In this guide, we will describe the advanced installation settings that you can access from KONO Smart’s main menu. We recommend that an HVAC service professional uses these settings to fine-tune your thermostat’s performance for your home.
You can access the installation settings by going to the main menu and selecting the gear icon. You will see “IS” on the screen and will be prompted
to select “yes” or “no”. Select “yes” to access the installation settings.
There are three ways to exit the settings:
You will first see your current system type and configuration – confirm by pressing the knob
and then you will begin navigating through the available settings.
Use this setting to select your preferred temperature format.
KONO Smart is factory calibrated, but you can use this setting to adjust the temperature sensor for your home. The screen will alternate between your calibration temperature and the offset value – to remove calibration, make sure that the offset value is set to 0.
KONO Smart uses terminal detection to identify your system type and you can use this installation setting to view and change the available modes. Use this setting to view and/or change the different modes available depending on your system type. Rotate the knob to see various options and configurations for your system.
Use this setting to set a maximum temperature limit for your heating system. The limit can be as high as 90F (32C) or as low as 60F (15C).
Use this setting to set a minimum temperature limit for your cooling system. The limit can be as high as 75F (24C) or as low as 45F (7C).
Use this setting to modify the system type. The available options include Gas Furnace, Electric Furnace, Boiler (No Fan) and Heat Pump. See step 07 below for additional options when selecting Heat Pump.
If you selected heat pump during #6, you will then have to select your valve type in #7. Select O or B depending on your valve type. B will energize the B/O terminal in heat mode and O will energize the B/O terminal in cool mode.
Use this setting to set a standby time so that your HVAC systems can safely and efficiently switch on and off. You can either select a 5-minute or a 2-minute off time. During normal operation, the hourglass icon indicates that the minimum off time is temporarily preventing your heating and cooling system from turning on.
Use this setting to set a swing value. Your swing setting determines how far the ambient temperature can deviate from the set temperature before KONO Smart turns on your heating or cooling system. You can select 0, .25°, .5°, 1° or 2.25°.
Use this setting to set a value that your thermostat will use to decide when to turn on your second stage of heating. You can select Off, 1, 2, 3, 4 or 5.
Use this setting to set a value that your thermostat will use to decide when to turn on your second stage of heating. You can select Off, 1, 2, 3, 4 or 5.
Use this setting to choose between 12-hour am/pm time display or a 24-hour time display.
Use this setting to choose between a backlight auto-off setting of 10 seconds or an always-on backlight. When the backlight is turned off the display will not be visible. Press the knob to turn on the display.
Use this setting to turn the ‘Dual Fuel’ option ON or OFF. When set to ON, the balance points defined in menus 15 and 16 will be used to determine use of a compressor and auxiliary heat stages. When set to OFF, the outside air temperature will not be used to determine staging rules.
Use this setting to specify an outdoor air temperature above which your auxiliary heat source will be disabled. If the outdoor temperature goes above this set point, only the compressor heat source will be used.
Use this setting to specify an outdoor air temperature below which your compressor will be disabled. If the outdoor temperature goes below this set point, only the auxiliary heat source will be used.
Use this setting to turn on and set a value for your air filter’s lifespan. You’ll then be able to check its remaining lifespan in the fan settings submenu. (You can select Off, 30, 60, 90, 120, 180 or 365 days).
Use this setting to temporarily disable the minimum on/ off time protection. If you set compressor bypass protection to ‘yes’ then your system will switch heating and cooling on/off without waiting for the minimum on/off time.
Use this setting to initiate a factory reset and to setup your KONO Smart from scratch.
Lock: Press and hold the knob for 10 seconds on the main run screen to lock local control of KONO Smart. When locked, press and hold the knob for 10 seconds to unlock.
Power Cycle: Remove KONO Smart from its base and locate the black reset button on the back of the thermostat. Press and hold this button for 3 seconds to fully power cycle the device.
EMER Heat: If you have a Heat Pump system with stage 2 (auxiliary) heat enabled, you can select EMER heat from the mode menu. When this is enabled, the thermostat will not use the compressor heating stage and will use the auxiliary heating stage as the only heat source.
For wiring diagrams, please reference the appendix section of the KONO Smart Installation Manual
We’re here to help! Please contact our customer support team for assistance:
PHONE: 856.234.8803
LIVE CHAT: LuxProducts.com/support
EMAIL: techsupport@luxproducts.com
VIDEOS: LuxProducts.com/Videos
SUPPORT HOURS: 8 am to 6 pm EST, Monday – Friday
Download Manual
Lux KONO Smart THERMOSTAT Installation Settings Guide
OTHER MANUAL
Lux KONO Smart THERMOSTAT User Manual
Lux KONO Smart THERMOSTAT Operations Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…