Neomitis-logo

Neomitis RTE0RFB WIRELESS DIGITAL ROOM THERMOSTAT

Neomitis- RTE0RFB -WIRELESS -DIGITAL -ROOM- THERMOSTAT-PRO

PACK CONTAINS

Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-1

INSTALLATION – RECEIVER

For best performance, do not mount the receiver on metal wall boxes and leave at least 30 cm distance from any metal objects including wall boxes and boiler housing.

MOUNTING OF WALL MOUTING PLATE
The receiver is fixed on the wall with the standard wall plate which is supplied with the product.

  1. Unscrew the 2 screws under the receiver.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-2
  2. Remove the wall plate from the receiver.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-3
  3. Secure the wall plate with the two screws provided using the horizontal and vertical holes.Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-4
  4. In case of surface mounting, a knock out area is provided on the wall plate and on the corresponding area of the receiver.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-5

WIRING
All electrical installation work should be carried out by a suitably qualified Electrician or another competent person. If you are not sure how to install this thermostat consult either with a qualified electrician or heating Engineer. Do not remove or refit the receiver onto the backplate without the main supply to the system being isolated. All wiring must be in accordance with IEE regulations. This product is for fixed wiring only.

CONNECTIONS

MOUNTING OF THE RECEIVER

INSTALLATION -THERMOSTAT

Recommended locations for your thermostat.
To ensure that your thermostat provides accurate readings and controls effectively, it must be installed approximately 1.5 m above floor level on an inside wall, away from direct sunshine and any other sources of heat or cold such as radiators, cold draughts, etc.
Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-10NB: In order to ensure proper operation of the product, ensure that the thermostat is not positioned near to an area which could be affected by interference from another source. E.g.: a wireless transmitter or receiver, TV, PC, etc.

INSTALLING BATTERIES

  1. Remove the batteries cover which is placed on the front of thermostat.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-11
  2. Insert the 2 batteries AA supplied.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-112
  3. Replace the batteries cover. Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-15

MOUNTING OF THERMOSTAT

• On the wall

  1. Unscrew the 2 screws under the thermostat.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-16
  2. Remove the wall plate from the thermostat.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-17
  3. Secure the wall plate with the two screws provided using the horizontal and vertical holes.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-18
  4. Replace the thermostat on the wall mounting plate.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-19
  5. Secure the thermostat by screwing the locking screws under the thermostat.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-19

On the table stand

  1. Insert the 2 pins inside the wallplate.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-20
  2. Slide the stand to the right.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-21
  3. Fold the stand and lock it into the wallplate.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-22
  4. Tilt the thermostat according to its placement in the room. 2 tilts are available.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-23

The thermostat and the receiver are not bonded together at the factory. To bond the transmitter and the receiver together, proceed as below:

  1.  Press and hold for 5 seconds the RF test button on the receiver. RF test green light is blinking.Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-24
  2. Within 1 minute, press and hold for 5 seconds the RF test button on the thermostat. Pairing icon is flashing.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-25
  3. Thermostat RF icon and receiver green light are blinking.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-26
  4. Thermostat RF icon and receiver green light will be solid when pairing is complete.Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-27

Note: the receiver is usually located near your boiler.
Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-28

OPERATING STATES OF THE SYSTEM

States of the indicator light Operating states of the thermostat
Green Receiver is connected to the thermostat
Orange System is calling for heat
Red RF Signal has been lost, no connection between thermostat and receiver. In order to re-bond the thermostat and receiver refer to the installation instructions (page 2).

TROUBLESHOOTING

Radio transmission is not working properly:

The radio link between the thermostat and the receiver is lost.

The thermostat does not control properly.

TECHNICAL SPECIFICATIONS

Receiver:

Maximum range in the home: 15m is typical but this varies depending on the building construction eg plasterboard lined with metal foil the number of walls and ceilings that the signal has to pass through and by the surrounding electromagnetic environment. Signal sending: every 10 minutes, maximum time-lag 1 minute after set-point temperature has been changed.

Environment 

N.B: this room thermostat is one part of a complete radio system and will only work with the 230V AC receiver. Radio emitter, frequency from 2.40 to 2.48 GHz.

