions comply with the provisions of Directives and harmonized standards listed below:
Electronic room thermostat that controls both the cycle time of the thermostat and the ratio between on and off periods during the same cycle of the heating device, depending on the room temperature. PID control reduces the average water temperature, improves the accuracy of room temperature control and increases system efficiency.
DISPOSAL
The symbol
Thank you for purchasing our RT0 RF, wireless digital room thermostat with PID and backlight. It is by listening to your requirements we have created and designed our products to be easy to operate and install. The thermostat is designed to make your life easier by helping you to save energy and money through ease of operation.
Thermostat
LCD Display
INSTALLING BATTERIES
1- Remove the batteries cover which is placed on the front of thermostat. | 2- Insert the 2 batteries AA supplied. Note the cor rect polarity according to the engraving on the thermostat when inser ting the batteries. | 3- Replace the batteries cover. |
PAIRING PROCEDURE
The thermostat and the receiver are not bonded together at the factory. To bond the transmitter and the receiver together, proceed as below:
TEMPERATURES SETTING
The desired temperature can be set. To set the temperature, turn the dial clo ckwise, to increase the temperature, turn the dial counter-clockwise, to decrease the temperature. The default temperature is 20°C (68F).
OPERATING STATES OF THE SYSTEM
States of the indicator light | Operating states of the thermostat |
Green | Receiver is connected to the thermostat |
Orange | System is calling for heat |
Red | RF Signal has been lost, no connection between thermostat and receiver. In order to re-bond the thermostat and receiver refer to the installation instructions |
OVERRIDE
You can press the OVERRIDE button on the receiver to manually switch ON/OFF if you have a faulty room unit or transmission signal. This will be operate until communication is restored.
Setting | Factory Setting |
Set temperature | 2O°c |
Note: To restore factory settings, press and hold down this part for more than 3 seconds using the tip of a pen.
All LCD display will be turned ON for 2 seconds and the factory settings will be restored.
TECHNICAL SPECIFICATIONS
Please refer to the installing instructions for any informations about batteries life, stan dards and product environment.
… an explanation for householders A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
Turning a room thermostat to a higher set ting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of boiler and radiators. Neither does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy.
The heating system will not work if a time switch or programmer has switched it off. The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature – say 182C – and then turn it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money. If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have different temperatures in indi vidual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs. Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or
table lamps may prevent the thermostat from working properly.
DOWNLOAD MANUAL
Neomitis RTE0RFB WIRELESS DIGITAL ROOM THERMOSTAT Installation Manual
OTHER MANUALS:
Neomitis RTE0RFB WIRELESS DIGITAL ROOM THERMOSTAT Installation Manual
Neomitis RTE0RFB WIRELESS DIGITAL ROOM THERMOSTAT Installation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…