ELECTRIC SHOCK OR FIRE HAZARD
READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS, AND SAFETY DA TD AVOIDS PROPERTY DAMAGE AND PERSONAL INJURY
READ CAREFULLY – These instructions will help prevent difficulties that might arise during thermostat installation. Studying the instructions first may save considerable time and money later. Observing the following procedures will keep installation time to a minimum. Save these instructions for future use.
FUNCTIONS AND FEATURES Breaker
This Thermostat has been designed to control fan-forced and radiant line voltage electric heaters.
The ClearTouch K322E combines user-friendly touch-sensitive buttons with a sleek modern design. Offering simple non-programmable control of your comfort.
DANGER
ELECTRIC SHOCK OR FIRE HAZARD READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS, AND SAFETY DATA TO AVOID PROPERTY DAMAGE AND PERSONAL INJURY The installation of the thermostat must comply with the applicable local and/or national electrical code and utility requirements. This installation should be performed by a qualified electrician where required by law. Ensure that all wiring connections to the thermostat are correct and tight to prevent electrical shorts. Use the appropriate wire to meet local and national electrical codes for rated power consumption
WARNING!
Warning: Turn OFF the power at the circuit breaker before Installing. Installation to be performed by a qualified electrician or authorized technician. Refer to thermostat and heater load specifications before installation of the thermostat to see if it can handle the amp load. The maximum this thermostat can run is 1800W @120V or 3600 W@ 240 V (15A). Install unit in a grounded metal or plastic wall junction box, indoors 4 ½’ to 5′ above the floor. Avoid any area where it can come in contact with external sources of heat and cold. This includes plumbing pipes, direct sunlight, a T.V set, lamps, and drafts from a door or window, as this may cause inaccurate temperature readings. The most convenient place is above the light switch. Not for Outdoor use.
WIRING INSTRUCTIONS
Caution: Turn off the power at the circuit breaker before performing any work on the electrical connections. None of the electrical connections must be live until the installation has been completed and the housing is closed. Only a qualified electrician or authorized technician are permitted to open the terminal box.
Wiring requires a Phillips screwdriver
(Optional) Connection to a Slave Relay (K312RELAY}
If the heating area requires the addition of a Slave Relay, connect the low voltage wire for an auxiliary Slave Relay (K312RELAY) into terminals 5 & 6 (Relout) on the back of the power board to add a zone. See the drawing below Install the power board into tl1e electrical box with the 2 screws provided, and then clip & fasten the front Display Panel into place with the bottom screw. Make sure your K322E thermostat is COMPLETELY RECESSED into the junction box and flush with the wall. NO WIRES SHOULD BE EXPOSED outside
the metal or plastic junction box
Safety Information
Control Wiring
ON/OFF Settings
ON From the OFF status, slide the ON/OFF side switch up to turn the unit on. The time clock, actual probe temperature, working mode, and output status will be displayed on the screen.
OFF From the ON status, slide the ON/OFF switch down to turn the unit off. It will display OFF and all outputs will be open.
In any mode, press the
Press
After entering into the interface of Set Temp settings, press the 0 or 0 buttons for 3 sec. to decrease/ increase the temperature continuously.
Once completed, press the CONFIRM button on the right side of the thermostat to confirm changes or wait for 1 Os without any operation to save the values an return to the normal working interface automatically.
Keypad Lock
In the normal working interface, press
Room Temperature Control Mode
When the icon
Remote Control of Thermostat
When there is a remote control signal input, the Remote icon (bar) blinks; when the detected indoor temperature is below the set temperature by -2°C -4F), electrical heating will be turned on, and the icon
Sensor Failure
When the sensor fails to work, the error icon EEE will be displayed on the screen. The output relay will open. The heating output will stop. Replace sensor.
Configuration of User Parameters (Hidden Menu)
When the thermostat is OFF: Press and hold the CONFIRM button to enter into the setting interface. Default values and options are defined below:
King Electric K302PE electronic non programmable thermostat Installation Instruction
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…