Thank you for your confidence in our product. To obtain the best results from your investment, please read these instructions and acquaint yourself with your purchase. Follow the installation procedures carefully, and save these instructions for future reference.
This thermostat can be used with most single-stage 24 Volt hydronic, and radiant underfloor heating applications up to 2 Amps. NOTE: This thermostat is system powered only, and requires 3 wires to the thermostat location for operation: 24V+ Power, 24V- Common, and Heat Activation Signal. This thermostat cannot be used with: 3-wire zone valves (non-self-closing upon power removal), 120/240-volt heating elements, cooling systems, or heat pumps. Ask your dealer for other LUXPRO thermostats to control those systems.
Mercury is considered to be a hazardous material. If this product is replacing a thermostat that contains mercury in a sealed tube, contact your local waste management authority for instructions regarding recycling and proper disposal. It may be unlawful in your state to place it in the trash.
TOOLS YOU MAY NEED
Screwdrivers, wire strippers, wire cutters, and possibly a drill with assorted bits (typically for new installations only).
INCLUDED FLOOR/SLAB TEMPERATURE SENSOR
This thermostat kit contains a floor/slab temperature sensor that gets wired to the thermostat baseplate. The floor/slab sensor is an important component in the system, to properly control the heating output commands. The thermostat uses information from both the onboard internal room/air sensor and also the wired remote floor/slab sensor during temperature control. The thermostat controls the room/air temperature to your desired setpoint value using the heat provided by the floor, but also maintains the floor/slab temperature to within the MIN/MAX thresholds that you would like it to remain within. The recommended location in the slab for this sensor is inside of an extra piece of radiant floor tubing at least 3-4 ft. (90-120 cm) in from the perimeter of the slab, with this tube at a depth of approximately 1 in. (25 mm) below the finished surface of the slab. Please ensure that the sensor is positioned at least 8 in. (20 cm) from any heated water tubing within the floor/slab, so that the true temperature of the slab is being measured.
REMOVAL OF OLD THERMOSTAT
THERMOSTAT MOUNTING LOCATION
On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, please follow these general guidelines:
INSTALLATION OF NEW THERMOSTAT
COMPLETE THE INSTALLATION
FRONT PANEL CONTROLS
COMFORT MODE
This is the normal operating mode for regular heating temperature control. To view the current COMFORT set temperature, select COMFORT mode with the mode button and press either the UP or DOWN button one time. You can adjust the set temperature by continuing to press either the UP or DOWN button to the desired target value. The available room/air temperature setting values while in COMFORT mode are between 40°F (5°C) and 86°F (30°C) degrees. Save the changes by pressing the OK/INFO button.
ECO (ENERGY SAVING) MODE
ECO mode uses a lower target set temperature to save energy while you are away, which you can adjust separately. To view the current ECO set temperature, select ECO mode with the mode button, then press the SET button. You can adjust the ECO mode set temperature by pressing UP or DOWN to the desired target value. Save the changes by pressing the OK/INFO button.
NOTE: The available range of the ECO mode set temperature is linked to and based upon, the current COMFORT mode target set temperature. The ECO mode set temperature can range from 2°F (1°C) degrees to 10°F (5°C) degrees LESS than the current COMFORT mode target set temperature.
ECO MODE EXAMPLE: if the present COMFORT temperature is 75°F (24°C) degrees, the ECO set temperature can be from 65°F (19°C) to 73°F (23°C) degrees.
FREEZE PROTECT MODE
This mode is intended to be used during times of vacancy or non-use, to prevent the floor/slab from getting close to freezing temperatures. To view the current FREEZE PROTECT set temperature, select FREEZE PROTECT mode with the mode button, then press the SET button. You can adjust the FREEZE PROTECT mode set temperature by pressing UP or DOWN to the desired target value. The available setting values while in FREEZE PROTECT mode are between 40°F (5°C) and 50°F (10°C) degrees. Save the changes by pressing the OK/INFO button.
