Johnguest JGSTAT4W 240v Wired Programmable Room Thermostat  FEA

Johnguest JGSTATW2W Aura 230v Wireless Thermostats Quick Set-up Guide

Johnguest-JGSTAT4W-240v-Wired-Programmable-Room-Thermostat-product

Johnguest JGSTATW2W Aura 230v Wireless Thermostats 

Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats- PRO

Box contentsJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-1

Icons used in this guide:Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-2

Introduction

Thank you for purchasing one of our Speedfit Aura Wireless Thermostat models. It must be used with the JGCO Wireless Coordinator. The Wireless Coordinator allows communication with other devices in the Aura Wireless system range including wiring center, Wireless boiler receiver and Wireless TRV.Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-3

Product Compliance.
These products are CE compliant and meet the following European

Directives:

  • RoHS2: 2011/65/EU
  • RED: 2014/30/EU
  • Declaration of conformity available at saluslegal.com

Safety Information. Use in accordance with the regulations. The JG Aura JGSTATW1/W2 is to be used for room control of heating and hot water systems inside buildings.

These instructions are applicable to the Aura models stated on the front cover of this Instruction Manual only.

Warning. This product must be 230 AC fitted by a competent person. Installation must comply with the guidance, standards and regulations applicable to the location where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to prosecution, injury or death.

Sources of danger. The thermostat must be disconnected from mains supply before removing the cover

Emergency. Switch off the voltage to the individual thermostat, wiring centre or complete system

Warning. Always isolate the AC Mains supply before installing or working on any components that require 230v AC 50Hz supply.

Installer parameter settings.
JG Aura wireless thermostats are equipped with an Installer Parameter section (see website). This must only be entered by the installer or a competent person. Changing these parameters can have a serious effect on your heating system

Terminal connections (JGSTATW2) – 230v powered

Rear of unit

Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-4

Power Terminals 230v AC.
Used for supplying power to the unit. 230v supply can be sourced from the wiring centre or any convenient 3amp fused supply.Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-5

Probe / Hot Water Cylinder
Terminals. Can be used for external Air or Floor probe when configured as thermostat. Can also be used for Cylinder thermostat connection when configured as a Timer

Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-6

Terminal connections (JGSTATW1)

REAR UNIT

Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-7

Sensor Terminals.
Can be used for an external Air or Floor sensor when configured as thermostat. Can also be used for Cylinder thermostat when configured for HW.

Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-8

Coordinator set-up
To commence system installation, press and hold the button for 5 seconds. The button will start to flash red indicating that the Zigbee network is ready to accept JG Aura devices. For full Coordinator instructions please see seperate literature or go on line to speedfitUFH.co.ukJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-9JGBR set-up – Wireless Boiler Receiver or Wireless Receiver
The JGBR default setting is RX1 (Wireless Boiler Receiver). In this mode, the JGBR will switch on the boiler in response to a call for heat. To set as a wireless receiver, switch to RX2. The wireless receiver will be paired to just one chosen thermostat on the network. This thermostat will switch the wireless receiver when there is a call for heatJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-10

Identifying the Wiring Centre
After setting up, the Coordinator will assign the Wiring Centre a number. This is because more than 1 Wiring Centre may be used on a project. Pressing the network button will illuminate the relevant number. The example shown is for Wiring Centre 1. If 1 and 2 are lit it would be Wiring Centre 2.Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-11

Programmable Room Thermostat paired with Wireless Wiring Centre

  • Start up screen as shown. Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15
  • No action required.

Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-12

  • Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15
  • Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-45icon flashing to request the number of the Wiring Centre you wish to pair with (see Identifying Wiring Centre – page 9). Use Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-17 to select the required number. Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-13
  • requesting group number. No action needed in this instance. Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15
  • Zone number flashing. Using the Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-17to set the wiring centre zone you want the thermostat to control. Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-14
  • Thermostat returns to home screen and the pairing is finished. Testing: Set thermostat to high temperature and wait for a call for heat. Check that the thermostat is communicating with the correct zone on the paired wiring centre.Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-21

Programmable Room Thermostat paired with Wireless TRV

  • From start up screen pressJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-18
  • Screen will scroll to Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-22
  • No action required
  • Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-23
  • Press Pairing Button on TRV(s) for 10 seconds until pairing light on the TRV starts to flash. Maximum of 6 TRV’s can be paired at the same time
  • Next pressJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-19 arrow on thermostat to start pairing process. Do not press Confirm as it will abort the pairing process and user will have to start again. thermostat only finds 1 to 5 TRV’s it will continue to search until user presses ConfirmJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-24
  • If the maximum 6 TRV’s are found the thermostat will automatically finish pairing and return to the home screen
  • Thermostat returns to home screen. Testing: Set to call for heat. Check TRV’s are opening and Boiler Receiver is receiving the signal. Turn down the thermostat and check TRV’s shut and boiler receiver turns off.Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-25

Programmable Room Thermostat paired with Wireless Boiler Receiver (RX1)

  • Start up screen as shown. Press and hold bottom 3 buttons until next screen is shown
  • Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-26
  • PressJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-46 to scroll to
  • Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-27
  • No action required.
  • Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-28
  • Thermostat returns to home screen. Testing: Set thermostat to high temperature and wait for a call for heat. Check the Wireless Boiler Receiver is receiving the signal and switching on and off.Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-29

Programmable Room Thermostat paired with Wireless Receiver (RX2)

  • Start up screen as shown. Press and hold bottom 3 buttons until next screen is shown.Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-30
  • Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15
  • PressJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-46 to scroll toJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-31
  • Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15
  • No action required
  • Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-32
  • Thermostat returns to home screen. Testing: Set thermostat to high temperature and wait for a call for heat. Check the Receiver is receiving the signal and switching on and off. If there is also a boiler receiver fitted to the network check that this is responding

Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-33Hot Water Timer paired with Wiring Centre

  • Start up screen as shown. Hold bottom 3 buttons to scroll to screen
  • PressJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-46 to scroll to Hot Water Timer screenJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-30
  • Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15
  • No action needed.Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-31
  • Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-15
  • Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-45icon flashing to request the number of the Wiring Centre to pair with (see Identifying Wiring Centre – page 9). Use Johnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-17to select the required number. Press CONFIRMJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-32
  • Hot Water Timer displays home screen. Testing: Set timer to [ON] and check that Hot Water Timer LED is lit on wiring centreJohnguest- JGSTATW2W- Aura- 230v- Wireless -Thermostats-33

John Guest Speedfit Limited

  • Horton Road, West Drayton, Middlesex UB7 8JL, England.
  • Tel: 01895 449233
  • Fax: 01895 420321
  • speedfitUFH.co.uk
  • Technical Help Desk: 01895 425333

Reference

Download Manual:

Johnguest JGSTATW2W Aura 230v Wireless Thermostats Quick Set-up Guide

Johnguest JGSTATW2W Aura 230v Wireless Thermostats Quick Set-up Guide

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *