HALO HEAT & SYSTEM 2-ZONE EXTENSION
To install Halo with older boilers further details can be found at idealheating.com This installation guide is designed to work alongside the installation guide from either the Halo Heat & System RF (222141) or the Halo Heat & System Wi-Fi (222143). This guide will advise you on how to install and pair the Halo control unit for Zone 2. The Halo Heat & System 2-Zone Extension kit must be installed by a competent person with the appropriate safety qualifications. Please read the instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. These instructions are applicable to the Ideal Boiler models stated and must not be used with any other make or model of boiler. This product must be installed to all applicable standards. Halo Heat & System RF is a non-connected control (control is via the Halo Heat & System unit only). Halo Heat & System Wi-Fi is a wireless heating control that is connected to the internet. You can download the Halo app on Google Play or the Apple app store. You will not have to pay to use the app. For more information on the features in your Halo app visit the Help section of the app or idealheating.com. If you have purchased or are upgrading a Halo Heat & System RF (non-connected control) you can upgrade this to an internet heating control by downloading the Halo app and following the steps in the app to connect your Halo control. You will be required to pay a connection fee to upgrade to app-controlled heating.
The Halo Heat & System 2-Zone Extension uses wireless Zigbee communication from the Smart Interface to the Halo PRT up to a maximum distance of 30 meters. Occasionally house constructions and materials can reduce this communication range and it is advisable, where possible, to try and avoid directing communications through metal frames or solid concrete walls. If the distance between the Halo PRT and Smart Interface is greater than 30 meters or the install location is challenging, consider using the Zigbee Booster (UIN 221132), further details available at idealheating.com
This is a simplified diagram of how the Halo units, Smart Wiring Centre and Smart Interface communicate. Some wiring and pipework has been omitted for clarity.
TOP TIP: For a robust signal between units, where possible, ensure that the line of communication between the Smart Interface and other units is not through any stone or metallic object
solid and metallic objects will reduce maximum distance
The Halo can be either wall mounted or desk mounted
PAIRING OF THE HALO – ZONE 1
PAIRING OF THE HALO – ZONE 2
Use the “Identify” function to confirm successful pairing has taken place. Short press on the Pair button on the Smart Interface. Press Pair button again to exit “Identify” function. | Zigbee LED on Smart Interface flashes green | |
Halo home screen flashes to indicate successful pairing | ||
Zigbee LED on Smart Wiring Centre flashes green | ||
Halo is positioned in the homeowners chosen location if desk mounted. | ||
Check RSSI (Received Signal Strength Indication) of the Zigbee wireless connection via support page on the PRT (access via the menu). | Target RSSI between 0 and -65 and text green | |
Check RSSI (Received Signal Strength Indication) of the Zigbee wireless connection and the Wi-Fi connection via the support information in the Halo app. (Wi-Fi only) | Target RSSI between 0 and -65 and text green | |
On the Halo set the mode to AUTO then increase the temperature to 30°C (repeat using Halo app if applicable). Note: The boiler will only fire once the zone valve is in the fully open position. | Flame icon ON | |
Heating zone on Smart Wiring Centre OFF | ||
Boiler ON | ||
Boiler LED on Smart Interface ON (Green) | ||
On the Halo set the heating mode to AUTO then decrease the temperature to 5°C (repeat using Halo app). | Flame OFF | |
Heating zone on Smart Wiring Centre OFF | ||
Boiler OFF | ||
Boiler LED on Smart Interface OFF | ||
On the Halo set the hot water mode to ON (repeat using Halo app). Note: The boiler will only fire once the zone valve is in the fully open position. | Hot water ON (icon turns orange) | |
Hot water zone Smart Wiring Centre ON | ||
Boiler ON | ||
Boiler LED on Smart Interface ON (Green) | ||
On the Halo set the hot water mode to OFF (repeat using Halo app). | Hot water OFF (icon turns white) | |
Hot water zone Smart Wiring Centre OFF | ||
Boiler OFF | ||
Boiler LED on Smart Interface OFF |
Use the “Identify” function to confirm successful pairing has taken place. Short press on the Pair button on the Smart Interface. Press Pair button again to exit “Identify” function. | Zigbee LED on Smart Interface flashes green | |
Halo home screen flashes to indicate successful pairing | ||
Zigbee LED on Smart Wiring Centre flashes green | ||
Halo is positioned in the homeowners chosen location if desk mounted. | ||
Check RSSI (Received Signal Strength Indication) of the Zigbee wireless connection via support page on the PRT (access via the menu). | Target RSSI between 0 and -65 and text green | |
Check RSSI (Received Signal Strength Indication) of the Zigbee wireless connection and the Wi-Fi connection via the support information in the Halo app. (Wi-Fi only) | Target RSSI between 0 and -65 and text green | |
On the Halo set the mode to AUTO then increase the temperature to 30°C (repeat using Halo app if applicable). Note: The boiler will only fire once the zone valve is in the fully open position. | Flame icon ON | |
Heating zone on Smart Wiring Centre OFF | ||
Boiler ON | ||
Boiler LED on Smart Interface ON (Green) | ||
On the Halo set the heating mode to AUTO then decrease the temperature to 5°C (repeat using Halo app). | Flame OFF | |
Heating zone on Smart Wiring Centre OFF | ||
Boiler OFF | ||
Boiler LED on Smart Interface OFF | ||
On the Halo set the hot water mode to ON (repeat using Halo app). Note: The boiler will only fire once the zone valve is in the fully open position. | Hot water ON (icon turns orange) | |
Hot water zone Smart Wiring Centre ON | ||
Boiler ON | ||
Boiler LED on Smart Interface ON (Green) | ||
On the Halo set the hot water mode to OFF (repeat using Halo app). | Hot water OFF (icon turns white) | |
Hot water zone Smart Wiring Centre OFF | ||
Boiler OFF | ||
Boiler LED on Smart Interface OFF |
DOWNLOAD MANUAL
Ideal Halo 222145 Programmable Thermostat Installation Guide
Ideal Halo 222145 Programmable Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…