STANDBY (OFF) MODE
This mode is used when you want to completely turn off the heating output signal. The thermostat does not protect the system from freezing when placed into STANDBY mode.
NOTE: there are some menu items which are set to fixed values, and are NOT adjustable for this particular version of the thermostat. The non-adjustable menu items will be listed below as “fixed value, not adjustable”, will not respond to UP/DOWN button presses, please use the OK/INFO button to advance to the next available setting. This thermostat has two configuration menu areas for adjusting how the thermostat will operate the heating output:
INSTALLER SETTINGS MENU
TO ACCESS THE INSTALLER SETTINGS MENU: Place the thermostat into STANDBY mode. Hold both the SET and UP buttons for at least 5 seconds, until the screen changes. The menu starts with item #01 below, and is advanced to each following item pressing the OK/INFO button. The options for each item are changed using the UP or DOWN buttons. To exit, keep pressing the OK/INFO button until the thermostat returns back to the normal STANDBY mode screen.
TO ACCESS THE EXPERT SETTINGS MENU: Place the thermostat into STANDBY mode. Hold both the SET and UP buttons for approximately 10 seconds until the screen changes for a second time, after the INSTALLER menu content appears. The menu starts with item #01 below, and is advanced to each following item pressing the OK/INFO button. The options for each item are changed using the UP or DOWN buttons. To exit, keep pressing the OK/INFO button until the thermostat returns back to the normal STANDBY mode screen.
WARNING:
When in STANDBY MODE, the thermostat does not provide freeze protection. There is no low-temperature limit for the Floor/Slab temperature. If the system has not been adequately prepared for low temperatures, damage from freezing can result.
The Keypad Lockout feature prevents accidental setting changes, and helps to deter unauthorized users from tampering with the temperature settings.
TO LOCK THE FRONT PANEL BUTTONS: Hold both the UP and DOWN buttons together for at least 3 seconds, and a padlock icon will appear in the lower right corner of the display screen.
TO UNLOCK THE FRONT PANEL BUTTONS: Hold both the UP and DOWN buttons together for at least 3 seconds, and a padlock icon should disappear from the display screen.
INSTALLER MANUAL OUTPUT CONTROL – SYSTEM TEST
This thermostat has a manual system test mode that can be used during installation or system diagnosis, to force the output ON/OFF in real time with no delays.
TO ACCESS THE MANUAL TEST MODE: First place the System Mode into STANDBY, and then press both the SET and OK/INFO buttons together at the same time. While in Test Mode, the display will show “TEST”. The heating output command can be toggled “ON” with the UP button, and “OFF” with the DOWN button.
TO EXIT THE MANUAL TEST MODE: Press the OK/INFO button and the thermostat will return back to the normal STANDBY mode screen.
If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please contact our Technical Assistance department at 856-234-8803 during regular business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday. You can also receive technical assistance online anytime day or night at
http://www.luxproproducts.com. Our web site offers you answers to the most common technical questions, and also permits you to email your questions to our technical support staff at your convenience.
If this unit fails because of defects in materials or workmanship within three years of the date of original purchase, LUX will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to three years from the date of original purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the location from which the purchase was made, along with proof of purchase. Please refer to “TECHNICAL ASSISTANCE” before returning thermostat. Purchaser assumes all risks and liability for incidental and consequential damage resulting from installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state. Applicable in the U.S.A. and Canada only.
WIRING DIAGRAMS
WATER VALVE RECEIVES COMMON POWER FROM TRANSFORMER
WATER VALVE RECEIVES COMMON POWER FROM THERMOSTAT
FLOOR/SLAB SENSOR TO THERMOSTAT (ORDER DOES NOT MATTER)
Download Manual
LUXPRO P2000F Non-Programmable Thermostat Installation Manual
Other manuals:
LUXPRO P2000F Non-Programmable Thermostat Product Specifications
LUXPRO P2000F Non-Programmable Thermostat Installation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…