Icons used in this guide:
Thank you for purchasing one of our Speedfit Aura Wireless Thermostat models. It must be used with the JGCO Wireless Coordinator. The Wireless Coordinator allows communication with other devices in the Aura Wireless system range including wiring center, Wireless boiler receiver and Wireless TRV.
Product Compliance.
These products are CE compliant and meet the following European
Directives:
Safety Information. Use in accordance with the regulations. The JG Aura JGSTATW1/W2 is to be used for room control of heating and hot water systems inside buildings.
These instructions are applicable to the Aura models stated on the front cover of this Instruction Manual only.
Warning. This product must be 230 AC fitted by a competent person. Installation must comply with the guidance, standards and regulations applicable to the location where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to prosecution, injury or death.
Sources of danger. The thermostat must be disconnected from mains supply before removing the cover
Emergency. Switch off the voltage to the individual thermostat, wiring centre or complete system
Warning. Always isolate the AC Mains supply before installing or working on any components that require 230v AC 50Hz supply.
Installer parameter settings.
JG Aura wireless thermostats are equipped with an Installer Parameter section (see website). This must only be entered by the installer or a competent person. Changing these parameters can have a serious effect on your heating system
Rear of unit
Power Terminals 230v AC.
Used for supplying power to the unit. 230v supply can be sourced from the wiring centre or any convenient 3amp fused supply.
Probe / Hot Water Cylinder
Terminals. Can be used for external Air or Floor probe when configured as thermostat. Can also be used for Cylinder thermostat connection when configured as a Timer
REAR UNIT
Sensor Terminals.
Can be used for an external Air or Floor sensor when configured as thermostat. Can also be used for Cylinder thermostat when configured for HW.
Coordinator set-up
To commence system installation, press and hold the button for 5 seconds. The button will start to flash red indicating that the Zigbee network is ready to accept JG Aura devices. For full Coordinator instructions please see seperate literature or go on line to speedfitUFH.co.uk
The JGBR default setting is RX1 (Wireless Boiler Receiver). In this mode, the JGBR will switch on the boiler in response to a call for heat. To set as a wireless receiver, switch to RX2. The wireless receiver will be paired to just one chosen thermostat on the network. This thermostat will switch the wireless receiver when there is a call for heat
Identifying the Wiring Centre
After setting up, the Coordinator will assign the Wiring Centre a number. This is because more than 1 Wiring Centre may be used on a project. Pressing the network button will illuminate the relevant number. The example shown is for Wiring Centre 1. If 1 and 2 are lit it would be Wiring Centre 2.
Programmable Room Thermostat paired with Wireless Wiring Centre
Programmable Room Thermostat paired with Wireless TRV
Programmable Room Thermostat paired with Wireless Boiler Receiver (RX1)
Programmable Room Thermostat paired with Wireless Receiver (RX2)
John Guest Speedfit Limited
Download Manual:
Johnguest JGSTATW2W Aura 230v Wireless Thermostats Quick Set-up Guide
Johnguest JGSTATW2W Aura 230v Wireless Thermostats Quick Set-up Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…