The MPRT RF consists of a room unit and a relay box. The ROOM UNIT is programmable a room thermostat. It measures the temperature of your room and then controls the heating to maintain the room at the chosen temperature. IMPORTANT: Do not place or fi t the ROOM UNIT where it will be affected by heat from radiators, sunshine, or other heat source. The relay box is wired to your heating equipment by your electrician. The room unit communicates with the relay box by radio waves, thus switching on/off your heating. If your MPRT RF has already been installed you need only follow the section ‘THREE EASY STEPS’, to operate your heating.
On your MPRT unit you set the value of three temperatures, Low, Medium and High. “Low” is typically a night setting, “Medium” an afternoon setting, and “High” a morning and evening setting. Your MPRT will then operate your heating to maintain these temperature settings. Follow steps 1 to 3 below.
SETTING THE CLOCK
SETTING YOUR 3 TEMPERATURES
SETTING YOUR HEATING TIMES
NOTE:
SMART START
“SMART START” varies the start-up times to ensure that the build- ing achieves temperature by the required time. The smart start system is continually learning the temperature rise requirement, delaying the start up of the system, therefore saving energy during milder weather.
SETUP FOR SMART-START.
To toggle the Smart-Start function between enabled and disabled, hold
ONE HOUR OF HIGH TEMPERATURE.
If you press
MANUAL OVERRIDE.
If you hold
DEACTIVATING YOUR HEATING:
If you press
Note:
Provided you deactivate via the MPRTRF, the system will have frost protection at 60C. If the system is to be left shut down for a long period over winter, ensure there is sufficient battery life to maintain protection..
KEYPAD LOCKING.
Hold
RETURN TO FACTORY SETTINGS.
Holding
COPY FUNCTION.
Pressing
HOLIDAY FUNCTION.
Pressing H while holding
SMART-START FUNCTION
The message “SMART START” displayed on the screen indicates that this function is operating. Smart-Start works by switching the heat on in advance – so that the room can warm up. As an example, lets say you get out of bed at 8am and you want the room to be warm at that time. Without Smart-Start you must programme your High temperature for 7am. With Smart-Start you need only programme your High temperature for 8am. Smart-Start will know that you want the room warm at 8am and bring the heating on before that. But Smart-Start is even more intelligent than this. It remembers how cold it was on the previous mornings. Thus, in Winter it might start the heating 1 hour before 7a.m. and in Spring start half an hour before 7a.m. In this way it provides optimum comfort and energy saving.
Note:
In extreme low temperatures and dependant on your heating system capability, the desired temperature set may not be reached by the set time. Thus an earlier higher temperature may need to be set.
Once your Relay Box has been installed, it becomes part of your heating equipment. It operates automatically
REPLACING THE BATTERIES IN YOUR ROOM UNIT.
Dependant on type and manufacturer the batteries in your MPRT RF should last approximately 2 years. When they go low, a battery symbol appears on the LCD screen telling you to replace the batteries.
To access the batteries release the cover from the base by pressing the base at arrow shown above. The batteries are then visible.
NOTE: Changing the battery in 1 minute or less will retain all your settings. If it takes longer than 1 minute, you may have to re-enter your settings.
MYSON CONTROLS
DOWNLOAD MANUALS:
Myson MPRT RF WIRELESS PROGRAMMABLE THERMOSTAT USER INSTRUCTIONS
Myson MPRT RF WIRELESS PROGRAMMABLE THERMOSTAT USER INSTRUCTIONS
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…