UKCA
UKCA declaration of conformity: We, Neomitis Ltd, hereby declare under our sole responsibility that the products described in these instructions comply with statutory instruments 2017 No. 1206 (Radio Equipment Regulations), 2012 n”3032 (ROHS) and following designated standards listed below:

 EU declaration of conformity:

We, lmhotep Creation, hereby declare under our sole responsibility that the products described in these instructions comply with the provisions of Directives and harmonized standards listed below:

Electronic room thermostat that controls both the cycle time of the thermostat and the ratio between on and off periods during the same cycle of the heating device, depending on the room temperature. PID control reduces the average water temperature, improves the accuracy of room temperature control and increases system efficiency.

DISPOSAL

The symbol Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-30, affixed on the product indicates that you must dispose of it at the end of its useful life at a special recycling point, in accordance with European Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to the retailer from which you buy the replacement equipment. Thus, it is not ordinary household waste. Recycling products enables us to protect the environment and to use less natural resources.

OVERVIEW

Thank you for purchasing our RT0 RF, wireless digital room thermostat with PID and backlight. It is by listening to your requirements we have created and designed our products to be easy to operate and install. The thermostat is designed to make your life easier by helping you to save energy and money through ease of operation.

Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-31

CONTROLS AND DISPLAY

Thermostat

Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-32

LCD Display

Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-33

SETTINGS

INSTALLING BATTERIES

1- Remove the batteries cover which is placed on the front of thermostat.

2- Insert the 2 batteries AA supplied. Note the cor­ rect polarity according to the engraving on the thermostat when inser­ ting the batteries.

3- Replace the batteries cover.
Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-34 Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-35 Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-35

INITIAL POWER UP

  1. Once batteries are fitted all symbols will be displayed on the LCD screen as shown for two seconds.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-36
  2. After 2 seconds, the LCD will light up and show:
    • The ambient temperature (“C) solid.
    • The icon is Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-37 solid when the heating is turned ON.
    • The setpoint temperature (“C) solid.
    • RF icon flashes.

Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-38

PAIRING PROCEDURE
The thermostat and the receiver are not bonded together at the factory. To bond the transmitter and the receiver together, proceed as below:

  1. Press and hold for 5 seconds the RF test button on the receiver. RF test green light is blinking.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-39
  2. Within 1 minute, press and hold for 5 seconds the RF test button on the thermostat. Pairing icon is flashing.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-40
  3. Thermostat RF ico n and receiver green light are blinking.
    Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-41
  4. Thermostat RF icon and receiver green light will be solid when pairing is complete.

Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-42

OPERATING

TEMPERATURES SETTING
The desired temperature can be set. To set the temperature, turn the dial clo­ ckwise, to increase the temperature, turn the dial counter-clockwise, to decrease the temperature. The default temperature is 20°C (68F).

Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-43

OPERATING STATES OF THE SYSTEM

States of the indicator light  Operating states of the thermostat
Green Receiver is connected to the thermostat
Orange System is calling for heat
Red RF Signal has been lost, no connection between thermostat and receiver. In order to re-bond the thermostat and receiver refer to the installation instructions

OVERRIDE
You can press the OVERRIDE button on the receiver to manually switch ON/OFF if you have a faulty room unit or transmission signal. This will be operate until communication is restored.

Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-44

FACTORY SETTINGS

Setting Factory Setting
Set temperature 2O°c

Note: To restore factory settings, press and hold down this part for more than 3 seconds using the tip of a pen.
All LCD display will be turned ON for 2 seconds and the factory settings will be restored.

Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-45

TROUBLESHOOTING

TECHNICAL SPECIFICATIONS

Please refer to the installing instructions for any informations about batteries life, stan­ dards and product environment.

WHAT IS A ROOM THERMOSTAT

Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-48

… an explanation for householders A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
Turning a room thermostat to a higher set­ ting will not make the room heat up any faster. How quickly the room heats up de­pends on the design of the heating system, for example, the size of boiler and radiators. Neither does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy.
The heating system will not work if a time switch or programmer has switched it off. The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature – say 182C – and then turn it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money. If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have different temperatures in indi­ vidual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs. Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or
table lamps may prevent the thermostat from working properly.

WHAT IS PID

Neomitis -RTE0RFB -WIRELESS- DIGITAL -ROOM- THERMOSTAT-49

REFERENCE

DOWNLOAD MANUAL

Neomitis RTE0RFB WIRELESS DIGITAL ROOM THERMOSTAT Installation Manual

OTHER MANUALS:

Neomitis RTE0RFB WIRELESS DIGITAL ROOM THERMOSTAT Installation Manual

Neomitis-logo

Neomitis RTE0RFB WIRELESS DIGITAL ROOM THERMOSTAT Installation Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)