Thermostatic Radiator Valves (TRVs) sense the air temperature around them and regulate the flow of water through the radiator which they are fitted to. They do not control the boiler.
They should be set at a level that gives you the room temperature you want. These settings may have to be different in each room, and you should set the TRVs to suit each room and then leave them to do their job.
Turning a TRV to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the boiler size and setting, and the radiator size. Turning a TRV to a lower setting will result in the room being controlled at a lower temperature, and saves energy. TRVs need a free flow of air to sense the temperature so they must not be covered by curtains or blocked by furniture.
Mode setting
Press M button to choose Manual mode/Away mode/PRG mode.
Press and hold P button for 5s, set the clock (Min-Hour-Weekday) by pressing UP and DOWN button, each press of P button will go to next item setting.
After finish the clock setting, press P to go to PRG schedule setting. Set the schedule (Weekday-Period-Start time-Temp.) by pressing UP and DOWN button, each press of P button will go to next item setting.
Default Setting:
| Period | 1 | 2 | 3 | 4 | 5 | 6 | ||||||
| Time | Temp. | Time | Temp | Time | Temp | Time | Temp | Time | Temp | Time | Temp | |
| 12345(Mon.~Fri.) | 6:00 | 25℃ | 8:00 | 20℃ | 11:30 | 25℃ | 12:30 | 20℃ | 17:00 | 25℃ | 22:00 | 20℃ |
| 6(Sat.) | 8:00 | 25℃ | 11:30 | 20℃ | 12:30 | 25℃ | 17:00 | 20℃ | 22:00 | 25℃ | 23:30 | 20℃ |
| 7(Sun.) | 8:00 | 25℃ | 11:30 | 20℃ | 12:30 | 25℃ | 17:00 | 20℃ | 22:00 | 25℃ | 23:30 | 20℃ |
Open window detect function (OWD function)
When the Open Window mode is enabled in the parameter setting, the system will automatically stop heating when it detects a sudden drop of room temperature (2°C in 15 minutes as default). This is normally caused when a window or door is opened without turning off the heating device.
The device will return to the previous mode of operation after 30mins, then OP disappear. Pressing any button will exit OWD function during the heating off period.
Pair with Host device
Turn off the thermostat, Press and hold M and UP buttons for 3s, until it shows item 01, each press of M button will go to next item setting, adjust the range by using UP and DOWN button.
| Menu 01 | Description Temp. calibration for internal sensor | Range -8 ℃~8 ℃ | Default Value 0℃ | ||
| 02 | Set Point Max. | 5 ℃ ~35℃ | 35 ℃ | ||
| 03 | Set Point Min. | 5 ℃ ~35℃ | 5 ℃ | ||
| 05 | Frost Protection Temp. | 5 ℃ ~15℃ | 5 ℃ | ||
| 10 | Display | 0: Room temp. 1: SET temp. | 0 | ||
| 12 | Open window detect function | 1: ON | 0: OFF | 0 | |
| 13 | OWD Detect Time | 2~30mins | 15mins | ||
| 14 | OWD Drop temp. select (within detect time) | 2.3.4’C | 2 ‘C | ||
| 15 | OWD Delay time select (Return to previous working status) | 10~60min | 30mins | ||
| 17 | Factory reset | 0: No | 0 | ||
| 1: Yes, and then press On/off button for 5s, wait until thermostat restart | |||||
| 18 | Software version | ||||
| 19 | Software version | ||||
| 31 | Battery voltage | Unit: 10mv | |||
| 32 | PID | P-band select | 2 ℃ ~10℃ | 7℃ | |
| 33 | PID | I-time select | 30~90min | 30min | |
DOWNLOAD MANUALS:
Hotowell HTW-31RT Programmable Radiator Thermostat User Manual
Hotowell HTW-31RT Programmable Radiator Thermostat User Manual
Amex Casino United Kingdom Instead of free spins, you do well and have winnings that…
Best Online Casino For Roulette Time and Again is an HTML5 title, best online casino…
Fastest Payout Online Casinos Bally Wulff is known for their amazing classic slots and Back…
Bison Casino No Deposit Bonus Codes For Free Spins 2026 One reels 1 and 5…
Casinos With Fast Payouts Sky Queen is a medium to high volatility slot offering an…
European Roulette Guide Uk There is a 30x wagering requirement in place on the deposit…