Technical data | ||
Supply voltage: | 230V 50/60Hz | |
Power consumption: | 1 W | |
Relay output: | 1 changeover contact 8A 250V~ cos f = 1 | |
Accuracy: | ± 1 s /day, day under typical installation conditions | |
single strand | multi strand | |
Wire cross-sections: | 1,5…4 mm2 | 1,5…2,5 mm2 |
Programs (saved by EEPROM) 4x predefined, 1x individual | ||
Running reserve: | 100h for all settings | |
Range of adjustment: | +7°C … +30°C | |
Frost protection temperature: | +7°C | |
Storage temperature: | – 10°C to +60°C | |
Ambient temperature | – 5°C to +50°C | |
Operating principle: | Typ 1.B. EN 60730-1 | |
Energy class | IV = 2%, EU 811/2013 |
Softkeys
PROGRAMS
Reset
Manual regulation
Modifies the setpoint directly in steps of 0,5 °C; this action doesn’t affect the chosen mode. With the next automatic switching, either due to a program or because of a return to the auto mode, the setpoint is set back to the pre-selected value.
Select language
Time, date and summertime (Daylight saving time)
Comfort time when present
Wall compensation
The wall compensation enables the difference to be adjusted if the temperature values differ from the room temperature.
Contrast/brightness adjustment
Modify programs Changes ON/OFF-times
Create program 5
Download manual:
Legrand 076721 Thermostat programmable User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…