This smart thermostat has been developed to be able to switch electric and conventional heating systems on and off using a set temperature and time remotely at anytime anywhere.
Sender Power Supply | – 2*AAA battery | Backlight | – White |
Receiver Load current | – 230Vac/Max 10A | Sensor | – NTC 10K, 3950ohms at 25℃ |
Set Point Range | – 5~35℃ | Accuracy | – ± 0.5℃ (step control by +0.5℃) |
Ambient | – 0~50℃ | Protection Class – IP30 | |
Relative Humidity | – 85% | Housing | – ABS to UL94-5 fire retardant plastic |
RRG. Setting
Long press P button to enter PRG setting. The weekday is fixed from Monday to Sunday(1~7), each day have 4 periods(1~4). Each press of P button can into next item setting. The time and temperature of each period i can be set in following steps.
Default Setting
Period | 1 | 2 | 3 | 4 | ||||
Time | Temp | Time | Temp | Time | Temp | Time | Temp | |
12345(Mon.~Fri.) | 7:00 | 22℃ | 8:30 | 19℃ | 17:00 | 22℃ | 22:00 | 19℃ |
6(Sat.) | 8:00 | 22℃ | 8:30 | 22℃ | 17:00 | 22℃ | 22:00 | 19℃ |
7(Sun.) | 8:00 | 22℃ | 8:30 | 22℃ | 17:00 | 22℃ | 22:00 | 19℃ |
Hour/Date Setting
Open Window Detection Function
When the Open Window mode is enabled in the parameter setting, the system will automatically stop heating when it detects a sudden drop of room temperature (2°C in 15 minutes as default). This is normally caused when a window or door is opened without turning off the heating device. The device will return to the previous mode of operation after 30mins, then icon‟”OP “disappear. Press any button will exit OWD function during the heating off period
Code Pairing with Sender
Code Pairing with App
Clear all pairing
Long press both code pairing button and On/Off button for 5s, until LED1 and LED2 light. And then light off, which mean the code pairing is eliminated.
Signal Lost
In case the RF and WIFI signal lost/disconnected, LED 2 will flicker slowly
Parameter Setting
Menu 01 | Description Temp. calibration for internal sensor | Range -8 ℃ ~8 ℃ | Default Value 0℃ |
02 | Set Point Max. | 5 ℃ ~35℃ | 35 ℃ |
03 | Set Point Min. | 5 ℃ ~35℃ | 5 ℃ |
05 | Frost Protection Temp. | 5 ℃ ~15℃ | 5 ℃ |
09 | Dead zone | 0~3℃ | 0℃ |
12 | Open window detect function | 1: Enable 0: Disable | 0 |
13 | OWD Detect Time | 2~30mins | 15mins |
14 | OWD Drop temp. select (within detect time) | 2.3.4‟C | 2 „C |
15 | OWD Delay time select (Return to previous working status) | 10~60min | 30mins |
17 | Factory reset | 0: No | 0 |
1: Yes, and then press On/off button for 5s,wait until thermostat restart | |||
Software version | 5055-02 |
Dimensions
DOWNLOAD MANUALS:
hotowell HTW-31-WKT19-WF Wireless Room Thermostat User Manual
hotowell HTW-31-WKT19-WF Wireless Room Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…